Menu

Eaton/Moeller
T5B-4 Switch

  Emergency Use Auxiliary Contacts Poles Max. Motor Rating
400/
415 V
50
/60 Hz
P
kW
Rated
Uninterrupted
Current
Iu
A
Mounting Protection

T5B-4-8344/EA/SVB-SW
T5B-4-8344/EA/SVB-SW

Without Emergency-Stop function --  8 22 63 Flush Front IP65

T5B-4-8344/I4/SVB-SW
T5B-4-8344/I4/SVB-SW

Without Emergency-Stop function --  8 22 63 Surface IP65

T5B-4-8344/EA/SVB
T5B-4-8344/EA/SVB

As Emergency-Stop device --  8 22 63 Flush Front IP65

T5B-4-15682/I4/SVB
T5B-4-15682/I4/SVB

As Emergency-Stop device 1 N/O
1 B
 6 22 63 Surface IP65

T5B-4-15682/I4/SVB-SW
T5B-4-15682/I4/SVB-SW

Without Emergency-Stop function 1 N/O
1 B
 6 22 63 Surface IP65

T5B-4-15682/EA/SVB
T5B-4-15682/EA/SVB

As Emergency-Stop device 1 N/O
1 B
 6 22 63 Flush Front IP65

T5B-4-15682/EA/SVB-SW
T5B-4-15682/EA/SVB-SW
 

Without Emergency-Stop function 1 N/O
1 B
 6 22 63 Flush Front IP65
T5B-4-15682/V/SVB
T5B-4-15682/V/SVB
 
As Emergency-Stop device 1 N/O
1 B
 6 22 63 Rear Front IP65

T5B-4-15682/V/SVB-SW
T5B-4-15682/V/SVB-SW

Without Emergency-Stop function 1 N/O
1 B
 6 22 63 Rear Front IP65

T5B-4-8344/I4/SVB
T5B-4-8344/I4/SVB

As Emergency-Stop device --  8 22 63 Surface IP65

T5B-4-8344/V/SVB
T5B-4-8344/V/SVB

As Emergency-Stop device --  8 22 63 Rear Front IP65

On Off Switches

  Mounting Auxiliary Contacts Poles Max. Motor Rating
AC-23A
400/415V
50/60 HZ
P
kW
Rated
Uninterrupted Current

T5B-4-15682/E

Flush 1 NO, 1 B 6 22 63

T5B-4-15682/Z
T5B-4-15682/Z

Rear 1 NO, 1 B 6 22 63

T5B-4-15682/I4
T5B-4-15682/I4

Surface 1 NO, 1 B 6 22 63

T5B-4-8344/I4
T5B-4-8344/I4

Surface -- 8 22 63

Changeover Switches

  Mounting Description Notes Poles Max. Motor Rating
AC-23A
400/415V
50/60 HZ
P
kW
Rated
Uninterrupted Current
T5B-4-8223/Z
T5B-4-8223/Z
Rear Without 0 (Off) position Changeover switches 4 22 63
T5B-4-8223/E
T5B-4-8223/E
Flush Without 0 (Off) position Changeover switches 4 22 63
T5B-4-8223/I4
T5B-4-8223/I4
Surface Without 0 (Off) position Changeover switches 4 22 63
T5B-4-8294/Z
T5B-4-8294/Z
Rear With 0 (Off) position Group switches
Mains Transfer Switch
4 22 63
T5B-4-8294/E
T5B-4-8294/E
Flush With 0 (Off) position Group switches
Mains Transfer Switch
4 22 63
T5B-4-8213/Z
T5B-4-8213/Z
Rear With 0 (Off) position Group switches
Mains Transfer Switch
4 22 63
T5B-4-8213/E
T5B-4-8213/E
Flush With 0 (Off) position Group switches
Mains Transfer Switch
4 22 63
T5B-4-8213/I4
T5B-4-8213/I4
Surface With 0 (Off) position Group switch
Mains Transfer Switch
4 22 63
T5B-4-8294/I4
T5B-4-8294/I4
Surface With 0 (Off) position Group switch
Mains Transfer Switch
 4 22 63
T5B-4-8902/I4
T5B-4-8902/I4
Surface With 0 (Off) position Group switch
Mains Transfer Switch
4 22 63
T5B-4-8902/E
T5B-4-8902/E
Flush With 0 (Off) position Group switch
Mains Transfer Switch
 4 22 63
T5B-4-8902/Z
Rear With 0 (Off) position Group switch
Mains Transfer Switch
4 22 63

T5B-4 AWA

T5(B).../E(+SVB), T5(B).../EA/SVB
T5(B).../Z(+SVB), T5(B).../V/SVB
T5B.../I4, T5B.../I4/SVB, T5.../I5
T5.../I5/SVB
05/05 AWA1150-1692
332 KB

T5B-4 Overview



 
Service distribution board mounting
(.../IVS) 1

Front IP30
For snap fitting to
EN 50022 top-hat rail
Flush
– Service distribution boards: up to
3 contact units (45 mm mounting depth)
– Control panels: up to 11 contact units
Rear mounting (.../Z) 2
Front IP65
Secured by screw fixing or snap fitting
(T0 or T3)
For snap fitting to
EN 50022 top-hat rail
Coupling drive in door or cover
Connection from the front

Rear mounting main switches
(.../V/SVB)
2
Front IP65
According to IEC/EN 60204 and
IEC/EN 60947-3,
for T0... up to 8 and for T3...
up to 12 current paths
With door interlock in the On position
Flush (.../E) 3
Front IP65
Fitting and connection from the rear
Terminal:
Pozidriv plus-minus screw
Finger- and back-of-hand proof
Type T8 with extension terminals as
standard
Flush main switches

(.../EA/SVB) 3
Front IP65
According to IEC/EN 60204 and
IEC/EN 60947-3,
for T0... up to 8 and for T3...
up to 12 current paths
N terminal and PE terminal

Centre mounting (.../EZ) 3
Front IP65
Mounting in ∅ 22.3 fixing hole
according to IEC/EN 60947-5-1
“One-man installation” through centre
fixing
Surface mounting (.../I...) 4
IP65
With an additional terminal
Enclosures for metric cable glands
according to EN 50262
Surface mounting main switches

(.../I...) 4
IP65
According to IEC/EN 60204 and
IEC/EN 60947-3,
for T0... up to 8 and for T3...
up to 10 current paths
Lockable in 0 position with 3 padlocks
Enclosures for metric cable glands
according to EN 50262
With an additional terminal
Safety switch (.../I...) 5
IP65
With an additional terminal
With cover fuse in the 0 position
Lockable in 0 position with 3 padlocks
Enclosures for metric cable glands
according to EN 50262
With “Safety Switch” label
Colour: orange
in Switzerland: according to SUVA
Directive
Main switch (assembly kit)
for use as Emergency-Stop device
6

According to IEC/EN 60204-1
With red rotary handle and yellow locking
collar
Lockable in 0 position
Main switch (assembly kit) 7
Black rotary handle and locking collar
Lockable in the 0 (Off) position
Thumb-grip
for use as Emergency-Stop device
8

According to IEC/EN 60204-1
Red thumb-grip with yellow front plate
Thumb-grip 9
Black thumb-grip with front plate
Coupling drive 10
Includes push-fit shaft
For retrofitting T0(T3)-.../XZ basic
switches for rear mounting
Spare parts for T0(T3)/(P1)-.../Z
For retrofit conversion of T5(B)-.../E
Flush switches for rear mounting
Spare part for T5(B)-.../Z

View Rotary Switch Catalog Documentation

 

Let our expert sales staff guide you through finding the right products to fit your needs. CALL 866-595-9616.