Eaton Molded Case Speciality Breakers
Speciality Breakers Index
Engine Generator Circuit Breakers
Eaton’s engine generator molded case circuit breakers are designed specifically for application on diesel engine powered standby generators where high interrupting circuit breakers are not required. The JG through NG breakers are equipped with a special trip unit, that includes standard thermal (overload) protection and special low magnetic pickup range (FG includes a fixed thermal-magnetic pickup)...
Direct Current Circuit Breakers
DC (direct current) systems and applications are becoming commonplace as alternative energy sources have expanded and the number of DC devices and data centers using DC power has swelled.
Eaton offers molded case circuit breakers and switches to meet circuit protection and switching requirements for a host of different DC end user requirements...
PVGard Solar Photovoltaic Circuit Breakers
Photovoltaic (PV) systems convert the energy of the sun into electrical power that is fed directly into the electric grid. Within the balance of system (BOS), direct current (DC) circuit breakers protect the wiring connected from the PV modules to the combiner or the inverter, while also behaving as a disconnect.
Eaton is a global leader in circuit protection and brings this expertise to bear in the photovoltaic market...
E2 Mining Service Breakers
State-of-the-art E2 miningservice breakers incorporate the rigid specifications and testing procedures developed by a focus group led by engineers from several large coal companies and Eaton design engineers. Additionally, the performance of these breakers was proven and verified during hundreds of hours of field testing in harsh mine environments.
E2 mining breakers are available in 600 Vac and l000Y/ 577 Vac. Interchangeable trip units can be used on either 600 or 1000 Vac frames...
Classic Mining Breakers
Classic mining service circuit breakers continue to be manufactured and are primarily applied to achieve an exact physical and electronic replacement of previously Cutler-Hammer installed Westinghouse equipment...
Add-On Ground Fault Protection—Type GFR
A Type GFR ground fault protection system, when properly installed on a grounded electrical system, will sense phase-to-ground fault currents. When the level of fault current is in excess of the pre-selected current pickup and time delay settings, the GFR relay will initiate a trip action of a disconnect device, which will open the faulted circuit and clear the fault....