BUY HERE
CALL NOW
IN STOCK
866.595.9616

EATON 30 mA Ground Fault (Earth Leakage) Module

EATON Motor Protector Circuit Breakers (MPCB)
Molded Case Circuit Breaker Over

30 mA Ground Fault (Earth Leakage) Module

Product Description

Eaton offers a three- and four pole 30 mA ground fault (earth leakage) protection module for Series G E-, J- and L-Frame breakers. UL-listed modules are available for E, J and L molded case circuit breakers (MCCBs). The modules are bottom mounted for circuits up to 125A (E-Frame) 160 and 250 amperes (J-Frame), or 400 and 630 amperes for the L-Frame.

The module is completely selfc ontained because the current sensor, relay and power supply are located inside the product. Current pickup settings are selectable from 0.03–10 amperes for all IEC-rated modules and E and J UL-listed module, and 0.03– 30 amperes for the L ULlisted modules. Time delays are also selectable from Instantaneous–1.0 seconds for 0.10 ampere settings and above. A current pickup setting of 0.03 amperes defaults to an Instantaneous time setting regardless of the time dial’s position. Two alarm contacts come as standard: a 50% pretrip and a 100% after trip, both based only on earth leakagecurrent levels.

UL-Rated LG-Frame Earth Leakage Module Faceplate

UL Earth-Leakage-Module-Faceplate

IEC-Rated LG-Frame Earth Leakage Module Faceplate

IEC Earth-Leakage-Module-Faceplate

EG-Frame Ground Fault Modules, UL-Rated (Bottom Mounted, 120–480 Vac, 50/60 Hz)(1)

Ampere
Rating
Number of
Poles
Part
Number
125 3 ELEBN3125G
125 4 ELEBN4125G

EG-Frame Earth Leakage Modules, IEC-Rated (Bottom Mounted, 230–415 Vac, 50/60 Hz)

Ampere
Rating
Number of
Poles
Part
Number
125 3 ELEBE3125G
125 4 ELEBE4125G

JG-Frame Ground Fault Modules, UL-Rated (Bottom Mounted, 120–480 Vac, 50/60 Hz)

Ampere
Rating
Number of
Poles
Part
Number
150 3 ELJBN3150W
150 4 ELJBN4150W
250 3 ELJBN3250W
250 4 ELJBN4250W

JG-Frame Earth Leakage Modules, IEC-Rated (Bottom Mounted, 230–415 Vac, 50/60 Hz)

Ampere
Rating
Number of
Poles
Part
Number
160 3 ELJBE3160W
160 4 ELJBE4160W
250 3 ELJBE3250W
250 4 ELJBE4250W

LG-Frame Ground Fault Modules, UL-Rated (Bottom Mounted, 120–480 Vac, 50/60 Hz)

Ampere
Rating
Number of
Poles
Part
Number
400 3 ELLBN3400W
400 4 ELLBN4400W
600 3 ELLBN3600W
600 4 ELLBN4600W

LG-Frame Earth Leakage Modules, IEC-Rated (Bottom Mounted, 230–415 Vac, 50/60 Hz)

Ampere
Rating
Number of
Poles
Part
Number
400 3 ELLBE3400W
400 4 ELLBE4400W
630 3 ELLBE3630W
630 4 ELLBE4630W

NOTES:
(1) Shunt trip and undervoltage release cannot be used in an EG breaker connected to an earth leakage module.