Description:

Starter package for getting started with control engineering quickly and easily. The starter package contains the EASY-E4-UC-12RC1 control relay with LCD display and screw terminal connections, a patch cable for connecting the control relay to the Ethernet interface and a license for the easySoft operating and programming software.

EASY-BOX-E4-UC1

Technical Specifications

Main Specifications

DescriptionEASY-BOX-E4-UC1 Starter Package
Product rangeControl relays easyE4
Basic functionStarter kit
Included devices
Y7-197211 EASY-E4-UC-12RC1easyE4 base unit
Y7-197226 EASYSOFT-SWLICSoftware license
Patch cable
Supply voltage12/24 V DC
24 V AC
SoftwareEASYSOFT-SWLIC/easySoft 7
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-E4-AC-12RCX1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
DescriptionEASY-BOX-E4-UC1 Starter Package
Static heat dissipation, non-current-dependent [Pvs]3 W
Operating ambient temperature min.-25 °C
Operating ambient temperature max.+55 °C
DescriptionEASY-BOX-E4-UC1 Starter Package
10.2 Strength of materials and parts
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIESMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
DescriptionEASY-BOX-E4-UC1 Starter Package
PLC's (EG000024) / Logic module (EC001417)
Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / Logic module (ecl@ss10.0.1-27-24-22-16 [AKE539014])
Supply voltage AC 50 Hz20.4 - 28.8 V
Supply voltage AC 60 Hz20.4 - 28.8 V
Supply voltage DC12.2 - 28.8 V
Voltage type of supply voltageAC/DC
Switching current8 A
Number of analogue inputs0
Number of analogue outputs0
Number of digital inputs8
Number of digital outputs4
With relay outputYes
Number of HW-interfaces industrial Ethernet1
Number of interfaces PROFINET0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Number of HW-interfaces Wireless0
Number of HW-interfaces other1
With optical interfaceNo
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for MODBUSYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Radio standard UMTSNo
IO link masterNo
RedundancyNo
With displayYes
Degree of protection (IP)IP20
Basic deviceYes
ExpandableYes
Expansion deviceNo
With timerYes
Rail mounting possibleYes
Wall mounting/direct mountingYes
Front build in possibleYes
Rack-assembly possibleNo
Suitable for safety functionsNo
Category according to EN 954-1None
SIL according to IEC 61508None
Performance level acc. EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Explosion safety category for gasNone
Explosion safety category for dustNone
Width71.5 mm
Height90 mm
Depth58 mm
DescriptionEASY-BOX-E4-UC1 Starter Package
Degree of Protection IEC: IP20, UL/CSA Type: -
DescriptionEASY-BOX-E4-UC1 Starter Package
Product Dimensions

Product Accessories

Starter Pack
EASY-BOX-E4-UC1 Starter Pack

Starter Pack
EASY-BOX-E4-DC1 Starter Pack

Starter Pack
EASY-BOX-E4-AC1 Starter Pack


Software
EASYSOFT-SWLIC Software


10W Power Supply
PSL10E24RP 10W Power Supply

30W Power Supply
PSL30E24RP 30W Power Supply


60W Power Supply
PSL60E24RP 60W Power Supply

100W Power Supply
PSL100E24RP 100W Power Supply


Spare Parts
PSL100E24RP 100W Power Supply

Memory Card
PSL100E24RP 100W Power Supply