NZMB1-A125
Circuit Breaker
NZMB1-A125
Circuit Breaker
NZMB1-A125
Circuit Breaker
Description:
NZMB1-A125 Circuit-breaker NZM1, 3 pole, Switching capacity 400/415 V 50 Hz( Icu ): 25 kA, Rated current = rated uninterrupted current Rated current = rated uninterrupted current( In = Iu ): 125 A, Installation type: Fixed, Box terminal, Standard/Approval: IEC, Protective function: System and cable protection
NZMB1-A125
Technical Specifications
Main Specifications
Description | NZMB1-A125 Base Unit |
---|---|
Product range | Circuit-breaker |
Protective function | System and cable protection |
Standard/Approval | IEC |
Installation type | Fixed |
Release system | Thermomagnetic release |
Construction size | NZM1 |
Number of poles | 3 pole |
Standard equipment | Box terminal |
400/415 V 50 Hz [Icu ] | 25 kA |
Rated current = rated uninterrupted current [In = Iu] | 125 A |
Overload trip | 100 - 125 A |
Short-circuit releases [Irm
] Non-delayed [Ii = In x …] | 6 - 10 |
Short-circuit releases [Irm ] | 750 - 1250 A |
Description | NZMB1-A125 Base Unit |
---|---|
Rated current = rated uninterrupted current [In = Iu] | 125 A |
Rated surge voltage invariability [Uimp
] Main contacts | 6000 V |
Rated surge voltage invariability [Uimp
] Auxiliary contacts | 6000 V |
Rated operational voltage [Ue] | 440 V AC |
Overvoltage category/pollution degree | III/3 |
Rated insulation voltage [Ui ] | 690 V |
Use in unearthed supply systems | ≦ 440 V |
Description | NZMB1-A125 Base Unit |
---|---|
Rated short-circuit making capacity [Icm
] 240 V [Icm ] | 63 kA |
Rated short-circuit making capacity [Icm
] 400/415 V [Icm ] | 53 kA |
Rated short-circuit making capacity [Icm
] 440 V 50/60 Hz [Icm ] | 53 kA |
Rated short-circuit breaking capacity Icn [Icn
] Icu to IEC/EN 60947 test cycle O-t-CO [Icu] 240 V 50/60 Hz [Icu ] | 30 kA |
Rated short-circuit breaking capacity Icn [Icn
] Icu to IEC/EN 60947 test cycle O-t-CO [Icu] 400/415 V 50/60 Hz [Icu ] | 25 kA |
Rated short-circuit breaking capacity Icn [Icn
] Icu to IEC/EN 60947 test cycle O-t-CO [Icu] 440 V 50/60 Hz [Icu ] | 25 kA |
Rated short-circuit breaking capacity Icn [Icn
] Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] 240 V 50/60 Hz [Ics ] | 30 kA |
Rated short-circuit breaking capacity Icn [Icn
] Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] 400/415 V 50/60 Hz [Ics ] | 25 kA |
Rated short-circuit breaking capacity Icn [Icn
] Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] 440 V 50/60 Hz [Ics ] | 18.5 kA |
Rated short-circuit breaking capacity Icn [Icn ] | Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker. |
Utilization category to IEC/EN 60947-2 | A |
Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release) [Operations] | 20000 |
Lifespan, electrical AC-1 400 V 50/60 Hz [Operations] | 7500 |
Lifespan, electrical AC-1 415 V 50/60 Hz [Operations] | 7500 |
Lifespan, electrical Max. operating frequency | 120 Ops/h |
Total break time at short-circuit | < 10 ms |
Description | NZMB1-A125 Base Unit |
---|---|
Standard equipment | Box terminal |
Optional accessories | Screw connection Tunnel terminal connection on rear |
Round copper conductor Box terminal Solid | 1 x (10 - 16) 2 x (6 - 16) mm2 |
Round copper conductor Box terminal Stranded | 1 x (10 - 70) 3) 2 x (6-25) mm2 |
Round copper conductor Box terminal | 3) Up to 95 mm² can be connected depending on the cable manufacturer. |
Round copper conductor Tunnel terminal Solid | 1 x 16 mm2 |
Round copper conductor Tunnel terminal Stranded 1-hole | 1 x (25 - 95) mm2 |
Round copper conductor Bolt terminal and rear-side connection Direct on the switch Solid | 1 x (10 - 16) 2 x (6 - 16) mm2 |
Round copper conductor Bolt terminal and rear-side connection Direct on the switch Stranded | 1 x (10 - 70) 3) 2 x 25 mm2 |
Round copper conductor Bolt terminal and rear-side connection Direct on the switch | 3) Up to 95 mm² can be connected depending on the cable manufacturer. |
Al circular conductor Tunnel terminal Solid | 1 x 16 mm2 |
Al circular conductor Tunnel terminal Stranded Stranded | 1 x (25 - 95) mm2 |
Al circular conductor Bolt terminal and rear-side connection Direct on the switch Solid | 1 x (10 - 16) 2 x (10 - 16) mm2 |
Al circular conductor Bolt terminal and rear-side connection Direct on the switch Stranded | 1 x (25 - 35) 2 x (25 - 35) mm2 |
Cu strip (number of segments x width x segment thickness) Box terminal [min.] | 2 x 9 x 0.8 mm |
Cu strip (number of segments x width x segment thickness) Box terminal [max.] | 9 x 9 x 0.8 mm |
Copper busbar (width x thickness) [mm] Bolt terminal and rear-side connection Screw connection | M6 |
Copper busbar (width x thickness) [mm] Bolt terminal and rear-side connection Direct on the switch [min.] | 12 x 5 mm |
Copper busbar (width x thickness) [mm] Bolt terminal and rear-side connection Direct on the switch [max.] | 16 x 5 mm |
Control cables | 1 x (0.75 - 2.5) 2 x (0.75 - 1.5) mm2 |
Description | NZMB1-A125 Base Unit |
---|---|
Rated operational current for specified heat dissipation [In] | 125 A |
Equipment heat dissipation, current-dependent [Pvid] | 26.72 W |
Operating ambient temperature min. | -25 °C |
Operating ambient temperature max. | +70 °C |
Description | NZMB1-A125 Base Unit |
---|---|
10.2 Strength of materials and parts 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
10.2 Strength of materials and parts 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
10.2 Strength of materials and parts 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
10.2 Strength of materials and parts 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. |
10.2 Strength of materials and parts 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
10.2 Strength of materials and parts 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts 10.2.7 Inscriptions | Meets the product standard's requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard's requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
10.8 Connections for external conductors | Is the panel builder's responsibility. |
10.9 Insulation properties 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
10.9 Insulation properties 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
10.9 Insulation properties 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Description | NZMB1-A125 Base Unit |
---|---|
Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation protection (EC000228) | |
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection (ecl@ss10.0.1-27-37-04-09 [AJZ716013]) | |
Rated permanent current Iu | 125 A |
Rated voltage | 440 - 440 V |
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz | 25 kA |
Overload release current setting | 100 - 125 A |
Adjustment range short-term delayed short-circuit release | 0 - 0 A |
Adjustment range undelayed short-circuit release | 750 - 1250 A |
Integrated earth fault protection | No |
Type of electrical connection of main circuit | Frame clamp |
Device construction | Built-in device fixed built-in technique |
Suitable for DIN rail (top hat rail) mounting | No |
DIN rail (top hat rail) mounting optional | Yes |
Number of auxiliary contacts as normally closed contact | 0 |
Number of auxiliary contacts as normally open contact | 0 |
Number of auxiliary contacts as change-over contact | 0 |
With switched-off indicator | No |
With under voltage release | No |
Number of poles | 3 |
Position of connection for main current circuit | Front side |
Type of control element | Rocker lever |
Complete device with protection unit | Yes |
Motor drive integrated | No |
Motor drive optional | No |
Degree of protection (IP) | IP20 |
Description | NZMB1-A125 Base Unit |
---|---|
Characteristic curve | |
Characteristic curve | |
Let-Through Current | |
Characteristic curve | |
Let-Through Energy |
Description | NZMB1-A125 Base Unit |
---|---|
① Blow out area, minimum clearance to adjacent parts | |