Eaton/Moeller
T5B-3 Switch |
|
Emergency Use |
Auxiliary
Contacts |
Poles |
Max. Motor Rating
400/
415 V
50
/60 Hz
P
kW |
Rated
Uninterrupted
Current
Iu
A |
Mounting |
Protection |
T5B-3-8342/EA/SVB-SW
|
Without Emergency-Stop function |
-- |
6 |
22 |
63 |
Flush |
Front IP65 |
T5B-3-8342/I4/SVB-SW
|
Without Emergency-Stop function |
-- |
6 |
22 |
63 |
Surface |
IP65 |
T5B-3-8342/V/SVB-SW
|
Without Emergency-Stop function |
-- |
6 |
22 |
63 |
Rear |
Front IP65 |
T5B-3-8342/EA/SVB
|
As Emergency-Stop device |
-- |
6 |
22 |
63 |
Flush |
Front IP65 |
T5B-3-8901/I4/SVB
|
As Emergency-Stop device |
1 NO
1 B |
3 + N |
22 |
63 |
Surface |
IP65 |
T5B-3-8901/I4/SVB-SW
|
Without Emergency-Stop function |
1 NO
1 B |
3 + N |
22 |
63 |
Surface |
IP65 |
T5B-3-8901/EA/SVB-
SW
|
Without Emergency-Stop function |
1 NO
1 B |
3 + N |
22 |
63 |
Flush |
Front IP65 |
T5B-3-8342/I4/SVB
|
As Emergency-Stop device |
-- |
6 |
22 |
63 |
Surface |
IP65 |
T5B-3-8342/V/SVB
|
As Emergency-Stop device |
-- |
6 |
22 |
63 |
Rear |
Front IP65 |
On Off Switches |
|
Mounting |
Auxiliary Contacts |
Poles |
Max. Motor Rating
AC-23A
400/415V
50/60 HZ
P
kW |
Rated
Uninterrupted Current |
T5B-3-8342/E
|
Flush |
-- |
6 |
22 |
63 |
T5B-3-8342/I4
|
Surface |
-- |
6 |
22 |
63 |
|
Article |
Name |
Description |
092386 |
T5B-3-8212/E |
ROTARY CAM SWITCH |
092378 |
T5B-3-8222/E |
ROTARY CAM SWITCH |
092310 |
T5B-3-8342/E |
ROTARY CAM SWITCH |
109993 |
T5B-3-8228/E-NA |
ROTARY CAM SWITCH |
109992 |
T5B-3-8401/E-NA |
ROTARY CAM SWITCH |
110014 |
T5B-3-8451/E-NA |
ROTARY CAM SWITCH |
|
092308 |
T5B-3-8342/EA/SVB |
ROTARY CAM SWITCH |
|
092307 |
T5B-3-8342/EA/SVB-SW |
ROTARY CAM SWITCH |
|
109986 |
T5B-3-8212/I4-NA |
ROTARY CAM SWITCH |
109991 |
T5B-3-8222/I4-NA |
ROTARY CAM SWITCH |
110001 |
T5B-3-8228/I4-NA |
ROTARY CAM SWITCH |
110020 |
T5B-3-8451/I4-NA |
ROTARY CAM SWITCH |
109998 |
T5B-3-8401/I4-NA |
ROTARY CAM SWITCH |
109971 |
T5B-3-8342/I4-NA |
ROTARY CAM SWITCH |
109943 |
T5B-3-8342/I4/SVB-NA |
ROTARY CAM SWITCH |
109951 |
T5B-3-8342/I4/SVB-SW-NA |
ROTARY CAM SWITCH |
|
092300 |
T5B-3-8342/V/SVB |
ROTARY CAM SWITCH |
|
092299 |
T5B-3-8342/V/SVB-SW |
ROTARY CAM SWITCH |
|
092383 |
T5B-3-8212/Z |
ROTARY CAM SWITCH |
092375 |
T5B-3-8222/Z |
ROTARY CAM SWITCH |
092297 |
T5B-3-8342/Z |
ROTARY CAM SWITCH |
110011 |
T5B-3-8401/Z-NA |
ROTARY CAM SWITCH |
110031 |
T5B-3-8451/Z-NA |
ROTARY CAM SWITCH |
110012 |
T5B-3-8228/Z-NA |
ROTARY CAM SWITCH |
|
T5B-3 AWA |
|
T5(B).../E(+SVB), T5(B).../EA/SVB
T5(B).../Z(+SVB), T5(B).../V/SVB
T5B.../I4, T5B.../I4/SVB, T5.../I5
T5.../I5/SVB
05/05 AWA1150-1692
332 KB |
|
T5B-3 Overview |
Service
distribution board mounting
(.../IVS) 1
Front IP30
For snap fitting to
EN 50022 top-hat rail
Flush mounting
– Service distribution boards: up to
3 contact units (45 mm mounting depth)
– Control panels: up to 11 contact units |
Rear mounting
(.../Z) 2
Front IP65
Secured by screw fixing or snap fitting
(T0 or T3)
For snap fitting to
EN 50022 top-hat rail
Coupling drive in door or cover
Connection from the front
Rear mounting main switches
(.../V/SVB)
2
Front IP65
According to IEC/EN 60204 and
IEC/EN 60947-3,
for T0... up to 8 and for T3...
up to 12 current paths
With door interlock in the On position |
Flush mounting
(.../E) 3
Front IP65
Fitting and connection from the rear
Terminal:
Pozidriv plus-minus screw
Finger- and back-of-hand proof
Type T8 with extension terminals as
standard
Flush mounting main switches
(.../EA/SVB) 3
Front IP65
According to IEC/EN 60204 and
IEC/EN 60947-3,
for T0... up to 8 and for T3...
up to 12 current paths
N terminal and PE terminal
Centre mounting (.../EZ) 3
Front IP65
Mounting in ∅ 22.3 fixing hole
according to IEC/EN 60947-5-1
“One-man installation” through centre
fixing |
Surface mounting
(.../I...) 4
IP65
With an additional terminal
Enclosures for metric cable glands
according to EN 50262
Surface mounting main switches
(.../I...) 4
IP65
According to IEC/EN 60204 and
IEC/EN 60947-3,
for T0... up to 8 and for T3...
up to 10 current paths
Lockable in 0 position with 3 padlocks
Enclosures for metric cable glands
according to EN 50262
With an additional terminal |
Safety switch
(.../I...) 5
IP65
With an additional terminal
With cover fuse in the 0 position
Lockable in 0 position with 3 padlocks
Enclosures for metric cable glands
according to EN 50262
With “Safety Switch” label
Colour: orange
in Switzerland: according to SUVA
Directive |
Main switch
(assembly kit)
for use as Emergency-Stop device
6
According to IEC/EN 60204-1
With red rotary handle and yellow locking
collar
Lockable in 0 position |
Main switch
(assembly kit) 7
Black rotary handle and locking collar
Lockable in the 0 (Off) position |
Thumb-grip
for use as Emergency-Stop device
8
According to IEC/EN 60204-1
Red thumb-grip with yellow front plate |
Thumb-grip 9
Black thumb-grip with front plate |
Coupling drive 10
Includes push-fit shaft
For retrofitting T0(T3)-.../XZ basic
switches for rear mounting
Spare parts for T0(T3)/(P1)-.../Z
For retrofit conversion of T5(B)-.../E
flush mounting switches for rear mounting
Spare part for T5(B)-.../Z |
|
|
View Rotary Switch Catalog
Documentation