Part Name
Image |
Description |
Supply
voltage |
Response
sensitivity |
|
EMR4-N100-1-B |
- Monitors the level of conductive liquids
- Monitors the ratio of mixtures of conductive
liquids
- Selectable: protection against running dry
or overflowing
|
220 – 240
V AC |
5 Ώ –
100 kΏ |
|
EMR4-N500-2-B |
- Monitors the level of conductive liquids
- Monitors the ratio of mixtures of conductive
liquids
- Selectable On-delay or Off-delay between 0.5 –
10 s
|
250 Ώ –
500
kΏ |
EMR4-N500-2-A |
- Monitors the level of conductive liquids
- Monitors the ratio of mixtures of
conductive
liquids
- Selectable On-delay or Off-delay between
0.5
– 10 s
|
24 – 240 V
AC/DC |
EMR4-R... insulation monitoring relays |
Part Name
Image |
Description |
Supply
voltage |
Insulation
resistance
range
Ώ |
|
EMR4-RDC-1-A |
- Monitors the insulation resistance in nonearthed
DC supply systems
- Selector switch for open- or closed-circuit
principle
- With test and reset facilities
- Status indication via LEDs
|
24 – 240 V
AC/DC |
10 – 110 kΏ |
EMR4-RAC-1-A |
- Monitors the insulation resistance between
non-earthed AC supply systems and the protective
conductor/earth
- Tripping function memory
- Insulation monitoring in 1- and 3-phase AC
supply systems
- Test via local test button or remote test
operation
- Status indication via LEDs to VDE 0413 / Part 2
|
EMR4-I... current monitor relays |
Part Name
Image |
Description |
Supply
voltage |
Current
measuring
range |
|
EMR4-I1-2-A |
- Switching hysteresis adjustable from 5 – 30 %
- Response delay 0.1 – 30 s
- EMR4...-A: monitors one upper or lower limit
- EMR4...-B: monitors one upper limit
- Extension of the measurement range possible with
current transformers
|
24 – 240
V
AC/DC |
3 – 30 mA
10 – 100 mA
0.1 – 1 A |
EMR4-I15-2-A |
0.3 – 1.5 A
1 – 5 A
3 –
15 A |
EMR4-I15-2-B |
220 – 240
V AC |
0.3 – 1.5 A
1 – 5 A
3 –
15 A |
EMR4-F... phase sequence relay |
Part Name
Image |
Description |
Supply
voltage |
Monitoring
voltage |
|
EMR4-F500-2 |
- Monitors three-phase systems for phase sequence
and phase failure
- Supply voltage = voltage being monitored
|
200 – 500
V AC |
EMR4-A... phase imbalance monitoring
relay |
Part Name
Image |
Description |
Supply
voltage |
Monitoring
voltage |
|
EMR4-A400-1 |
- Monitors three-phase systems for phase imbalance
- Detects phase failure even at 95% voltage feedback
from the motor
- Response delay: 0.5 s
- Phase imbalance response threshold adjustable from 5
– 15 %
- Phase sequence detection
- Supply voltage = voltage being monitored
|
380 – 415 V
50 Hz |
EMR4-W phase monitoring relay |
Part Name
Image |
Description |
Supply
voltage |
Monitoring
voltage
adjustable
from |
|
EMR4-W500-2-C |
- Monitors three-phase systems for phase sequence,
over- and undervoltage and phase failure (< 0.6 x Ue)
- 3-phase voltage monitoring within a range
- Selectable On-delay or Off-delay (0.1 – 10 s)
|
160 – 330
V AC |
Umin 300 –
380
V AC
Umax 420 –
500 V AC |
EMR4-W500-2-D |
300 – 500
V AC |
EMR4-W580-2-D |
300 – 500
V AC |
Umin 350 –
430 V AC
Umax 500 –
580 V AC |
|