Eaton Molded Case Circuit Breaker Series-C, F-Frame

Typical F-Frame (10–225 Amperes)

Type ED Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Suitable for Reverse Feed

Maximum Continuous
Ampere Rating at 40°C
240 Vac Maximum, 125 Vdc
(Includes Terminals on Load End Only)
65 kAIC at 240 Vac
Two-Pole
Part Number
Three-Pole
Part Number
15 ED2015 ED3015
20 ED2020 ED3020
25 ED2025 ED3025
30 ED2030 ED3030
35 ED2035 ED3035
40 ED2040 ED3040
50 ED2050 ED3050
60 ED2060 ED3060
100 ED2100 ED3100
125 ED2125 ED3125
150 ED2150 ED3150
175 ED2175 ED3175
200 ED2200 ED3200
225 ED2225 ED3225

Type EDH Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Suitable for Reverse Feed

Maximum Continuous
Ampere Rating at 40°C
240 Vac Maximum, 125 Vdc
(Includes Terminals on Load End Only)
100 kAIC at 240 Vac
Two-Pole
Part Number
Three-Pole
Part Number
15
20
25
30
35
40
50
60
100 EDH2100 EDH3100
125 EDH2125 EDH3125
150 EDH2150 EDH3150
175 EDH2175 EDH3175
200 EDH2200 EDH3200
225 EDH2225 EDH3225

Type EDC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Suitable for Reverse Feed

Maximum Continuous
Ampere Rating at 40°C
240 Vac Maximum, 125 Vdc
(Includes Terminals on Load End Only)
200 kAIC at 240 Vac
Two-Pole
Part Number
Three-Pole
Part Number
15
20
25
30
35
40
50
60
100 EDC2100 EDC3100
125 EDC2125 EDC3125
150 EDC2150 EDC3150
175 EDC2175 EDC3175
200 EDC2200 EDC3200
225 EDC2225 EDC3225

Type EDB Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Suitable for Reverse Feed

Maximum Continuous
Ampere Rating at 40°C
240 Vac Maximum, 125 Vdc
(Includes Terminals on Load End Only)
22 kAIC at 240 Vac
Two-Pole
Part Number
Three-Pole
Part Number
100 EDB2100 EDB3100
110 EDB2110 EDB3110
125 EDB2125 EDB3125
150 EDB2150 EDB3150
175 EDB2175 EDB3175
200 EDB2200 EDB3200
225 EDB2225 EDB3225

Type EDS Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Suitable for Reverse Feed

Maximum Continuous
Ampere Rating at 40°C
240 Vac Maximum, 125 Vdc
(Includes Terminals on Load End Only)
42 kAIC at 240 Vac
Two-Pole
Part Number
Three-Pole
Part Number
100 EDS2100 EDS3100
110 EDS2110 EDS3110
125 EDS2125 EDS3125
150 EDS2150 EDS3150
175 EDS2175 EDS3175
200 EDS2200 EDS3200
225 EDS2225 EDS3225

Type EHD Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
(Includes Terminals on Load End Only)

Maximum Continuous
Ampere Rating at 40°C
277 Vac Maximum, 125 Vdc
14 kAIC at 277 Vac
480 Vac Maximum, 250 Vdc
14 kAIC at 480 Vac
Single-Pole
Part Number
Two-Pole
Part Number
Three-Pole
Part Number
10(1) EHD1010 EHD2010 EHD3010
15 EHD1015(2) EHD2015 EHD3015
20 EHD1020(2) EHD2020 EHD3020
25 EHD1025 EHD2025 EHD3025
30 EHD1030 EHD2030 EHD3030
35 EHD1035 EHD2035 EHD3035
40 EHD1040 EHD2040 EHD3040
45 EHD1045 EHD2045 EHD3045
50 EHD1050 EHD2050 EHD3050
60 EHD1060 EHD2060 EHD3060
70 EHD1070 EHD2070 EHD3070
80 EHD1080 EHD2080 EHD3080
90 EHD1090 EHD2090 EHD3090
100 EHD1100 EHD2100 EHD3100

NOTES:
(1) Not UL listed. 5 kAIC interrupting rating.
(2) UL listed for SWD applications, see NEC Article 240.83(d).

Type FDB Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
(Includes Terminals on Load End Only)

Maximum Continuous
Ampere Rating at 40°C
600 Vac Maximum, 250 Vdc
14 kAIC at 600 Vac
Single-Pole
Part Number
Two-Pole
Part Number
Three-Pole
Part Number
10(1) FDB2010 FDB3010 FDB4010
15 FDB2015 FDB3015 FDB4015
20 FDB2020 FDB3020 FDB4020
25 FDB2025 FDB3025 FDB4025
30 FDB2030 FDB3030 FDB4030
35 FDB2035 FDB3035 FDB4035
40 FDB2040 FDB3040 FDB4040
45 FDB2045 FDB3045 FDB4045
50 FDB2050 FDB3050 FDB4050
60 FDB2060 FDB3060 FDB4060
70 FDB2070 FDB3070 FDB4070
80 FDB2080 FDB3080 FDB4080
90 FDB2090 FDB3090 FDB4090
100 FDB2100 FDB3100 FDB4100
110 FDB2110 FDB3110 FDB4110
125 FDB2125 FDB3125 FDB4125
150 FDB2150 FDB3150 FDB4150

NOTES:
(1) Not UL listed. 5 kAIC interrupting rating.
(2) UL listed for SWD applications, see NEC Article 240.83(d).

Type FD Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
(Includes Terminals on Load End Only)

Maximum Continuous
Ampere Rating at 40°C
277 Vac Maximum, 125 Vdc
35 kAIC at 277 Vac
600 Vac Maximum, 250 Vdc
35 kAIC at 480 Vac
Single-Pole
Part Number
Two-Pole
Part Number
Three-Pole
Part Number
Four-Pole
Part Number
10(1) FD1010
15 FD1015(2) FD2015 FD3015 FD4015
20 FD1020(2) FD2020 FD3020 FD4020
25 FD1025 FD2025 FD3025 FD4025
30 FD1030 FD2030 FD3030 FD4030
35 FD1035 FD2035 FD3035 FD4035
40 FD1040 FD2040 FD3040 FD4040
45 FD1045 FD2045 FD3045 FD4045
50 FD1050 FD2050 FD3050 FD4050
60 FD1060 FD2060 FD3060 FD4060
70 FD1070 FD2070 FD3070 FD4070
80 FD1080 FD2080 FD3080 FD4080
90 FD1090 FD2090 FD3090 FD4090
100 FD1100 FD2100 FD3100 FD4100
110 FD1110 FD2110 FD3110 FD4110
125 FD1125 FD2125 FD3125 FD4125
150 FD1150 FD2150 FD3150 FD4150
175 FD2175 FD3175 FD4175
200 FD2200 FD3200 FD4200
225 FD2225 FD3225 FD4225

NOTES:
(1) Not UL listed. 5 kAIC interrupting rating.
(2) UL listed for SWD applications, see NEC Article 240.83(d).

Type HFD Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
(Includes Terminals on Load End Only)

Maximum Continuous
Ampere Rating at 40°C
277 Vac Maximum, 125 Vdc
65 kAIC at 277 Vac
600 Vac Maximum, 250 Vdc
65 kAIC at 480 Vac
Single-Pole
Part Number
Two-Pole
Part Number
Three-Pole
Part Number
Four-Pole
Part Number
15 HFD1015(1) HFD2015 HFD3015 HFD4015
20 HFD1020(1) HFD2020 HFD3020 HFD4020
25 HFD1025 HFD2025 HFD3025 HFD4025
30 HFD1030 HFD2030 HFD3030 HFD4030
35 HFD1035 HFD2035 HFD3035 HFD4035
40 HFD1040 HFD2040 HFD3040 HFD4040
45 HFD1045 HFD2045 HFD3045 HFD4045
50 HFD1050 HFD2050 HFD3050 HFD4050
60 HFD1060 HFD2060 HFD3060 HFD4060
70 HFD1070 HFD2070 HFD3070 HFD4070
80 HFD1080 HFD2080 HFD3080 HFD4080
90 HFD1090 HFD2090 HFD3090 HFD4090
100 HFD1100 HFD2100 HFD3100 HFD4100
110 HFD1110 HFD2110 HFD3110 HFD4110
125 HFD1125 HFD2125 HFD3125 HFD4125
150 HFD1150 HFD2150 HFD3150 HFD4150
175 HFD2175 HFD3175 HFD4175
200 HFD2200 HFD3200 HFD4200
225 HFD2225 HFD3225 HFD4225

NOTES:
(1) UL listed for SWD applications, see NEC Article 240.83(d).

Type FDC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
(Includes Terminals on Load End Only)

Maximum Continuous
Ampere Rating at 40°C
600 Vac Maximum, 250 Vdc
100 kAIC at 480 Vac
Two-Pole
Part Number
Three-Pole
Part Number
Four-Pole
Part Number
15 FDC2015 FDC3015 FDC4015
20 FDC2020 FDC3020 FDC4020
25 FDC2025 FDC3025 FDC4025
30 FDC2030 FDC3030 FDC4030
35 FDC2035 FDC3035 FDC4035
40 FDC2040 FDC3040 FDC4040
45 FDC2045 FDC3045 FDC4045
50 FDC2050 FDC3050 FDC4050
60 FDC2060 FDC3060 FDC4060
70 FDC2070 FDC3070 FDC4070
80 FDC2080 FDC3080 FDC4080
90 FDC2090 FDC3090 FDC4090
100 FDC2100 FDC3100 FDC4100
110 FDC2110 FDC3110 FDC4110
125 FDC2125 FDC3125 FDC4125
150 FDC2150 FDC3150 FDC4150
175 FDC2175 FDC3175 FDC4175
200 FDC2200 FDC3200 FDC4200
225 FDC2225 FDC3225 FDC4225

Types FDE, HFDE and FDCE Electronic Circuit Breakers with Non-Interchangeable Trip Units

Maximum
Ampere
Rating
Neutral
CT for LSG
and LSIG
LS
Part Number
LSI
Part Number
LSG
Part Number
LSIG
Part Number
IC Rating 35 kAIC at 480 Vac
80 CTF080 FDE308033 FDE308032 FDE308035 FDE308036
160 CTF160 FDE316033 FDE316032 FDE316035 FDE316036
225 CTF225 FDE322533 FDE322532 FDE322535 FDE322536
IC Rating 65 kAIC at 480 Vac
80 CTF080 HFDE308033 HFDE308032 HFDE308035 HFDE308036
160 CTF160 HFDE316033 HFDE316032 HFDE316035 HFDE316036
225 CTF225 HFDE322533 HFDE322532 HFDE322535 HFDE322536
IC Rating 100 kAIC at 480 Vac(1)
80 CTF080 FDCE308033 FDCE308032 FDCE308035 FDCE308036
160 CTF160 FDCE316033 FDCE316032 FDCE316035 FDCE316036
225 CTF225 FDCE322533 FDCE322532 FDCE322535 FDCE322536

NOTES:
(1) Check for availability.

FDE Electronic Breaker with Zone Selective Interlocking

Ampere
Rating
LSI w/ZSI
Part Number
LSIG w/ZSI
Part Number
35 kAIC at 480 Vac
80 FDE308032ZG FDE308036ZG
160 FDE316032ZG FDE316036ZG
225 FDE322532ZG FDE322536ZG
65 kAIC at 480 Vac
80 HFDE308032ZG HFDE308036ZG
160 HFDE316032ZG HFDE316036ZG
225 HFDE322532ZG HFDE322536ZG

Digitrip Electronic Trip Units

Circuit Breaker Type Frame Ratings
FDE, HFDE, FDCE 225 100, 110, 125, 150, 160, 175, 200, 225
FDE, HFDE, FDCE 160 60, 70, 80, 90, 100, 125, 150, 160
FDE, HFDE, FDCE 80 15, 20, 30, 40, 50, 60, 70, 80

Molded Case Switches

Eaton’s molded case switches are used as compact switches in applications requiring high current switching capabilities. Molded case switches are constructed of circuit breaker components and are of the high instantaneous automatic type. Molded case switches are listed in accordance with Underwriters Laboratories Standard UL 489. (NOTE: Molded case switches will open above 1800 amperes.)

Maximum Continuous
Ampere Rating at 40°C
Complete Circuit Breaker with Load Side Terminals Only
480 Vac Maximum, 250 Vdc 600 Vac Maximum, 250 Vdc
Part Number Part Number Part Number
Two-Pole
100 EHD2100K FD2100K HFD2100K
150 FD2150K HFD2150K
225 FD2225K HFD2225K
Three-Pole
100 EHD3100K FD3100K HFD3100K
150 FD3150K HFD3150K
225 FD3225K HFD3225K
Four-Pole
100 FD4100K HFD4100K
150 FD4150K HFD4150K
225 FD4225K HFD4225K

Accessories and Ordering Information

Breaker Mount Ammeter(1)

Description Part Number
Breaker Mount Ammeter DIGIVIEW

Line and Load Terminals

Line and load terminals provide wire connecting capabilities for specific ranges of continuous current ratings and wire types. Except as noted, terminals comply with Underwriters Laboratories Standards UL 486A and UL 486B. Unless otherwise specified, F-Frame circuit breakers are factory equipped with load terminals only.

Ordering Information

F-Frame circuit breakers and molded case switches have load terminals only as standard equipment. When standard line-end terminals (same as standard load-end terminals) are required, add Suffix L to the circuit breaker catalog number. When nonstandard or optional line and/ or load terminals are required, order by style number. Specify if factory installation is required.

Line and Load Terminals

Maximum
Breaker
Amperes
Terminal Body Material Wire Type AWG Wire
Range
Metric Wire
Range mm2
Package of Three Terminals
Part Number
Standard Pressure Type Terminals
20 (EHD) Steel Cu/AI 14—10 2.5—4 3T20FB(2)
100 Steel Cu/AI 14—1/0 2.5—50 3T100FB
225 Aluminum Cu/AI 4—4/0 25—95 3TA225FD
Optional Pressure Terminals
50 Aluminum Cu/AI 14—4 2.5—25 3TA50FB(2)
100 Aluminum Cu/AI 14—1/0 2.5—50 3TA100FD
200 Stainless steel Cu 4—4/0 25—95 3T150FB
225 Copper Cu 4—4/0 25—95 3T225FD
225 Aluminum Cu/AI 6—300 kcmil 16—150 3TA225FDK(3)

NOTES:
(1) Use on FDE, HFDE and FDCE electronic trip only.
(2) Not for use with ED, EDH, EDC breakers.
(3) Includes terminal shield kit. Adds approximately 3 inches (76.2) to breaker height. Available for use on three-pole breaker only.

Line and Load Terminals

Assemble wire clamp to bottom of conductor as shown. Insert collar enclosing conductor as shown. Locate nut on top of conductor and tighten securely with screw and washer. Caution: Collar must surround conductor. Insert collar enclosing conductor and center on extrusion on collar. Install clip with legs on top of conductor and snap end around bottom of collar.
Assemble collar on top of conductor as shown. Tighten securely with screw and washer. Collar slides onto conductor and is held in position by a screw and lockwasher. Assemble collar on top of conductor as shown. Tighten securely with screw and washer. Terminal shield must be used with this collar.
Note: For 185 mm2, use 3TA225FDK1.