KMParts.com is "THE" source for industrial automation control components

Eaton

EASY-E4-UC-12RC1

Nano Programmable Logic Controller

Eaton

EASY-E4-UC-12RC1

Nano Programmable Logic Controller

Eaton

EASY-E4-UC-12RC1

Nano Programmable Logic Controller

Eaton easy-e4-uc-12rc1 nano programmable interface
  • 6 Basic Devices
  • 8 Expansion Packs Available
  • Available With or Without Displays
  • DIN Rail Mounted
  • Connectable to Ethernet and BUS Systems

6 Base Models Available With or Without Display

Description:

Electronic control relay easy-E4 with supply voltage 12 VDC, 24 VDC or 24 VAC. 8 digital inputs with 12VDC, 24VDC or 24VAC are available, of which 4 inputs can also be used as analog inputs and 4 inputs as fast counter. The control relay easy-E4 has 4 relay outputs for 12 - 250VAC or 12 - 240VDC. The control relay is equipped with a display, a clock, an integrated Ethernet interface and screw terminals. This control relay easy-E4 can be extended with the digital input/output extensions of the easyE4 series.

EASY-E4-UC-12RC1

Technical Specifications

Main Specifications

DescriptionEASY-E4-UC-12RC1 Base Unit
Digital Inputs8
Can Be Used as Analog Inputs4
Quantity of outputsRelay: 4
Real time clockIncluded
Display & keypadIncluded
ExpansionsExpandable networkable (Ethernet)
Supply voltage12/24 V DC
24 V AC
SoftwareEASYSOFT-SWLIC/easySoft 7
Connection typescrew terminal
StandardsEN 61000-6-2
EN 61000-6-3
IEC 60068-2-6
IEC 60068-2-27
IEC 60068-2-30
IEC/EN 61131-2
EN 61010
EN 50178
Approvals
Approvals
cULus
Approvals
certificate
CE
Approvals
shipping classification
DNV GL
ApprovalsApprovals DNV GL
Dimensions (W x H x D)71.5 x 90 x 58 mm
Weight0.215 kg
MountingTop-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Connection typescrew terminal
Ethernet
Connections
RJ45 plug, 8-pin
Ethernet
Cable
CAT5
DescriptionEASY-E4-UC-12RC1 Base Unit
Screw terminals
Solid
0.2 - 4 mm2
Screw terminals
flexible
0.2 - 2.5 mm2
Screw terminals
Solid or flexible conductor, with ferrule
0,2 - 2,5 mm2
Screw terminals
Solid or stranded
22 - 12 AWG
Screw terminals
Standard screwdriver
0.8 x 3.5 mm
Screw terminals
Tightening torque
0.5 - 0.7 Nm
Screw terminals
Stripping length
6.5 mm
DescriptionEASY-E4-UC-12RC1 Base Unit
Display - TypeMonochrome
Lines x characters6 x 16
DescriptionEASY-E4-UC-12RC1 Base Unit
Operating ambient temperature-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C
CondensationTake appropriate measures to prevent condensation
LCD display (clearly legible)0 - 55 °C
Storage [ϑ]-40 - +70 °C
relative humidityin accordance with IEC 60068-2-30, IEC 60068-2-78
5 - 95 %
Air pressure (operation)795 - 1080 hPa
DescriptionEASY-E4-UC-12RC1 Base Unit
Protection type (IEC/EN 60529, EN50178, VBG 4)IP20
VibrationsIn accordance with IEC 60068-2-6
constant amplitude 0.15 mm: 10 - 57
constant acceleration 2 g: 57 - 150 Hz
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms18 Impacts
Drop to IEC/EN 60068-2-31 [Drop height]50 mm
Free fall, packaged (IEC/EN 60068-2-32)0.3 m
Mounting positionVertical or horizontal
DescriptionEASY-E4-UC-12RC1 Base Unit
Overvoltage category/pollution degreeIII/2
Electrostatic discharge (ESD)
applied standard
nach IEC/EN 61000-4-2
Electrostatic discharge (ESD)
Air discharge
8 kV
Electrostatic discharge (ESD)
Contact discharge
6 kV
Electromagnetic fields (RFI) to IEC EN 61000-4-30.08 - 1.0 GHz: 10
1.4 - 2 GHz: 3
2.0 - 2.7 GHz: 1 V/m
Radio interference suppressionEN 61000-6-3 Class B
Burstaccording to IEC/EN 61000-4-4
Supply cables: 2
Signal cables: 2 kV
power pulses (Surge)according to IEC/EN 61000-4-5
1 kV (supply cables, symmetrical)
2 kV (supply cables, asymmetrical)
Immunity to line-conducted interference to (IEC/EN 61000-4-6)10 V
DescriptionEASY-E4-UC-12RC1 Base Unit
Clearance in air and creepage distancesnach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Insulation resistanceper EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
DescriptionEASY-E4-UC-12RC1 Base Unit
Back-up of real-time clockBack-up of real-time clock
① Backup time (hours) with fully charged double layer capacitor
② Service life (years)
Accuracy of the real-time clocktyp. ± 2 (± 0.2 h⁄Year) s/day
depending on ambient air temperature fluctuations of up to ± 5 s/day (± 0.5 h⁄year) are possible
DescriptionEASY-E4-UC-12RC1 Base Unit
Accuracy of timing relays (of values)± 0.02 %
Resolution
Range “S”
5 ms
Resolution
Range “M:S”
1 s
Resolution
Range “H:M”
1 min
DescriptionEASY-E4-UC-12RC1 Base Unit
Rated operational voltage [Ue]12/24 DC (-15/+20%)
24 AC (-15/+10%) V
Permissible range [Ue]10.2 - 28.8 V DC
20.4 - 26.4 V AC
Residual ripple≦ 5 %
Protection against polarity reversalyes
Frequency50/60 (± 5%) Hz
Input currentmax. 200 mA at 12 V DC
max. 125 mA at 24 V DC
Voltage dips ≤ 20 ms at 24 V AC
10 ms at 24 V DC
1 ms at 12 V DC ms
Fuse≧ 1A (T) A
Power loss [P]Normally 3 W
Heat dissipation at 24 V DC3 W
DescriptionEASY-E4-UC-12RC1 Base Unit
Number8
Status DisplayLCD-Display
Potential isolationfrom power supply: no
to the memory card: no
to Ethernet: yes
between inputs: no
from the outputs: yes
to expansion devices: yes
Rated operational voltage [Ue]12 V DC
Input voltageCondition 0: ≦ 5 (I1 - I8)
Condition 1: ≧ 8 (I1 - I8) V DC
Input current at signal 11.75 mA (I1 - I4)
0.9 mA (I5 - I8) mA
Deceleration time20 (0 -> 1/1 -> 0, Debounce ON)
type 0.015 (0 -> 1/1 -> 0, Debounce OFF) ms
Cable length100 (unshielded) m
Frequency counter
Note
Notes on this, see under Digital inputs 24 V DC
Incremental counter
Note
Notes on this, see under Digital inputs 24 V DC
Rapid counter inputs
Note
Notes on this, see under Digital inputs 24 V DC
DescriptionEASY-E4-UC-12RC1 Base Unit
Number8
Inputs can be used as analog inputs4 (I5, I6, I7, I8)
Status DisplayLCD-Display
Potential isolationfrom power supply: no
to the memory card: no
to Ethernet: yes
between inputs: no
from the outputs: yes
to expansion devices: yes
Rated operational voltage [Ue]24 V DC
Input voltageSignal 0: ≦ 5 (I1 - I8)
Condition 1: ≧ 15 (I1 - I8) V DC
Input current at signal 13.3 (I1 – I4)
1.8 (I5 – I8) mA
Deceleration time20 (0 -> 1/1 -> 0, Debounce ON)
type 0.015 (0 -> 1/1 -> 0, Debounce OFF) ms
Cable length100 (unshielded) m
Frequency counter
Number
4 (I1, I2, I3, I4)
Frequency counter
Counter frequency
≦ 5 kHz
Frequency counter
Pulse shape
Square
Frequency counter
Pulse pause ratio
1:1
Frequency counter
Cable length
≦ 20 (screened) m
Incremental counter
Number of counter inputs
2 (I1 + I2, I3 + I4)
Incremental counter
Value range
-2147483648 to +2147483647
Incremental counter
Counter frequency
≦ 5 kHz
Incremental counter
Pulse shape
Square
Incremental counter
Signal offset
90°
Incremental counter
Pulse pause ratio
1:1
Incremental counter
Cable length
≦ 20 (screened) m
Rapid counter inputs
Number
4 (I1, I2, I3, I4)
Rapid counter inputs
Value range
-2147483648 to +2147483647
Rapid counter inputs
Counter frequency
≦ 10 kHz
Rapid counter inputs
Pulse shape
Square
Rapid counter inputs
Pulse pause ratio
1:1
Rapid counter inputs
Cable length
≦ 20 (screened) m
DescriptionEASY-E4-UC-12RC1 Base Unit
Number8
Status DisplayLCD-Display
Potential isolationfrom power supply: no
to the memory card: no
to Ethernet: yes
between inputs: no
from the outputs: yes
to expansion devices: yes
Rated operational voltage [Ue]24 V AC
Input voltage (AC = sinusoidal) [Ue]Status 0: ≦ 5 (I1 - I8)
Condition 1: ≧ 14 (I1 - I8) V
Rated frequency50/60 Hz
Input current at signal 1I1 - I4: 3.5 (at 24 VAC/DC)
I5 - I8: 1.8 (at 24 VAC/DC) mA
Deceleration time45/38 (0 -> 1/1 -> 0, debounce ON 50/60Hz)
type 25⁄21 (0 - > 1/1 -> 0, debounce OFF 50/60Hz) ms
Cable length40 (unshielded) m
DescriptionEASY-E4-UC-12RC1 Base Unit
Number4 (I5, I6, I7, I8)
Potential isolationfrom power supply: no
to the memory card: no
to Ethernet: yes
between inputs: no
from the outputs: yes
to expansion devices: yes
Input typeDC voltage
Signal range0-10 V DC
Resolution12 Bit (value 0 - 4095)
Input impedance13.3 kΩ
Accuracy of actual value
two devices from series
± 3 , ± 0.12 V %
Accuracy of actual value
Within a single device
± 2, ± 0.12 V %
Conversion time, analog/digitaleach CPU cycle ms
Input current< 1 mA
Cable length≦ 30, screened m
DescriptionEASY-E4-UC-12RC1 Base Unit
Number4
Outputs in groups of1
Parallel switching of outputs for increased outputNot allowed
Protection of an output relayMiniature circuit-breaker B16 or slow-blow 8 A fuse
Potential isolationSafe isolation according to EN 50178: 300 V AC
Basic isolation: 600 V AC
from power supply: yes
From the inputs: yes
between outputs: yes
to Ethernet: yes
to expansion devices: yes
Contacts
Conventional thermal current (10 A UL)
8 A
Contacts
Recommended for load: 12 V AC/DC
> 500 mA
Contacts
Rated impulse withstand voltage Uimp of contact coil
6 kV
Contacts
Rated operational voltage [Ue]
240 V AC
Rated insulation voltage [Ui]240 V AC
Safe isolation according to EN 50178300 between coil and contact
300 between two contacts V AC
Making capacity
AC–-15, 250 V AC, 3 A (600 ops./h) [Operations]
300000
Making capacity
DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations]
200000
Breaking capacity
AC-15, 250 V AC, 3 A (600 Ops./h) [Operations]
300000
Breaking capacity
DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations]
200000
Filament bulb load
1000 W at 230/240 V AC [Operations]
25000
Filament bulb load
500 W at 115/120 V AC [Operations]
25000
Fluorescent lamp load
Fluorescent lamp load 10 x 58 W at 230/240 V AC
With upstream electrical device [Operations]
25000
Fluorescent lamp load
Fluorescent lamp load 10 x 58 W at 230/240 V AC
Uncompensated [Operations]
25000
Fluorescent lamp load
Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated [Operations]
25000
Switching frequency
Mechanical operations
10 x 106
Switching frequency
Switching frequency
10 Hz
Switching frequency
Resistive load/lamp load
2 Hz
Switching frequency
Inductive load
0.5 Hz
UL/CSA
Uninterrupted current at 240 V AC
10 A
UL/CSA
Uninterrupted current at 24 V DC
8 A
UL/CSA
AC
Control Circuit Rating Codes (utilization category)
B 300 Light Pilot Duty
UL/CSA
AC
Max. rated operational voltage
300 V AC
UL/CSA
AC
max. thermal continuous current cos ϕ = 1 at B 300
5 A
UL/CSA
AC
max. make/break cos ϕ ≠ capacity 1 at B 300
3600/360 VA
UL/CSA
DC
Control Circuit Rating Codes (utilization category)
R 300 Light Pilot Duty
UL/CSA
DC
Max. rated operational voltage
300 V DC
UL/CSA
DC
Max. thermal uninterrupted current at R 300
1 A
UL/CSA
DC
Max. make/break capacity at R 300
28/28 VA
DescriptionEASY-E4-UC-12RC1 Base Unit
Data transfer rate10/100 Mbit/s
ConnectionsRJ45 plug, 8-pin
CableCAT5
DescriptionEASY-E4-UC-12RC1 Base Unit
Static heat dissipation, non-current-dependent [Pvs]3 W
Operating ambient temperature min.-25 °C
Operating ambient temperature max.+55 °C
DescriptionEASY-E4-UC-12RC1 Base Unit
10.2 Strength of materials and parts
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIESMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
DescriptionEASY-E4-UC-12RC1 Base Unit
Supply voltage AC 50 Hz20.4 - 28.8 V
Supply voltage AC 60 Hz20.4 - 28.8 V
Supply voltage DC10.2 - 28.8 V
Voltage type of supply voltageAC/DC
Switching current8 A
Number of analogue inputs4
Number of analogue outputs0
Number of digital inputs8
Number of digital outputs4
With relay outputYes
Number of HW-interfaces industrial Ethernet1
Number of interfaces PROFINET0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Number of HW-interfaces Wireless0
Number of HW-interfaces other1
With optical interfaceNo
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for MODBUSYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Radio standard UMTSNo
IO link masterNo
RedundancyNo
With displayYes
Degree of protection (IP)IP20
Basic deviceYes
ExpandableYes
Expansion deviceNo
With timerYes
Rail mounting possibleYes
Wall mounting/direct mountingYes
Front build in possibleYes
Rack-assembly possibleNo
Suitable for safety functionsNo
Category according to EN 954-1None
SIL according to IEC 61508None
Performance level acc. EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Explosion safety category for gasNone
Explosion safety category for dustNone
Width71.5 mm
Height90 mm
Depth58 mm
DescriptionEASY-E4-UC-12RC1 Base Unit
UL File No. E205091
UL Category Control No. NRAQ/7
North America Certification UL listed
Degree of Protection IEC: IP20, UL/CSA Type: -
DescriptionEASY-E4-UC-12RC1 Base Unit
EASY-E4-UC-12RC1 Dimensions

Product Accessories

Starter Pack
EASY-BOX-E4-UC1 Starter Pack

Starter Pack
EASY-BOX-E4-DC1 Starter Pack

Starter Pack
EASY-BOX-E4-AC1 Starter Pack


Software
EASYSOFT-SWLIC Software


10W Power Supply
PSL10E24RP 10W Power Supply

30W Power Supply
PSL30E24RP 30W Power Supply


60W Power Supply
PSL60E24RP 60W Power Supply

100W Power Supply
PSL100E24RP 100W Power Supply


Spare Parts
PSL100E24RP 100W Power Supply

Memory Card
PSL100E24RP 100W Power Supply