Moeller FAZ-NA 1077 Supplementary Protectors
Accessories Index

Standard Auxiliary Contacts

Standard
Auxiliary
Contacts
Description Rated
Operational
Voltage
Part
Number
FAZ-XHIN11 Auxiliary Contacts
  • - 1NO/1NC
  • - Installs on left side of FAZ or shunt trip
  • - Max. one per FAZ (1077) device
  • - Switches when FAZ is tripped
  • - Electrically or manually
230 Vac FAZ-XHIN11
  • - 1 changeover contact
  • - Installs on left side of FAZ or shunt trip
  • - Max. one per FAZ (1077) device
  • - Switches when FAZ is tripped electrically or manually
230 Vac FAZ-XHINW1

Auxiliary/Trip Indicating Contact

Auxiliary/Trip
Indicating Contact
Description Rated
Operational
Voltage
Part
Number
/FAZ-XAM002 Auxiliary/Trip Indicating Contact
  • - Small selector screw changes mode
  • - Two Form C (changeover) contacts
  • - Installs on left side of FAZ or shunt trip
  • - Auxiliary contacts switch when FAZ is tripped electrically or manually
  • - Trip indicating contact switches only when FAZ is tripped electrically
230 Vac FAZ-XAM002

Undervoltage Trip

Undervoltage Trip Description Rated
Operational
Voltage
Part
Number
FAZ-XUA Undervoltage Trip
  • - Prevents FAZ from operating unless voltage is present
  • - Installs on left side of FAZ
  • - Includes test button
115 Vac FAZ-XUA(115VAC)
230 Vac FAZ-XUA(230VAC)
400 Vac FAZ-XUA(400VAC)

Shunt Trip

Shunt Trip Description Rated
Operational
Voltage
Part
Number
FAZ-XAA-C-12 Shunt Trip
  • - Allows remote trip of FAZ
  • - Installs on left side of FAZ
12–110 Vac
12–60 Vdc
FAZ-XAA-C-12-110VAC
110–415 Vac
110–230 Vdc
FAZ-XAA-C-110-415VAC

Allowable Combinations of Accessories


FAZ-XAA-C-12 Shunt Trip

FAZ-NA 1077 Supplementary Protectors
Busbar System

Without
Auxiliary Contacts
Rated Operational Current Number of Poles
per Device
Number of
Terminals
Part Number (1)

For connecting FAZ supplementary protectors without auxiliary contacts. May be fed from line or load side.


BussBar Without Auxiliary Contacts

80A 1 57 BB-UL-18/1P-1M/57
2 56 BB-UL-18/2P-2M/56
3 57 BB-UL-18/3P-3M/57
100A 1 57 BB-UL-25/1P-1M/57
2 56 BB-UL-25/2P-2M/56
3 57 BB-UL-25/3P-3M/57
Auxiliary/Trip
Indicating Contacts
Rated Operational Current Number of Poles
per Device
Number of
Terminals
Part Number (1)

For connecting FAZ supplementary protectors with auxiliary contacts. May be fed from line or load side.


BussBar Aux Trip Indicating Contact

80A 1 37 BB-UL-18/1P-1,5M/37
2 46 BB-UL-18/2P+AS-2,5M/46
3 48 BB-UL-18/3P+AS-3,5M/48
100A 1 37 BB-UL-25/1P-1,5M/37
2 46 BB-UL-25/2P+AS-2,5M/46
3 48 BB-UL-25/3P+AS-3,5M/48

NOTE: (1) Bus may be center fed for high current capacity.


BussBar Assembly Dwg

FAZ-NA 1077 Supplementary Protectors
Accessories

Pin Type Incoming Supply Terminals

Incoming Terminal Description Part Number
Pin Type Incoming Supply Terminals
  • - Accommodates conductors from 6–35 mm2/#10–2 AWG
  • - 4–5.5 Nm/35–50 lb-in
  • - Two- and three-pole
BB-UL-TEP/35

Pin Type Incoming Supply Terminals
Single-Phase Only

Incoming Terminal Description Part Number
Pin Type Incoming Supply Terminals Single-Phase Only
  • - Accommodates conductors from 6–35 mm2/#10–2 AWG
  • - 4–5.5 Nm/35–50 lb-in
BB-UL-TEPA/35

Protective Accessories

Busbar Terminal Cover Description Part Number
FAZ Protective Accessories For covering
unused terminals
BB-IP/5
Lockoff Device Description Part Number
FAZ UL lockoff device UL lockoff device FAZPLOFF
Padlock Hasp Description Part Number
FAZ Padlock Hasp
  • - Prevents reactivation of the device during maintenance
  • - Holds one padlock
Z-IS/SPE-1TE

Bus Incoming Supply Terminals

Incoming Terminal Description Part Number
FAZ Bus Incoming Supply Terminals
  • - 50 mm2
  • - #14–1 AWG
  • - 75 Deg wire
  • - 115 A/Y, 480V UL
  • - 160 A/Y 690V IEC
BB-UL-TE/50

Busbar End Cap

Fork Connector Description Poles Part Number
FAZ Busbar End Cap Fork Connector
  • - Install after cutting busbar
  • - Protects end of busbar
2 and 3 BB-EV-EC/3
1 BB-UL-EC/1