Classic Mining Service Circuit Breakers

Breaker
Type
Frame
Style
Numbers(1)(2)
Poles Amperes Trip
Type
Accessories
(Included in Frame)
Magnetic
Trip Range,
Amperes(3)
KAM 2609D60G64 2 180 M None 200—400
1291C26G07 2 180 M UVR(4) 200—400
2609D60G66 2 180 M Standard shunt trip(3) 200—400
1291C26G01 2 225 TM UVR(4) 300—700
1291C26G02 2 225 TM UVR(4) 500—1000
2609D60G67 3 180 M None 200—400
1291C26G08 3 180 M UVR(4) 200—400
2609D60G69 3 180 M Standard shunt trip(3) 200—400
5685D48G75 3 225 TM None 300—700
5685D48G74 3 225 TM None 500—1000
1291C26G03 3 225 TM UVR(4) 300—700
1291C26G04 3 225 TM UVR(4) 500—1000
2609D60G01 3 225 TM Standard shunt trip(3) 300—700
2609D60G02 3 225 TM Standard shunt trip(3) 500—1000
2609D60G40 3 225 M None 300—700
2609D60G41 3 225 M None 500—700
1291C26G05 3 225 M UVR(4) 300—700
1291C26G06 3 225 M UVR(4) 500—1000
LAM 1291C32G01 2 400 TM UVR(4) 500—1000
2609D60G61 2 400 M Shunt trip (48 Vdc) 750—1500
1291C32G03 3 400 TM UVR(4) 500—1000
5685D48G73 3 400 TM None 800—1600
1291C32G02 3 400 TM UVR(4) 800—1600
2609D60G03 3 400 TM Standard shunt trip(4) 800—1600
2609D60G44 3 400 M None 800—1600
1291C32G04 3 400 M UVR(4) 800—1600
MAM 2609D60G17 2 600 TM UVR(3) 750—1500
2609D60G18 2 800 TM UVR(3) 1000—2000
2609D60G63 3 400 TM UVR(3) 2000—4000
5685D48G72 3 600 TM None 1500—3000
2609D60G19 3 600 TM UVR(3) 1500—3000
2609D60G04 3 600 TM Standard shunt trip(3) 1500—3000
2609D60G05 3 800 TM Standard shunt trip(3) 2000—4000
5685D48G71 3 800 TM None 2000—4000
2609D60G20 3 800 TM UVR(3) 2000—4000
2609D60G46 3 800 M None 1500—3000
2609D60G47 3 800 M UVR(3) 1500—3000
2609D60G48 3 800 M None 2000—4000
2609D60G49 3 800 M UVR(3) 2000—4000
NBM 1229C37G13 2 1000 TM UVR(4) 1500—3000
1229C37G14 2 1200 TM UVR(4) 2000—4000
1227C36G10 3 1000 TM None 2500—5000
1229C37G15 3 1000 TM UVR(4) 2500—5000
1227C36G13 3 1000 TM Standard shunt trip(3) 2500—5000
1227C36G14 3 1200 TM Standard shunt trip(3) 2500—5000
1227C36G09 3 1200 TM None 2500—5000
1229C37G16 3 1200 TM UVR(4) 2500—5000
1227C36G19 3 1200 M None 2500—5000
1229C37G17 3 1200 M UVR(3) 2500—5000

NOTES:
(1) Terminals not included in style number.
(2) All breakers listed are complete with accessories indicated.
(3) Rated 120 volts/60 Hz: undervoltage release is handle reset type.
(4) UVR is auto-reset type, 120 Vac
M = magnetic only; TM = thermal-magnetic.

1000 Volt Classic Mining Service Circuit Breakers

Breaker
Type
Frame
Style
Numbers
Poles Amperes Trip
Type
Accessories
(Included in Frame)
Magnetic
Trip Range,
Amperes 1
HKAM 2609D60G70 3 180 M None 200—400
1291C26G16 3 180 M UVR(2) 200—400
5685D48G87 3 225 TM None 300—700
1291C26G12 3 225 TM UVR(2) 300—700
5685D48G86 3 225 TM None 500—1000
1291C26G13 3 225 TM UVR(2) 500—1000
1291C26G14 3 225 M UVR(2) 300—700
1291C26G15 3 225 M UVR(2) 500—1000
HLAM 5685D48G85 3 400 TM None 800—1600
1291C32G07 3 400 TM UVR(2) 800—1600
1291C32G09 3 400 M UVR(2) 800—1600
HMAM 5685D48G84 3 600 TM None 1500—3000
2609D60G28 3 600 TM UVR(3) 1500—3000
5685D48G83 3 800 TM None 2000—4000
2609D60G29 3 800 TM UVR(3) 2000—4000
2609D60G57 3 800 M UVR(3) 1500—3000
2609D60G58 3 800 M UVR(3) 2000—4000
HNBM 1227C36G12 3 1000 TM None 2500—5000
1229C37G19 3 1000 TM UVR(2) 2500—5000
1227C36G11 3 1200 TM None 2500—5000
1229C37G20 3 1200 TM UVR(2) 2500—5000
1229C37G18 3 1200 M UVR(2) 2500—5000

NOTES:
(1) The magnetic trip range does not change when rating plug is changed.
(2) 120 volt, 60 Hz electrical reset type.
(3) Rated 120 volts, 60 Hz; undervoltage release is handle reset type.
M = magnetic only; TM = thermal-magnetic.

Classic Mining Service Breaker Frames Only

Breaker
Type
Frame Size,
Amperes
Number
of Poles
Style
Numbers
KAM(1) 225 2 2602D86G11
225 3 2602D86G12
KAMH(1) 225 2 2602D86G13
225 3 2602D86G14
HKAM(1) 225 3 1264C99G05
LAM(2) 400 2 2602D99G05
400 3 2602D99G06
LAMH(2) 400 2 2602D99G07
400 3 2602D99G08
HLAM(2) 400 3 1264C99G02
LAM3600F 600 3 2603D48G07
LAMH3600F 600 3 2603D48G08
HLAM3600F 600 3 2603D48G09
MAM(2) 800 2 2600D43G11
800 3 2600D43G12
MAMH(2) 800 2 2600D43G13
800 3 2600D43G14
HMAM(2) 800 3 1264C99G03
NBM(2) 1200 2 2610D64G07
1200 3 2610D64G08
NBMH(2) 1200 2 2610D64G09
1200 3 2610D64G10
HNBM(2) 1200 3 2610D64G13

Trip Units for Classic Mining Circuit Breakers

Breaker
Type
Conductor
Size
Magnetic
Trip Range,
Amperes
Maximum
Continuous
Amperes
Thermal-Magnetic
Three-Pole(3)
Style Numbers
Magnetic Only
Three-Pole
Style Numbers
HKAM #6 150—400 180 2609D99G22
#4—#3 300—700 225 5685D48G40 2611D75G01
#4—#1 500—1000 225 5685D48G34 2611D75G02
HLAM #4—#1 750—1500 400 5685D48G97 2609D99G21
#2—#2/0 800—1600 400 5685D48G28 2611D75G03
HLAM600 #2—2/0 750—1500 600 2609D99G20
2/0—500 kcmil 1500—3000 600 2609D99G19
HMAM #2—#2/0 750—1500 600
2/0—500 kcmil 1500—3000 600 5685D48G22 2611D75G04 —
#1—3/0 1000—2000 800
3/0—500 kcmil 2000—4000 800 5685D48G16 2611D75G05
HNBM 2/0—500 kcmil 1500—3000 1000
4/0—500 kcmil 2500—5000 1000 5685D48G10
3/0—500 kcmil 2000—4000 1200
4/0—500 kcmil 2500—5000 1200 5685D48G04 2611D75G07

NOTES:
(1) Frame modified for left-hand mounting of UVR attachment.
(2) Frame modified for right-hand mounting of UVR attachment.
(3) Three-pole trip units only are suitable for replacement in 1000 volt mining service circuit breakers.
(4) 800 amperes.

Terminals For Classic Mining Service Breakers

Terminals are UL listed for wire type and range listed below. When used with aluminum conductors, use joint compound.

Breaker
Type
Terminal
Type
Maximum
Amperes
Package of 3
Line Terminals
Style Number
Wire Range,
Type
FBM, HFBM Style pressure type terminals 100 624B100G02 #14—1/0 Al/Cu
Optional Al/Cu pressure terminals 50 624B100G10 #14—#4 Al/Cu
100 624B100G17 # 4—4/0 Al/Cu

Terminals For Mining Service Breakers

Breaker Type Terminal Type Maximum
Amperes
Terminal Wire Range, Type
Number of Cables
KAM, HKAM Standard pressure terminals (copper only) 225 T225LA (1) #6—350 kcmil
Optional Al/Cu pressure terminals 225 TA225LA1 (1) #6—350 kcmil Cu, or (1) #4—350 kcmil Al
LAM Standard copper pressure terminals 225 T225LA (1) #6—350 kcmil Cu
400 T401LA (1) #4—250 kcmil Cu plus (1) 3/0—600 kcmil Cu
Optional Al/Cu pressure terminals 225 TA225LA1 (1) #6—350 kcmil Cu, or (1) #4—350 kcmil Al
400 TA400LA1 (1) #4—250 kcmil Al/Cu, plus (1) 3/0—600 kcmil Al/Cu
400 TA401LA (1)600—750 kcmil Al
LAM-600, LAMH-600, HLAM-600 Standard copper pressure terminals 600 T600LA (2)250—500 kcmil Cu
Optional Al/Cu pressure terminals 600 TA600LA (2) 250—500 kcmil Al/Cu
MAM, HMAM, MAMH Standard copper pressure terminals 350 T350MA (1)#1—600 kcmil Cu
600 T600MA1 (2)2/0—500 kcmil Cu
800 T800MA1 (3)3/0—300 kcmil Cu
Optional Al/Cu pressure terminals 600 TA700MA1 (2) #1—500 kcmil Al/Cu
800 TA800MA2 (3) 3/0—400 kcmil Al/Cu
800 TA801MA (2) 500—750 kcmil Al/Cu
NBM, HNBM, NBMH Standard copper pressure terminals 1000 T1000NB1 (3) 3/0—500 kcmil Cu
1200 T1200NB1 (4) 3/0—400 kcmil Cu
Optional Al/Cu pressure terminals 1000 TA1000NB1 (3) 3/0—400 kcmil Al/Cu
1200 TA1200NB1 (4) 4/0—500 kcmil Al/Cu
1200 TA1201NB1 (3) 500—750 kcmil Al/Cu

Let our expert sales staff guide you through finding the right products to fit your needs. CALL 866-595-9616.