Menu


Moeller PKZM0 Accessories


CURRENT LIMITERS

§ Used to increase the short circuit current ratings of PKZM0-10 and PKZM0-16 to 50 kA @ 600 V AC and PKZM0-20 and PKZM0-25 to 8 kA @ 600 V AC

§ Mounts below or next to PKZM0 motor protector.

CL-PKZ0

SUPPRESSORS AND AUXILIARY CONTACTS

Type

Article Number

Voltage

PKZ0 AC

RC Suppressors

For use with S(E)00-...-PKZ0(...)

DC rated contactor coils are supplied standard with built in surge suppressors

RCSPKZ048

24 - 48 V AC

RCSPKZ0250

110-250 V AC

Varistor Suppressors

For use with S(E)00-...-PKZ0(...)

DC rated contactor coils are supplied standard with built in surge suppressors

VGSPKZ48

24 - 48 V AC

VGSPKZ250

110-250 V AC

VGSPKZ415

380 - 415 V AC

Base for separate mounting

SE00 and S00 contactors can be individually or separately mounted using the EZ-PKZ0 mounting base.  The base can also be mounted on DIN rail (on rails of 7.5 mm or 15 mm heights)

EZ-PKZ0

For use with S(E)00-PKZ0(...)

HI11-S/EZ-PKZ0

Mechanical Interlock

Used to mechanically interlock two S(E)00 contactors, e.g. to build

reversing started combinations.

MVP-PKZ0

For use with S(E)00-PKZ0(...)

Auxiliary Contact Module

Cannot be combined with:

PKZM0-.../S(E)00 equipped with the NHI-...-PKZ0 and/or AGM-...-PKZ0.

H111-S/EZ-PKZ0

For use with S(E)00-PKZ0(...)

 

INSULATED ENCLOSURES

Type

Article Number

Description Degree of Protection For use with

For Motor Protectors

Includes ground terminal connection, smooth sided base with drill starts

CI-K2-PKZ0-NA

Cover with opening dimensioned to accommodate front of motor protector IP 40 UL/NEMA/CSA 1

PKZM0-...

+NHI or AGM

+U or A

+NHI-E

+L-PKZ0 (2 pieces)

CI-K2-PKZ0-NA-G

 

with black/grey handle IP 55 UL/NEMA/CSA 12, 3R

PKZM0-...

+NHI or AGM

+U or A

+NHI-E

+L-PKZ0 (2 pieces)

CI-K2-PKZ0-NA-GR

 

with red/yellow handle for use in emergency stop circuits to VDE 0113 IP 55 UL/NEMA/CSA 12, 3R

PKZM0-...

+NHI or AGM

+U or A

+NHI-E

+L-PKZ0 (2 pieces)

For Motor protector with early make contacts

CI-K2-PKZ0-NA-GV

 

With black/grey handle

(Includes ground terminal connection, smooth sided base with drill starts)

IP 55 UL/NEMA/CSA 12, 3R

PKZM0-...

+NHI or AGM

+U or A

+NHI-E

+L-PKZ0 (2 pieces)

CI-K2-PKZ0-NA-GRV

With red/yellow handler for use in emergency stop circuits to VDE 0113

 

(Includes ground terminal connection, smooth sided base with drill starts)

IP 55 UL/NEMA/CSA 12, 3R

PKZM0-...

+NHI or AGM

+U or A

+NHI-E

+L-PKZ0 (2 pieces)

SVB-PKZ0-C1

 

Padlocking assembly accommodating up to 3 padlocks with a hasp thickness of 3-6 mm for use on main switched to IEC/EN 60 204

 

(Padlockable on the OFF position of the PKZM0 manual motor protector)

 

CI-PKZ0-G(R)(V)

For Motor protector combinations

C123X-125-NA

 

Door coupling handle

 (R)H-PKZ0

(IP 65, UL/NEMA/CSA 12)

 

Mounting depth 125 mm, additional M3-CI23 mounting plate required

IP 65 UL/NEMA/CSA 1, 12, 13, 4x indoor

PKZM0-.../S(E)00

+NHI or NHI...S

+NHI-E

+R(H)

+L-PKZ0 (2 pieces)

 

C123X-150-NA

 

Door coupling handle

 (R)H-PKZ0

(IP 65, UL/NEMA/CSA 12)

 

Mounting depth 150 mm, additional M3-CI23 mounting plate required

IP 65 UL/NEMA/CSA 1, 12, 13, 4x indoor

PKZM0-.../S(E)00

+NHI or NHI...S

+NHI-E

+R(H)

+L-PKZ0 (2 pieces)

 

CLIP PLATES

One of the clip plates is always necessary when combining a PKZM0 manual protector and a S(E)00 magnetic contactor to create a magnetic motor protector combination.

Can be either panel mounted with screws or DIN rail mounted using one 15mm height rail or two 7.5mm height rails.  DIN rails must conform to EN 50 022-35

Type

Article Number

Description

C-PKZ0

Standard Version

C-PKZ0-K

Short Version

 

DOOR COUPLING HANDLES

UL/NEMA 12, IP 65

Type

Article Number

Description

H-PKZ0

 

For use as main switch.  Door/cover interlocked when switch is in the ON position.  Black Color

3 Positions: ON/OFF/+ (tripped).  Lockable in the OFF  position using 3 padlocks (hasp thickness 4-8 mm).  Can also be modified to be lockable in the ON position.

H-PKZ0-MCC

 

For use as main switch in MCC to VDE 0113, with PKZM0 turned 90 degrees

Black Color

 

3 Positions: ON/OFF/+ (tripped).  Lockable in the OFF  position using 3 padlocks (hasp thickness 4-8 mm).  Can also be modified to be lockable in the ON position.

RH-PKZ0

 

For use as main switch with Emergency stop function.  Door/cover interlocking feature.

 

3 Positions: ON/OFF/+ (tripped).  Lockable in the OFF  position using 3 padlocks (hasp thickness 4-8 mm).

RH-PKZ0-MCC

 

For use as main switch in with Emergency stop in MCC to VDE 0113, with PKZM0 turned 90 degrees.

Black Color

3 Positions: ON/OFF/+ (tripped).  Lockable in the OFF  position using 3 padlocks (hasp thickness 4-8 mm).

HSOV-PKZ0

 

Simpler mechanism without any door/cover interlocking or padlocking capability. Color: black, with On/Off and “+” (Tripped) switch position.
A-H-PKZ0 Plug in extension shaft. Supplied with all door coupling handles.  The extension shaft can be cut to any required length to accommodate mounting depths 100-240 mm.

 

ENCLOSURE ACCESSORIES

UL/NEMA 12, IP 65

Type

Article Number

Description

Padlockable Knob Handle

Accommodates 1/4" (3-3.35mm) padlocks.

AK-PZK0

Replaced standard PKZM0 knob handle with a padlockable version.  Padlockable in the OFF position.

Tamper-Sealing Cover

Uses conventional lead seal

PL-PKZ0

To prevent unauthorized access to the motor FLC thermal trip dial setting and the test-to-trip function.

Indicating Lights with Neon Bulbs

L-PKZ0 (230V)

White

110 - 230 V

L-PKZ0 (400V)

White

230 - 400 V

L-PKZ0 (500V)

White

415 - 500 V

L-PKZ0-GN(230V)

Green

110 - 230 V

L-PKZ0-GN(400V)

Green

230 - 400 V

L-PKZ0-RT(230V)

Red

110 - 230 V

L-PKZ0-RT(400V)

Red

230 - 400 V

L-PKZ0-RT(500V)

Red

415 - 500 V

 

BUS CONNECTORS

Three-Phase Feeder Bus Connectors

Finger safe.  Reduces mounting space and wiring time by eliminating daisy-chain wiring; can be joined to accommodate more units.

Type

Article Number

# Motor protectors Length Unit width avail per motor protector
For motor protector and motor protector combinations without side mounted auxiliary contacts or voltage trips.

B3.0/2-PKZ0

2 90 45

B3.0/4-PKZ0

4 180 45
For motor protector and motor protector combinations each with one side mounted auxiliary contact or trip indicating contact module, mounted on the right.

B3.1/2-PKZ0

2 99 45 + 9

B3.1/3-PKZ0

3 153 45 + 9

B3.1/4-PKZ0

4 207 45 + 9

B3.1/5-PKZ0

5 261 45 + 9
For motor protector and motor protector combinations each having one auxiliary contact and trip indicating auxiliary contact module, mounted on the right, or a voltage trip mounted on the left, or for motor protector combinations having a long NHI2-11S-PKZ0 standard auxiliary contact mounted on the right.

B3.2/2-PKZ0

2 108 45 + 18

B3.2/4-PKZ0

4 234 45 + 18
Protective Shroud for Unused Terminals

H-B3-PKZ0

Finger safe covers which slip over unused terminals of a three-phase feeder bus connector to protect against accidental contact
Connector Feeder Terminal

BK25/3-PKZ0

Incoming supply terminal to fee bus connectors, finger-safe design, maximum ampacity: 63 A

Permissible conductor range: AWG 10...4, Cu only

BK25/3-PKZ0-E

Connector with UL 489 distribution spacings on the incoming supply terminals.  To be used in conjunction with PKZM0 motor protectors for UL listing as Type E manual self-protected combination controller.

 

CONTROL PANEL BUS ADAPTER,
3-POLE

The back of the adapter connects onto the bus.  Components are mounted on top of the adapter and wires to the supply leads.  All assembly is done under de-energized (Power Off) conditions

Type

Article Number

Maximum Rated Current Adapter Supply Leads Adapter Width For Use With
PKZ0 Amps AWG mm  

For mounting in industrial control panels on CU 20 x 5 mm busbar arrangements with 60 mm phase separation.

AD25/5-1

25 10 54

PKZM 0-... or

PKZM 0-.../S(E)00

+ AGM or NHI

AD25/5-2

25 10 108

2 x PKZM 0-... or

2 x PKZM 0-.../S(E)00

+AGM or NHI, or

1 x PKZM 0-...

+2 x EZ-PK Z0 + MV-PKZ 0

AD25/5-144

25 10 144

2 x PKZM 0-... or

2 x PKZM 0-.../S(E)00

+AGM or NHI, or

1 x PKZM 0-...

+2 x EZ-PK Z0 + MV-PKZ 0

+AGM or NHI

For mounting in industrial control panels on CU 30 x 10 and 20 x 10 mm busbar arrangements with 60 mm phase separation.

AD25/10-1

25 10 54

PKZM 0-... or

PKZM 0-.../S(E)00

+ AGM or NHI

AD25/10-2

25 10 108

2 x PKZM 0-... or

2 x PKZM 0-.../S(E)00

+AGM or NHI, or

1 x PKZM 0-...

+2 x EZ-PK Z0 + MV-PKZ 0

AD25/10-144

25 10 144

2 x PKZM 0-... or

2 x PKZM 0-.../S(E)00

+AGM or NHI, or

1 x PKZM 0-...

+2 x EZ-PK Z0 + MV-PKZ 0

+AGM or NHI

Adapter Extension

AD-E

--- --- 9 Push fit strip can be fitted onto AD... to extend mounting width

MVS MOUNTING ACCESSORY KITS

Type

Article Number

For Use With Description
MVS Kits for full voltage non-reversing starter combinations.

MVS-D0-EM

PKZM0 + DILE(E)M Includes mounting plate and finger safe wiring harness to accommodate FVNR motor starter combinations consisting of PKZM 0 motor protectors and DIL...M magnetic contactors in various HP sizes.  UL listed/CSA certified for group installations and high fault short circuit current ratings in association with Moeller Electric components.

MVS-D5

PKZM0 + DIL00(A)M

MVS-D11

PKZ0 + DIL0(A)M
Tophat rail adapter for motor protector combinations

MVS-C45

Adapter plate, 45 mm wide, includes connection lug for expansion using MVS-C45 or MVS-C90H, includes connector to expand MVS-D... into a reversing starter.

MVS-C90H

Mounting plate, 90 mm wide, with continuous tophat rail, top and bottom.
Tophat rail adapter for motor protector + contactor combinations

MVS-C45-S

PKZ0 + S(E)00-PKZ0 For use with motor protector combinations in conjunction with other starters on MVS mounting plates.  Parallel feed possible via three-phase bus bars.
Tophat rail extension for tophat rail adapter

MVS-H15

All MVS-C... To allow for wider mounting plate for  reversing starters with mechanical interlock.
Electromechanical link between motor protector and contactor

MVS-LBM0-EM

PKZM0 + DILE(E)M(-G) To electrically and mechanically link the PKZM0 motor protector and DILEM contactor.  For use with and without MVS-C45.
Electrical link between motor protector and contactor

MVS-LB14/140

PKZM0 + DILE(E)M(-G) Flexible link between PKZM0 and DILM contactor

 

MVS-LB14/140: AWG 14, length 140 mm

MVS-LB0-00M-G: AWG 12, length 110 mm

MVS-LB0-0M-G: AWG 10, length 120mm

MVS-LB0-00M-G

PKZM0 + DIL00(A)M(-G)

MVS-LB0-0M-G

PKZM0 + DIL0(A)M(-G)

 

MVS WIRING ACCESSORY KITS

Type

Article Number

For Use With Description
Reversing starter wiring kits

MVS-WB-EM

DILE(E)M (+MVDILEM)

DIULEM

Consisting of a 3-pole paralleling link and a 3-pole reversing link with a bridge for terminal A2 on MVS-WB-EM, includes bridge for electrical interlock.

 

For Complete mounting of reversing starters on a MVS adapter, the following are also required: MVS kit MVS-D... for direct on line starters and MVS-C45 mounting plate.

 

For reversing starters with mechanical interlock (type MVS-...MV), an additional extension with MVS-H15 is required.  Not required for DILEM starters.

MVS-WB5MV

DIL00(A)M + MVDILM

DIUL00(A)M/MV

MVS-WB11MV

DIUL0(A)M + MVDILM

DIUL0(A)M/MV

Star-delta wiring kits

Type

Article Number

For Use With Description
Mains Contactor Delta Contactor Start Contactor

MVS-SB-EM

DILE(E)M DILE(E)M DILE(E)M Consisting of a 3-pole paralleling line, a 3-pole reversing link and a start-point bridge.  On MVS-SB-EM reversing link with additional bridge for terminal A2 and paralleling link with interlocking of star contactor / delta contactor.

For completely mounting star-delta starters on a MVS adapter, the following are also required: MVS kit MVS-D... for direct on line starters and MVS-C90H mounting plate.

MVS-SB-00M

DIL00AM DIL00AM DIL00AM

MVS-SB-0M

DIL0M DIL0M DIL00M

MVS-SB-0AM

DIL0AM DIL0AM DIL0M

MVS-SB-1M

DIL1(A)M DIL1(A)M DIL0(A)M

Let our expert sales staff guide you through finding the right products to fit your needs. CALL 866-595-9616.