Description:
Electronic control relay easy-E4 with supply voltage 24 VDC. 8 digital inputs with 24VDC are available, of which 4 inputs can also be used as analog inputs and 4 inputs as fast counter. The control relay easy-E4 has 4 transitor outputs for 24 VDC. The control relay is equipped with diagnostic LEDs, a clock, an integrated Ethernet interface and screw terminals. This control relay easy-E4 can be extended with the digital input/output extensions of the easyE4 series.
EASY-E4-DC-12TCX1
Technical Specifications
Main Specifications
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Basic function | easyE4 base device |
Description | Electronic control relay Rated operating voltage 24V DC 8 digital inputs for 24 VDC of these, 4 inputs can also be used as analog inputs and 4 inputs as fast counters 4 transistor outputs for 24 VDC with diagnostic LEDs Real-time clock with Ethernet interface Expandable with the easyE4 series of digital input/output expansions with easy-E4-CONNECT1 connector (Item Y7-197225) Screw terminals |
Digital | 8 |
of which can be used as analog | 4 |
Quantity of outputs | Transistor: 4 |
Real time clock | ✔ |
Expansions | Expandable networkable (Ethernet) |
Supply voltage | 24 V DC |
Software | EASYSOFT-SWLIC/easySoft 7 |
Connection type | screw terminal |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Screw terminals Solid | 0.2 - 4 mm2 |
Screw terminals flexible | 0.2 - 2.5 mm2 |
Screw terminals Solid or flexible conductor, with ferrule | 0,2 - 2,5 mm2 |
Screw terminals Solid or stranded | 22 - 12 AWG |
Screw terminals Standard screwdriver | 0.8 x 3.5 mm |
Screw terminals Tightening torque | 0.5 - 0.7 Nm |
Screw terminals Stripping length | 6.5 mm |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Status indicator (LED) | Power/RUN Ethernet |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Operating ambient temperature | -25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C |
Condensation | Take appropriate measures to prevent condensation |
Storage [ϑ] | -40 - +70 °C |
relative humidity | in accordance with IEC 60068-2-30, IEC 60068-2-78 5 - 95 % |
Air pressure (operation) | 795 - 1080 hPa |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Protection type (IEC/EN 60529, EN50178, VBG 4) | IP20 |
Vibrations | In accordance with IEC 60068-2-6 constant amplitude 0.15 mm: 10 - 57 constant acceleration 2 g: 57 - 150 Hz |
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms | 18 Impacts |
Drop to IEC/EN 60068-2-31 [Drop height] | 50 mm |
Free fall, packaged (IEC/EN 60068-2-32) | 0.3 m |
Mounting position | Vertical or horizontal |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Overvoltage category/pollution degree | III/2 |
Electrostatic discharge (ESD) applied standard | nach IEC/EN 61000-4-2 |
Electrostatic discharge (ESD) Air discharge | 8 kV |
Electrostatic discharge (ESD) Contact discharge | 6 kV |
Electromagnetic fields (RFI) to IEC EN 61000-4-3 | 0.08 - 1.0 GHz: 10 1.4 - 2 GHz: 3 2.0 - 2.7 GHz: 1 V/m |
Radio interference suppression | EN 61000-6-3 Class B |
Burst | according to IEC/EN 61000-4-4 Supply cables: 2 Signal cables: 2 kV |
power pulses (Surge) | according to IEC/EN 61000-4-5 0.5 kV (supply cables, symmetrical) 1 kV (supply cables, asymmetrical) |
Immunity to line-conducted interference to (IEC/EN 61000-4-6) | 10 V |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Clearance in air and creepage distances | nach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
Insulation resistance | per EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Accuracy of timing relays (of values) | ± 0.02 % |
Resolution Range “S” | 5 ms |
Resolution Range “M:S” | 1 s |
Resolution Range “H:M” | 1 min |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Rated operational voltage [Ue] | 24 DC (-15/+20%) V |
Permissible range [Ue] | 20.4 - 28.8 V DC |
Residual ripple | ≦ 5 % |
Protection against polarity reversal | yes |
Input current | max. 80 mA at Ue |
Voltage dips | ≤ 10 ms |
Fuse | ≧ 1A (T) A |
Power loss [P] | Normally 2 W |
Heat dissipation at 24 V DC | 2 W |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Number | 8 |
Inputs can be used as analog inputs | 4 (I5, I6, I7, I8) |
Potential isolation | from power supply: no to the memory card: no to Ethernet: yes between inputs: no from the outputs: yes to expansion devices: yes |
Rated operational voltage [Ue] | 24 V DC |
Input voltage | Signal 0: ≦ 5 (I1 - I8) Condition 1: ≧ 15 (I1 - I8) V DC |
Input current at signal 1 | 3.3 (I1 – I4) 1.8 (I5 – I8) mA |
Deceleration time | 20 (0 -> 1/1 -> 0, Debounce ON) type 0.015 (0 -> 1/1 -> 0, Debounce OFF) ms |
Cable length | 100 (unshielded) m |
Frequency counter Number | 4 (I1, I2, I3, I4) |
Frequency counter Counter frequency | ≦ 5 kHz |
Frequency counter Pulse shape | Square |
Frequency counter Pulse pause ratio | 1:1 |
Frequency counter Cable length | ≦ 20 (screened) m |
Incremental counter Number of counter inputs | 2 (I1 + I2, I3 + I4) |
Incremental counter Value range | -2147483648 to +2147483647 |
Incremental counter Counter frequency | ≦ 5 kHz |
Incremental counter Pulse shape | Square |
Incremental counter Signal offset | 90° |
Incremental counter Pulse pause ratio | 1:1 |
Incremental counter Cable length | ≦ 20 (screened) m |
Rapid counter inputs Number | 4 (I1, I2, I3, I4) |
Rapid counter inputs Value range | -2147483648 to +2147483647 |
Rapid counter inputs Counter frequency | ≦ 10 kHz |
Rapid counter inputs Pulse shape | Square |
Rapid counter inputs Pulse pause ratio | 1:1 |
Rapid counter inputs Cable length | ≦ 20 (screened) m |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Number | 4 (I5, I6, I7, I8) |
Potential isolation | from power supply: no to the memory card: no to Ethernet: yes between inputs: no from the outputs: yes to expansion devices: yes |
Input type | DC voltage |
Signal range | 0-10 V DC |
Resolution | 12 Bit (value 0 - 4095) |
Input impedance | 13.3 kΩ |
Accuracy of actual value two devices from series | ± 3 , ± 0.12 V % |
Accuracy of actual value Within a single device | ± 2, ± 0.12 V % |
Conversion time, analog/digital | each CPU cycle ms |
Input current | < 1 mA |
Cable length | ≦ 30, screened m |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Number | 4 |
Rated operational voltage [Ue] | 24 V DC |
Permissible range [Ue] | 20.4 - 28.8 V DC |
Residual ripple | 5 % |
Supply current | Norm./max. 15 mA |
Protection against polarity reversal | Yes (Caution: A short circuit will occur if a supply voltage of the wrong polarity is applied to the outputs.) |
Potential isolation | from power supply: yes to the memory card: yes to Ethernet: yes From the inputs: yes to control buttons: yes between the outputs: no to expansion devices: yes |
Rated operational current at signal „1” DC per channel [Ie] | Max. 0.5 A |
Residual current on 0 signal per channel | < 0.005 mA |
Max. output voltage | 1 (at status 0 per channel) U = Ue - 1 V (signal 1 at Ie = 0.5 A) V |
Short-circuit protection | yes, electronic (Q1 - Q4) |
Short-circuit tripping current for Ra ≦ 10 mΩ | 0.7 ≦ Ie ≦ 1.7 per output depending on number of active channels and their load A |
Total short-circuit current | 6.8 A |
Thermal cutout | Yes |
Max. operating frequency with constant resistive load | abhängig von der Zykluszeit des Basisgeräts und bei Erweiterungsgeräten auch von deren Übertragungszeit Operations/h |
Parallel connection of outputs With resistive load, inductive load with external suppressor circuit, combination within a group | Group 1: Q1 to Q4 |
Parallel connection of outputs Number of outputs [max.] | 4 |
Parallel connection of outputs Max. total current | 2 A |
Inductive load to EN 60947-5-1 Without external suppressor circuit DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H Utilization factor | 0.25 g |
Inductive load to EN 60947-5-1 Without external suppressor circuit DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H Duty factor | 100 % DF |
Inductive load to EN 60947-5-1 Without external suppressor circuit T0.95 = 15 ms, R = 48 Ω, L = 0.24 H Utilization factor | 0.25 g |
Inductive load to EN 60947-5-1 Without external suppressor circuit T0.95 = 15 ms, R = 48 Ω, L = 0.24 H Duty factor | 100 % DF |
Inductive load to EN 60947-5-1 With external suppressor circuit Utilization factor | 1 g |
Inductive load to EN 60947-5-1 With external suppressor circuit Duty factor | 100 % DF |
Inductive load to EN 60947-5-1 With external suppressor circuit Max. switching frequency, max. duty factor | Depending on the suppressor circuit Operations |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Data transfer rate | 10/100 Mbit/s |
Connections | RJ45 plug, 8-pin |
Cable | CAT5 |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
Static heat dissipation, non-current-dependent [Pvs] | 2 W |
Operating ambient temperature min. | -25 °C |
Operating ambient temperature max. | +55 °C |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
10.2 Strength of materials and parts 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
10.2 Strength of materials and parts 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
10.2 Strength of materials and parts 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
10.2 Strength of materials and parts 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. |
10.2 Strength of materials and parts 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
10.2 Strength of materials and parts 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts 10.2.7 Inscriptions | Meets the product standard's requirements. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard's requirements. |
10.4 Clearances and creepage distances | Meets the product standard's requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
10.8 Connections for external conductors | Is the panel builder's responsibility. |
10.9 Insulation properties 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
10.9 Insulation properties 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
10.9 Insulation properties 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder's responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
PLC's (EG000024) / Logic module (EC001417) | |
Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / Logic module (ecl@ss10.0.1-27-24-22-16 [AKE539014]) | |
Supply voltage AC 50 Hz | 0 - 0 V |
Supply voltage AC 60 Hz | 0 - 0 V |
Supply voltage DC | 20.4 - 28.8 V |
Voltage type of supply voltage | DC |
Switching current | 0.5 A |
Number of analogue inputs | 4 |
Number of analogue outputs | 0 |
Number of digital inputs | 8 |
Number of digital outputs | 4 |
With relay output | No |
Number of HW-interfaces industrial Ethernet | 1 |
Number of interfaces PROFINET | 0 |
Number of HW-interfaces RS-232 | 0 |
Number of HW-interfaces RS-422 | 0 |
Number of HW-interfaces RS-485 | 0 |
Number of HW-interfaces serial TTY | 0 |
Number of HW-interfaces USB | 0 |
Number of HW-interfaces parallel | 0 |
Number of HW-interfaces Wireless | 0 |
Number of HW-interfaces other | 1 |
With optical interface | No |
Supporting protocol for TCP/IP | Yes |
Supporting protocol for PROFIBUS | No |
Supporting protocol for CAN | No |
Supporting protocol for INTERBUS | No |
Supporting protocol for ASI | No |
Supporting protocol for KNX | No |
Supporting protocol for MODBUS | Yes |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for SUCONET | No |
Supporting protocol for LON | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for SERCOS | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for other bus systems | No |
Radio standard Bluetooth | No |
Radio standard WLAN 802.11 | No |
Radio standard GPRS | No |
Radio standard GSM | No |
Radio standard UMTS | No |
IO link master | No |
Redundancy | No |
With display | No |
Degree of protection (IP) | IP20 |
Basic device | Yes |
Expandable | Yes |
Expansion device | No |
With timer | Yes |
Rail mounting possible | Yes |
Wall mounting/direct mounting | Yes |
Front build in possible | Yes |
Rack-assembly possible | No |
Suitable for safety functions | No |
Category according to EN 954-1 | None |
SIL according to IEC 61508 | None |
Performance level acc. EN ISO 13849-1 | None |
Appendant operation agent (Ex ia) | No |
Appendant operation agent (Ex ib) | No |
Explosion safety category for gas | None |
Explosion safety category for dust | None |
Width | 71.5 mm |
Height | 90 mm |
Depth | 58 mm |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|
UL File No. | E205091 |
UL Category Control No. | NRAQ/7 |
North America Certification | UL listed |
Degree of Protection | IEC: IP20, UL/CSA Type: - |
Description | EASY-E4-DC-12TCX1 Base Unit |
---|---|