Eaton Molded Case Circuit Breaker Series-C, J-Frame

Typical F-Frame (10–225 Amperes)

J-Frame (70–250 Amperes)

Product Description

  • All Eaton’s J-Frame circuit breakers are HACR rated
  • J-Frame circuit breakers are available as individual components (frame, trip unit, terminals), or factory assembled complete breakers
  • J-Frame circuit breakers with non-interchangeable trip units are suitable for reverse feed use

Types JD, HJD and JDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Maximum
Continuous
Ampere Rating
at 40°C
Standard Interrupting Capacity
600 Vac Rated
35 kAIC at 480 Vac
Factory Assembled
Circuit Consisting
of Frame, Trip Unit
and Terminals(1)
Part Number
High Interrupting Capacity
600 Vac Rated
65 kAIC at 480 Vac
Factory Assembled
Circuit Consisting
of Frame, Trip Unit
and Terminals(1)
Part Number
Ultra High Interrupting
Capacity Current
Limiting 600 Vac Rated
100 kAIC at 480 Vac
Factory Assembled
Circuit Consisting
of Frame, Trip Unit
and Terminals(1)
Part Number
Thermal-Magnetic
Trip Unit Only(1)
For Use with
Standard or High
or Ultra High
Interrupting Frames
Part Number
Standard
Terminals Only
Part
Number
Two-Pole
70 JD2070 HJD2070 JDC2070 JT2070T TA250KB(2)
90 JD2090 HJD2090 JDC2090 JT2090T
100 JD2100 HJD2100 JDC2100 JT2100T
125 JD2125 HJD2125 JDC2125 JT2125T
150 JD2150 HJD2150 JDC2150 JT2150T
175 JD2175 HJD2175 JDC2175 JT2175T
200 JD2200 HJD2200 JDC2200 JT2200T
225 JD2225 HJD2225 JDC2225 JT2225T
250 JD2250 HJD2250 JDC2250 JT2250T
Three-Pole
70 JD3070 HJD3070 JDC3070 JT3070T TA250KB(2)
90 JD3090 HJD3090 JDC3090 JT3090T
100 JD3100 HJD3100 JDC3100 JT3100T
125 JD3125 HJD3125 JDC3125 JT3125T
150 JD3150 HJD3150 JDC3150 JT3150T
175 JD3175 HJD3175 JDC3175 JT3175T
200 JD3200 HJD3200 JDC3200 JT3200T
225 JD3225 HJD3225 JDC3225 JT3225T
250 JD3250 HJD3250 JDC3250 JT3250T
Four-Pole(3)(4)
125 JD4125 HJD4125 JDC4125 JT4125T TA250KB(2)
150 JD4150 HJD4150 JDC4150 JT4150T
175 JD4175 HJD4175 JDC4175 JT4175T
200 JD4200 HJD4200 JDC4200 JT4200T
225 JD4225 HJD4225 JDC4225 JT4225T
250 JD4250 HJD4250 JDC4250 JT4250T

NOTES:
(1) Magnetic trip adjustable 5–10 times continuous ampere rating.
(2) Individually packed.
(3) Fully rated neutral pole with no protection.
(4) Neutral is in right pole.

Types JD, HJD and JDC Thermal-Magnetic Circuit Breakers—Frame Only

Standard Interrupting
Capacity
600 Vac Rated
35 kAIC at 480 Vac
Part Number
High Interrupting
Capacity
600 Vac Rated
65 kAIC at 480 Vac
Part Number
Ultra High Interrupting
Capacity Current Limiting
600 Vac Rated
100 kAIC at 480 Vac
Part Number
Two-Pole
JD2250F HJD2250F JDC2250F
Three-Pole
JD3250F HJD3250F JDC3250F
Four-Pole
JD4250F HJD4250F JDC4250F

Type JDB Thermal-Magnetic Circuit Breakers with Non- Interchangeable Thermal-Magnetic Trip Units Suitable for Reverse Feed Application

Maximum
Continuous
Ampere Rating
at 40°C
600 Vac Rated, 250 Vdc Complete Circuit Breaker
Without Line and Load Terminals
Part Number
With Standard Line and Load Terminals Only
Part Number
Two-Pole
70 JDB2070W JDB2070
90 JDB2090W JDB2090
100 JDB2100W JDB2100
125 JDB2125W JDB2125
150 JDB2150W JDB2150
175 JDB2175W JDB2175
200 JDB2200W JDB2200
225 JDB2225W JDB2225
250 JDB2250W JDB2250
Three-Pole
70 JDB3070W JDB3070
90 JDB3090W JDB3090
100 JDB3100W JDB3100
125 JDB3125W JDB3125
150 JDB3150W JDB3150
175 JDB3175W JDB3175
200 JDB3200W JDB3200
225 JDB3225W JDB3225
250 JDB3250W JDB3250

Molded Case Switches

Eaton’s molded case switches are used as compact switches in applications requiring high current switching capabilities. Molded case switches are constructed of circuit breaker components and are of the high instantaneous automatic type. Molded case switches are listed in accordance with Underwriters Laboratories Standard UL 489.

Maximum
Continuous
Ampere Rating
at 40°C
600 Vac Maximum, 250 Vdc
Complete Circuit Breaker Only Without
Line and Load Terminals
Standard
Terminals Only
Part Number
Part Number Suitable for Reverse Feed Use
Part Number
Two-Pole
250 JD2250KW JDB2250KW TA250KB(1)
HJD2250KW HJDB2250KW
Three-Pole
250 JD3250KW JDB3250KW TA250KB(1)
HJD3250KW HJDB3250KW
Four-Pole
250 JD4250KW JDB4250KW TA250KB(1)
HJD4250KW HJDB4250KW

NOTES:
(1) Individually packed.
Molded case switches may open above 2500 amperes.

Accessories Selection Guide and Ordering Information

Line and Load Terminals

Eaton’s line and load terminals provide wire connecting capabilities for specific ranges of continuous current ratings and wire types. All terminals comply with Underwriters Laboratories Standards UL 486A and UL 486B and CSA Standard C22.2 No. 65, or Electrical Bulletin 1165. Unless otherwise specified, JFrame circuit breaker line and load terminals are shipped separately for field installation.

The bottom of the standard TA250KB terminal contains a recess that is positioned over the J-Frame circuit breaker terminal conductor.

Ordering Information

J-Frame circuit breakers use Cu/AI terminals as standard. When optional copper-only terminals are required, order by catalog number. Specify if factory installation is required.

T250KB Terminal TA250KB
Terminal
(Standard)

Line and Load Terminals

Maximum
Breaker
Amperes
Terminal
Body
Material
Wire
Type
AWG Wire Range/
No. Conductors
Metric Wire
Range mm2
Pat
Number
Standard Cu/AI Pressure Terminals
250 Aluminum Cu/AI 4–350 kcmil 25–185 TA250KB
Optional Cu Pressure Terminals
250 Stainless Steel Cu 4–350 kcmil 25–185 T250KB