EATON Molded Case Circuit Breakers Series-G, Frame Size - JG

Series-G, Frame Size-JG (63–250 Amperes)

Complete Breaker (Includes Frame, Trip Unit, Standard Terminals and Mounting Hardware)—IC Rating at 415/480 Volts

JG-Frame-IEC/CE/UL/CSA-25/25

Maximum Continuous Amperes Magnetic
Range
Two-Pole
Fixed Thermal, Adjustable Magnetic
Three-Pole
Fixed Thermal, Adjustable Magnetic
Adjustable Thermal, Adjustable Magnetic (1)
Four-Pole 0% (2)
Fixed Thermal, Adjustable Magnetic
Adjustable Thermal, Adjustable Magnetic (1)
70 350-700 JGE2070FAG JGE3070FAG - JGE4070FAG -
90 450-900 JGE2090FAG JGE3090FAG - JGE4090FAG -
100 500-1000 JGE2100FAG JGE3100FAG JGE3100AAG JGE4100FAG JGE4100AAG
125 625-1250 JGE2125FAG JGE3125FAG JGE3125AAG JGE4125FAG JGE4125AAG
150 750-1550 JGE2150FAG JGE3150FAG - JGE4150FAG -
160 800-1600 - - JGE3160AAG - JGE4160AAG
175 875-1750 JGE2175FAG JGE3175FAG - JGE4175FAG -
200 1000-2000 JGE2200FAG JGE3200FAG JGE3200AAG JGE4200FAG JGE4200AAG
225 1125-2250 JGE2225FAG JGE3225FAG - JGE4225FAG -
250 1250-2500 JGE2250FAG JGE3250FAG JGE3250AAG JGE4250FAG JGE4250AAG

JG-Frame—IEC/CE/UL/CSA—40/35, Two-Pole

Maximum Continuous Amperes Magnetic
Range
Two-Pole
Fixed Thermal, Adjustable Magnetic
Three-Pole
Fixed Thermal, Adjustable Magnetic
Adjustable Thermal, Adjustable Magnetic (1)
Four-Pole 0% (2)
Fixed Thermal, Adjustable Magnetic
Adjustable Thermal, Adjustable Magnetic (1)
70 350-700 JGS2070FAG JGS3070FAG - JGS4070FAG -
90 450-900 JGS2090FAG JGS3090FAG - JGS4090FAG -
100 500-1000 JGS2100FAG JGS3100FAG JGS3100AAG JGS4100FAG JGS4100AAG
125 625-1250 JGS2125FAG JGS3125FAG JGS3125AAG JGS4125FAG JGS4125AAG
150 750-1550 JGS2150FAG JGS3150FAG - JGS4150FAG -
160 800-1600 - - JGS3160AAG - JGS4160AAG
175 875-1750 JGS2175FAG JGS3175FAG - JGS4175FAG -
200 1000-2000 JGS2200FAG JGS3200FAG JGS3200AAG JGS4200FAG JGS4200AAG
225 1125-2250 JGS2225FAG JGS3225FAG - JGS4225FAG -
250 1250-2500 JGS2250FAG JGS3250FAG JGS3250AAG JGS4250FAG JGS4250AAG

JG-Frame—IEC/CE/UL/CSA—70/65

Maximum Continuous Amperes Magnetic
Range
Two-Pole
Fixed Thermal,
Adjustable Magnetic
Three-Pole
Fixed Thermal,
Adjustable Magnetic
Adjustable Thermal,
Fixed Magnetic (1)
Four-Pole 0% (2)
Fixed Thermal,
Adjustable Magnetic
Adjustable Thermal,
Fixed Magnetic (1)
70 350-700 JGH2070FAG JGH3070FAG - JGH4070FAG -
90 450-900 JGH2090FAG JGH3090FAG - JGH4090FAG -
100 500-1000 JGH2100FAG JGH3100FAG JGH3100AAG JGH4100FAG JGH4100AAG
125 625-1250 JGH2125FAG JGH3125FAG JGH3125AAG JGH4125FAG JGH4125AAG
150 750-1550 JGH2150FAG JGH3150FAG - JGH4150FAG -
160 800-1600 - - JGH3160AAG - JGH4160AAG
175 875-1750 JGH2175FAG JGH3175FAG - JGH4175FAG -
200 1000-2000 JGH2200FAG JGH3200FAG JGH3200AAG JGH4200FAG JGH4200AAG
225 1125-2250 JGH2225FAG JGH3225FAG - JGH4225FAG -
250 1250-2500 JGH2250FAG JGH3250FAG JGH3250AAG JGH4250FAG JGH4250AAG

JG-Frame—IEC/CE/UL/CSA—100/100, Current Limiting

Maximum
Continuous
Amperes
Magnetic
Range
Three-Pole
Fixed Thermal,
Adjustable Magnetic
Adjustable Thermal,
Adjustable Magnetic (1)
Four-Pole 0% (2)
Fixed Thermal,
Adjustable Magnetic
Adjustable Thermal,
Adjustable Magnetic (1)
70 350-700 JGC3070FAG - JGC4070FAG -
80 400-800 - JGC3080AAG - JGC4080AAG
90 450-900 JGC3090FAG - JGC4090FAG -
100 500-1000 JGC3100FAG JGC3100AAG JGC4100FAG JGC4100AAG
125 625-1250 JGC3125FAG JGC3125AAG JGC4125FAG JGC4125AAG
150 750-1550 JGC3150FAG - JGC4150FAG -
160 800-1600 - JGC3160AAG - JGC4160AAG
175 875-1750 JGC3175FAG - JGC4175FAG -
200 1000-2000 JGC3200FAG JGC3200AAG JGC4200FAG JGC4200AAG
225 1125-2250 JGC3225FAG - JGC4225FAG -
250 1250-2500 JGC3250FAG JGC3250AAG JGC4250FAG JGC4250AAG

JG-Frame—IEC/CE/UL/CSA—150/150, Current Limiting

Maximum
Continuous
Amperes
Magnetic
Range
Three-Pole
Fixed Thermal,
Adjustable Magnetic
Adjustable Thermal,
Adjustable Magnetic (1)
Four-Pole 0% (2)
Fixed Thermal,
Adjustable Magnetic
Adjustable Thermal,
Adjustable Magnetic (1)
70 350-700 JGU3070FAG - JGU4070FAG -
80 400-800 - JGU3080AAG - JGU4080AAG
90 450-900 JGU3090FAG - JGU4090FAG -
100 500-1000 JGU3100FAG JGU3100AAG JGU4100FAG JGU4100AAG
125 625-1250 JGU3125FAG JGU3125AAG JGU4125FAG JGU4125AAG
150 750-1550 JGU3150FAG - JGU4150FAG -
160 800-1600 - JGU3160AAG - JGU4160AAG
175 875-1750 JGU3175FAG - JGU4175FAG -
200 1000-2000 JGU3200FAG JGU3200AAG JGU4200FAG JGU4200AAG
225 1125-2250 JGU3225FAG - JGU4225FAG -
250 1250-2500 JGU3250FAG JGU3250AAG JGU4250FAG JGU4250AAG

JG-Frame—IEC/CE/UL/CSA 200/200, Current Limiting

Maximum
Continuous
Amperes
Magnetic
Range
Three-Pole
Fixed Thermal,
Adjustable Magnetic
Adjustable Thermal,
Adjustable Magnetic (1)
Four-Pole (2)
Fixed Thermal,
Adjustable Magnetic
Adjustable Thermal,
Adjustable Magnetic (1)
70 350-700 JGX3070FAG - JGX4070FAG -
80 400-800 - JGX3080AAG - JGX4080AAG
90 450-900 JGX3090FAG - JGX4090FAG -
100 500-1000 JGX3100FAG JGX3100AAG JGX4100FAG JGX4100AAG
125 625-1250 JGX3125FAG JGX3125AAG JGX4125FAG JGX4125AAG
150 750-1550 JGX3150FAG - JGX4150FAG -
160 800-1600 - JGX3160AAG - JGX4160AAG
175 875-1750 JGX3175FAG - JGX4175FAG -
200 1000-2000 JGX3200FAG JGX3200AAG JGX4200FAG JGX4200AAG
225 1125-2250 JGX3225FAG - JGX4225FAG -
250 1250-2500 JGX3250FAG JGX3250AAG JGX4250FAG JGX4250AAG

Molded Case Switches (3)

Notes:
(1) EC-EN 60947-2 only. Adjustment is 0.8 and 1.0.
(2) Change the fourth digit to 8 for adjustable 0–60% neutral protection, 9 for 0–100% neutral protection. Neutral is on LH side.
(3) Molded case switches will trip above2500 amperes.

Frame—IC Rating at 415/480 Volts

Maximum
Amperes
Two-Pole Three-Pole Four-Pole 0%
25/25
250 JGE2250NN JGE3250NN JGE4250NN
40/35
250 JGS2250NN JGS3250NN JGS4250NN
70/65
250 JGH2250NN JGH3250NN JGH4250NN
100/100 Current Limiting Per UL 489
250 JGC3250NN JGC4250NN
150/150 Current Limiting Per UL 489
250 JGU3250NN JGU4250NN
200/200 Current Limiting Per UL 489
250 JGX3250NN JGX4250NN
25/25 100% Rated Per UL 489 (2)
250 JGE3250NNC
40/35 100% Rated Per UL 489 (2)
250 JGS3250NNC
70/65 100% Rated Per UL 489 (2)
250 JGH3250NNC

Thermal-Magnetic Trip Unit

Notes:
(1) Standard line and load terminals.
(2) Components—100% rated frame.
(3) Adjustable thermal trip units are typically used in IEC markets and are not UL or CSA listed.

Electronic Trip Units

JG Electronic Trip Units

Header Key:

L – Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
S – Adjustable Short Delay Pickup with Adjustable Short Delay Time (I2t or Flat Response)
I – Adjustable Instantaneous Pickup
G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2 t or Flat Response)
A – Adjustable Ground Fault Alarm with Adjustable Ground Fault Time Delay (I 2 t or Flat Response)

Plug-In Test Kit

Voltage Rating Part Number
120 Vac MTST120V
230 Vac MTST230V

Breaker Mount Ammeter

Description Part Number
Breaker mount ammeter DIGIVIEW

Notes:
(1) For use on a three-pole breaker used in a four-wire system if ground fault protection for the neutral is required.
(2) Neutral protection 4 = 0%, 6 = 60%, 7 = 100% electronic trip unit neutral protection is not adjustable.

Long time pickup—selectable via dial setting.
50 ampere settings—50, 45, 40, 32, 30, 25, 20.
100 ampere settings—100, 90, 80, 70, 63, 50, 45, 40.
160 ampere settings—160, 150, 125, 110, 100, 90, 80, 63.
250 ampere settings—250, 225, 200, 175, 160, 150, 125, 100.
Adjustable long time delay—2–24 seconds at 6 x lr.
Adjustable short time delay—Inst., 120, 300 ms

Complete Breaker with Electronic Trip Units

IEC/UL/CSA—25/25

IEC/UL/CSA—40/35

IEC/UL/CSA—70/65

IEC/UL/CSA—100/100, Current Limiting Per UL 489

IEC/UL/CSA—150/150, Current Limiting Per UL 489

IEC/UL/CSA—200/200, Current Limiting Per UL 489

Notes:
(1) Required for four-wire systems if neutral protection is required.
(2) Neutral protection 4 = 0%, 6 = 60%, 7 = 100% electronic trip unit neutral protection is not adjustable.

JG 100% Rated Electronic Trip Unit Circuit Breaker

IEC/UL/CSA—25/25

IEC/UL/CSA-40/35

IEC/UL/CSA—70/65

Notes:
(1) Required for four-wire systems if neutral protection is required.

JG 100% Rated Circuit Breaker—Thermal-Magnetic Trip Unit

Complete Breaker (Includes Frame, Trip Unit, Standard Terminals and Mounting Hardware)—IC Rating at 415/480 Volts

JG-Frame—IEC/CE/UL/CSA—25/25

Maximum
Continuous
Amperes
Magnetic
Range
Three-Pole
Fixed Thermal,
Adjustable Magnetic
70 350-700 JGE3070FAGC
90 450-900 JGE3090FAGC
100 500-1000 JGE3100FAGC
125 625-1250 JGE3125FAGC
150 750-1550 JGE3150FAGC
160 800-1600 -
175 875-1750 JGE3175FAGC
200 1000-2000 JGE3200FAGC
225 1125-2250 JGE3225FAGC
250 1250-2500 JGE3250FAGC

JG-Frame—IEC/CE/UL/CSA—40/35

Maximum Continuous Amperes Magnetic
Range
Three-Pole
Fixed Thermal, Adjustable Magnetic
70 350-700 JGS3070FAGC
90 450-900 JGS3090FAGC
100 500-1000 JGS3100FAGC
125 625-1250 JGS3125FAGC
150 750-1550 JGS3150FAGC
160 800-1600 -
175 875-1750 JGS3175FAGC
200 1000-2000 JGS3200FAGC
225 1125-2250 JGS3225FAGC
250 1250-2500 JGS3250FAGC

JG-Frame—IEC/CE/UL/CSA—70/65

Maximum
Continuous
Amperes
Magnetic
Range
Three-Pole
Fixed Thermal,
Adjustable Magnetic
70 350-700 JGH3070FAGC
90 450-900 JGH3090FAGC
100 500-1000 JGH3100FAGC
125 625-1250 JGH3125FAGC
150 750-1550 JGH3150FAGC
160 800-1600 -
175 875-1750 JGH3175FAGC
200 1000-2000 JGH3200FAGC
225 1125-2250 JGH3225FAGC
250 1250-2500 JGH3250FAGC

Accessories Selection Guide and Ordering Information

T250FJ TA250FJ Endcap Kit Control Wire
Terminal Kit
Rear Fed
Terminals
Multiwire
Connectors

Load and Line Terminals

Maximum
Breaker
Amperes
Terminal
Body
Material
Wire Type Metric Wire
Range mm 2
AWG Wire
Range/ Number
of Conductors
Part
Number
Standard Pressure Type Terminals
250 Stainless Steel Cu 25–185 #4–350 (1) T250FJ (1)
250 Aluminum Cu/Al 10–185 #8–350 (1) TA250FJ (1)(2)

JG-Frame circuit breakers include aluminum terminals TA250FJ as standard. When optional stainless steel only terminals are required, order by catalog number.

Endcap Kits

Number of
Poles
Part Number
Metric Imperial
3 FJ3RTWK FJ3RTDK
4 FJ4RTWK FJ4RTDK

Endcap kits are used on J250-Frame breaker to connect busbar or similar electrical connections. Includes hardware.

Control Wire Terminal Kit

Description Part Number
Package of 14 (priced individually) FJCWTK

For use with aluminum or copper terminals only.

Rear Fed Terminals

Description Wire Size
Range AWG Cu
Part Number
250 #4–350 kcmil TA250JGRF
3TA250JGRF

Rear fed terminals allow the cable to connect to the breaker from the back instead of the top. Terminal shields or interphase barriers are included with each rear fed terminal kit (depending on frame size). When catalog number starts with a 3, it indicates a kit with three terminals in each kit. Catalog number beginning with a TA indicates one terminal.

Base Mounting Hardware

Base mounting hardware is included with a circuit breaker or molded case switch. (Included with breaker.) If required separately, order 66A2546G02.

Terminal Shields IP30

Location Number of Poles Part Number
Line or Load 2, 3 FJTS3K
4 FJTS4K

Interphase Barriers

Number
of Poles
Part Number
3 FJIPBK (3)
4 FJIPBK4 (3)

Multiwire Connectors

Field-installed multiwire connectors for the load side (OFF) end terminals are used to distribute the load from the circuit breaker to multiple devices without the use of separate distribution terminal blocks.

Multiwire lug kits include terminal shield, mounting hardware, insulators and tin-plated aluminum connectors to replace three mechanical load lugs. UL listed as used on the load side (OFF) end.

JG-Frame Multiwire Connectors Ordering Information (Package of 3)

Maximum
Amperes
Wires per
Terminal
Wire Size
Range AWG Cu
Kit
Part Number
250 3 14-2 3TA250FJ3
259 6 14-6 3TA250FJ6

Notes:
(1) Individually packed.
(2) Standard line and load.
(3) Individually priced.