KMParts.com is "THE" source for industrial automation control components

Eaton

EASY-E4-AC-16RE1

Expansion Unit

Eaton

EASY-E4-AC-16RE1

Expansion Unit

Eaton

EASY-E4-AC-16RE1

Expansion Unit

Eaton EASY-E4-AC-16RE1 Expansion Unit

Description:

I/O expansion, Supply voltage: 100 - 240 V AC, 110 - 220 V DC. In cULus applications applies 100-110 VDC to all V DC Information. Can be used via easyConnect, Mounting position: Vertical or horizontal, Protection type (IEC/EN 60529, EN50178, VBG 4): IP20, Standards: EN 61000-6-2, EN 61000-6-3, IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-30, IEC 60664, IEC 61131-2, EN 61010, EN 50178, cULus per UL 61010, CSA C22.2 No.61010

EASY-E4-AC-16RE1

Technical Specifications

Main Specifications

DescriptionEASY-E4-AC-16RE1 Expansion Unit
Product rangeControl relays easyE4
SubrangeeasyE4 digital input/output enhancements
Basic functioneasyE4 extensions
DescriptionInput/output extension for easyE4 control relay
Expandable with the easyE4 series of digital input/output expansions with easy-E4-CONNECT1 connector (Item Y7-197225)
Rated operating voltage 100 to 240V AC or 100 to 240V DC
Digital inputs: 8
Digital outputs: 8 relays
Screw terminals
Inputs expansion (number)digital: 8
Displaywith diagnostic LED
SoftwareEASYSOFT-SWLIC/easySoft 7
Supply voltage100 - 240 V AC, 100 - 240 V DC (cULus: 100 - 110 V DC)
For use witheasyE4
DescriptionEASY-E4-AC-16RE1 Expansion Unit
StandardsEN 61000-6-2
EN 61000-6-3
IEC 60068-2-6
IEC 60068-2-27
IEC 60068-2-30
IEC/EN 61131-2
EN 61010
EN 50178
Approvals
Approvals
cULus
Approvals
certificate
CE
Approvals
shipping classification
DNV GL
ApprovalsDVN GL Approval
Dimensions (W x H x D)71.5 x 90 x 58 mm
Weight0.232 kg
MountingTop-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Connection typescrew terminal
DescriptionEASY-E4-AC-16RE1 Expansion Unit
Screw terminals
Solid
0.2 - 4 mm2
Screw terminals
flexible
0.2 - 2.5 mm2
Screw terminals
Solid or flexible conductor, with ferrule
0,2 - 2,5 mm2
Screw terminals
Solid or stranded
22 - 12 AWG
Screw terminals
Standard screwdriver
0.8 x 3.5 mm
Screw terminals
Tightening torque
0.5 - 0.7 Nm
Screw terminals
Stripping length
6.5 mm
DescriptionEASY-E4-AC-16RE1 Expansion Unit
DescriptionEASY-E4-AC-16RE1 Expansion Unit
Operating ambient temperature-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C
CondensationTake appropriate measures to prevent condensation
Storage [ϑ]-40 - +70 °C
relative humidityin accordance with IEC 60068-2-30, IEC 60068-2-78
5 - 95 %
Air pressure (operation)795 - 1080 hPa
DescriptionEASY-E4-AC-16RE1 Expansion Unit
Protection type (IEC/EN 60529, EN50178, VBG 4)IP20
VibrationsIn accordance with IEC 60068-2-6
constant amplitude 0.15 mm: 10 - 57
constant acceleration 2 g: 57 - 150 Hz
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms18 Impacts
Drop to IEC/EN 60068-2-31 [Drop height]50 mm
Free fall, packaged (IEC/EN 60068-2-32)0.3 m
Mounting positionVertical or horizontal
DescriptionEASY-E4-AC-16RE1 Expansion Unit
Overvoltage category/pollution degreeIII/2
Electrostatic discharge (ESD)
applied standard
nach IEC/EN 61000-4-2
Electrostatic discharge (ESD)
Air discharge
8 kV
Electrostatic discharge (ESD)
Contact discharge
6 kV
Electromagnetic fields (RFI) to IEC EN 61000-4-30.08 - 1.0 GHz: 10
1.4 - 2 GHz: 3
2.0 - 2.7 GHz: 1 V/m
Radio interference suppressionEN 61000-6-3 Class B
Burstaccording to IEC/EN 61000-4-4
Supply cables: 2
Signal cables: 2 kV
power pulses (Surge)according to IEC/EN 61000-4-5
1 kV (supply cables, symmetrical)
2 kV (supply cables, asymmetrical)
Immunity to line-conducted interference to (IEC/EN 61000-4-6)10 V
DescriptionEASY-E4-AC-16RE1 Expansion Unit
Clearance in air and creepage distancesnach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Insulation resistancein accordance with EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
DescriptionEASY-E4-AC-16RE1 Expansion Unit
DescriptionEASY-E4-AC-16RE1 Expansion Unit
DescriptionEASY-E4-AC-16RE1 Expansion Unit
Rated operational voltage [Ue]100 - 240V DC (-15/+10%)
100 - 240 DC (cULus: 100 -110 DC) (-15/+10%) V
Permissible range [Ue]85 - 264 V AC
85 - 264 V DC (cULus: 85 - 120 V DC)
Residual ripple≦ 5 %
Protection against polarity reversalyes
Frequency50/60 (± 5%) Hz
Voltage dips ≤ 20 ms at 100V AC
10 ms at 100V DC ms
Fuse≧ 1A (T) A
Power loss [P]Normally 11 W
DescriptionEASY-E4-AC-16RE1 Expansion Unit
DescriptionEASY-E4-AC-16RE1 Expansion Unit
DescriptionEASY-E4-AC-12RCX1 Expansion Unit
DescriptionEASY-E4-AC-16RE1 Expansion Unit
Number8
Potential isolationfrom power supply: no
between inputs: no
from the outputs: yes
to the base unit: yes
to the expansion units: yes
Rated operational voltage [Ue]100 - 240 V AC
100 - 240 V DC (cULus: 100 - 110 V DC) V
Input voltage [Ue]Condition 0: 0 - 40V AC/DC
Condition 1: 79–264 V AC/DC (cULus: 79–264 V AC/79–120 V DC) V
Rated frequency50/60 Hz
Input current at signal 1I1 - I8: 8 x 0.25 (at 115V AC, 60 Hz)
I1 - I8: 8 x 0.5 (at 230V AC, 50 Hz)
I1 - I8: 8 x 0.25 (at 115V DC)
I1 - I8: 8 x 0.5 (at 230V DC) mA
Deceleration timetype 39⁄32 (0 - > 1/1 -> 0, 50/60Hz) in AC
type 0.5 (0 - > 1/1 -> 0) in DC ms
Cable length40 (unshielded) m
DescriptionEASY-E4-AC-16RE1 Expansion Unit
DescriptionEASY-E4-AC-16RE1 Expansion Unit
Number8
Outputs in groups of1
Parallel switching of outputs for increased outputNot permitted
Protection of an output relayB16 circuit breaker or 8 A (T) fuse
Potential isolationSafe isolation according to EN 50178: 300 V AC
Basic isolation: 600 V AC
from power supply: yes
From the inputs: yes
between outputs: yes
to expansion devices: yes
Contacts
Conventional thermal current (10 A UL)
5 A
Contacts
Recommended for load: 12 V AC/DC
> 500 mA
Contacts
Rated impulse withstand voltage Uimp of contact coil
6 kV
Contacts
Rated operational voltage [Ue]
240 V AC
Rated insulation voltage [Ui]240 V AC
Safe isolation according to EN 50178300 between coil and contact
300 between two contacts V AC
Making capacity
AC–-15, 250 V AC, 3 A (600 ops./h) [Operations]
300000
Making capacity
DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations]
200000
Breaking capacity
AC-15, 250 V AC, 3 A (600 Ops./h) [Operations]
300000
Breaking capacity
DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations]
200000
Filament bulb load
1000 W at 230/240 V AC [Operations]
25000
Filament bulb load
500 W at 115/120 V AC [Operations]
25000
Fluorescent lamp load
Fluorescent lamp load 10 x 58 W at 230/240 V AC
With upstream electrical device [Operations]
25000
Fluorescent lamp load
Fluorescent lamp load 10 x 58 W at 230/240 V AC
Uncompensated [Operations]
25000
Fluorescent lamp load
Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated [Operations]
25000
Switching frequency
Mechanical operations
10 x 106
Switching frequency
Switching frequency
10 Hz
Switching frequency
Resistive load/lamp load
2 Hz
Switching frequency
Inductive load
0.5 Hz
UL/CSA
Uninterrupted current at 240 V AC
5 A
UL/CSA
Uninterrupted current at 24 V DC
5 A
UL/CSA
AC
Control Circuit Rating Codes (utilization category)
B 300 Light Pilot Duty
UL/CSA
AC
Max. rated operational voltage
300 V AC
UL/CSA
AC
max. thermal continuous current cos ϕ = 1 at B 300
5 A
UL/CSA
AC
max. make/break cos ϕ ≠ capacity 1 at B 300
3600/360 VA
UL/CSA
DC
Control Circuit Rating Codes (utilization category)
R 300 Light Pilot Duty
UL/CSA
DC
Max. rated operational voltage
300 V DC
UL/CSA
DC
Max. thermal uninterrupted current at R 300
1 A
UL/CSA
DC
Max. make/break capacity at R 300
28/28 VA
DescriptionEASY-E4-AC-16RE1 Expansion Unit
DescriptionEASY-E4-AC-16RE1 Expansion Unit
DescriptionEASY-E4-AC-16RE1 Expansion Unit
Static heat dissipation, non-current-dependent [Pvs]11 W
Operating ambient temperature min.-25 °C
Operating ambient temperature max.+55 °C
DescriptionEASY-E4-AC-16RE1 Expansion Unit
10.2 Strength of materials and parts
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIESMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
DescriptionEASY-E4-AC-16RE1 Expansion Unit
PLC's (EG000024) / Logic module (EC001417)
Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / Logic module (ecl@ss10.0.1-27-24-22-16 [AKE539014])
Supply voltage AC 50 Hz85 - 264 V
Supply voltage AC 60 Hz85 - 264 V
Supply voltage DC85 - 264 V
Voltage type of supply voltageAC/DC
Switching current5 A
Number of analogue inputs0
Number of analogue outputs0
Number of digital inputs8
Number of digital outputs8
With relay outputYes
Number of HW-interfaces industrial Ethernet0
Number of interfaces PROFINET0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Number of HW-interfaces Wireless0
Number of HW-interfaces other2
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for MODBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Radio standard UMTSNo
IO link masterNo
RedundancyNo
With displayNo
Degree of protection (IP)IP20
Basic deviceNo
ExpandableYes
Expansion deviceYes
With timerNo
Rail mounting possibleYes
Wall mounting/direct mountingYes
Front build in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsNo
Category according to EN 954-1None
SIL according to IEC 61508None
Performance level acc. EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Explosion safety category for gasNone
Explosion safety category for dustNone
Width71.5 mm
Height90 mm
Depth58 mm
DescriptionEASY-E4-AC-16RE1 Expansion Unit
UL File No. E205091
UL Category Control No. NRAQ/7
North America Certification UL listed
Degree of Protection IEC: IP20, UL/CSA Type: -
DescriptionEASY-E4-AC-16RE1 Expansion Unit
Product Dimensions

Product Accessories

Starter Pack
EASY-BOX-E4-UC1 Starter Pack

Starter Pack
EASY-BOX-E4-DC1 Starter Pack

Starter Pack
EASY-BOX-E4-AC1 Starter Pack


Software
EASYSOFT-SWLIC Software


10W Power Supply
PSL10E24RP 10W Power Supply

30W Power Supply
PSL30E24RP 30W Power Supply


60W Power Supply
PSL60E24RP 60W Power Supply

100W Power Supply
PSL100E24RP 100W Power Supply


Spare Parts
PSL100E24RP 100W Power Supply

Memory Card
PSL100E24RP 100W Power Supply