Notes:
(1) 16, 32, 63 and 160A are not UL listed ratings.
(2) Adjustable thermal are not UL listed.
(3) Change the fourth digit to 7 for 100% neutral protection. Neutral is on the LH side.
Notes:
(1) 16, 32, 63 and 160A are not UL listed ratings.
(2) Adjustable thermal are not UL listed.
(3) Change the fourth digit to 7 for 100% neutral protection. Neutral is on the LH side.
Notes:
(1) 16, 32, 63 and 160A are not UL listed ratings.
(2) Adjustable thermal are not UL listed.
(3) Change the fourth digit to 7 for 100% neutral protection. Neutral is on the LH side.
Notes:
(1) 16, 32, 63 and 160A are not UL listed ratings.
(2) Adjustable thermal are not UL listed.
(3) Change the fourth digit to 7 for 100% neutral protection. Neutral is on the LH side.
Maximum
Continuous Amps at 40° C (1) |
Three-Pole
Fixed Thermal, Fixed Magnetic |
Adjustable
(2)
Thermal, Fixed Magnetic |
Four-Pole 0% Protected Neutral
(3)
|
|
Fixed Thermal,
Fixed Magnetic |
Adjustable
(2)
Thermal,
Fixed Magnetic |
|||
15 | EGC3015FFG | - | EGC7015FFG | - |
16 | EGC3016FFG | - | EGC7016FFG | - |
20 | EGC3020FFG | EGC3020AFG | EGC7020FFG | EGC7020AFG |
25 | EGC3025FFG | EGC3025AFG | EGC7025FFG | EGC7025AFG |
30 | EGC3030FFG | - | EGC7030FFG | - |
32 | EGC3032FFG | EGC3032AFG | EGC7032FFG | EGC7032AFG |
35 | EGC3035FFG | - | EGC7035FFG | - |
40 | EGC3040FFG | EGC3040AFG | EGC7040FFG | EGC7040AFG |
45 | EGC3045FFG | - | EGC7045FFG | - |
50 | EGC3050FFG | EGC3050AFG | EGC7050FFG | EGC7050AFG |
60 | EGC3060FFG | - | EGC7060FFG | - |
63 | EGC3063FFG | EGC3063AFG | EGC7063FFG | EGC7063AFG |
70 | EGC3070FFG | - | EGC7070FFG | - |
80 | EGC3080FFG | EGC3080AFG | EGC7080FFG | EGC7080AFG |
90 | EGC3090FFG | - | EGC7090FFG | - |
100 | EGC3100FFG | EGC3100AFG | EGC7100FFG | EGC7100AFG |
125 | EGC3125FFG | EGC3125AFG | EGC7125FFG | EGC7125AFG |
Part Number |
EGK3125KSG |
EGK7125KSG |
EGK3160KSG |
EGK7160KSG |
Notes:
(1) 16, 32, 63 and 160A are not UL listed ratings.
(2) Adjustable thermal are not UL listed.
(3) Change the fourth digit to 7 for 100% neutral protection. Neutral is on the LH side.
(4) Molded case switches may open above 1250A.
Maximum
Continuous Amps at 40°C |
Single-Pole
Fixed Thermal, Fixed Magnetic (1) |
Two-Pole
Fixed Thermal, Fixed Magnetic (2) |
Three-Pole
Fixed Thermal, Fixed Magnetic (3) |
15 | EGB1015FFB | EGB2015FFB | EGB3015FFB |
20 | EGB1020FFB | EGB2020FFB | EGB3020FFB |
25 | EGB1025FFB | EGB2025FFB | EGB3025FFB |
30 | EGB1030FFB | EGB2030FFB | EGB3030FFB |
35 | EGB1035FFB | EGB2035FFB | EGB3035FFB |
40 | EGB1040FFB | EGB2040FFB | EGB3040FFB |
45 | EGB1045FFB | EGB2045FFB | EGB3045FFB |
50 | EGB1050FFB | EGB2050FFB | EGB3050FFB |
60 | EGB1060FFB | EGB2060FFB | EGB3060FFB |
70 | EGB1070FFB | EGB2070FFB | EGB3070FFB |
80 | EGB1080FFB | EGB2080FFB | EGB3080FFB |
90 | EGB1090FFB | EGB2090FFB | EGB3090FFB |
100 | EGB1100FFB | EGB2100FFB | EGB3100FFB |
110 | EGB1110FFB | EGB2110FFB | EGB3110FFB |
125 | EGB1125FFB | EGB2125FFB | EGB3125FFB |
Maximum
Continuous Amps at 40°C |
Single-Pole
Fixed Thermal, Fixed Magnetic (1) |
Two-Pole
Fixed Thermal, Fixed Magnetic (2) |
Three-Pole
Fixed Thermal, Fixed Magnetic (3) |
15 | EGS1015FFB | EGS2015FFB | EGS3015FFB |
20 | EGS1020FFB | EGS2020FFB | EGS3020FFB |
25 | EGS1025FFB | EGS2025FFB | EGS3025FFB |
30 | EGS1030FFB | EGS2030FFB | EGS3030FFB |
35 | EGS1035FFB | EGS2035FFB | EGS3035FFB |
40 | EGS1040FFB | EGS2040FFB | EGS3040FFB |
45 | EGS1045FFB | EGS2045FFB | EGS3045FFB |
50 | EGS1050FFB | EGS2050FFB | EGS3050FFB |
60 | EGS1060FFB | EGS2060FFB | EGS3060FFB |
70 | EGS1070FFB | EGS2070FFB | EGS3070FFB |
80 | EGS1080FFB | EGS2080FFB | EGS3080FFB |
90 | EGS1090FFB | EGS2090FFB | EGS3090FFB |
100 | EGS1100FFB | EGS2100FFB | EGS3100FFB |
110 | EGS1110FFB | EGS2110FFB | EGS3110FFB |
125 | EGS1125FFB | EGS2125FFB | EGS3125FFB |
Maximum
Continuous Amps at 40 C |
Single-Pole
Fixed Thermal, Fixed Magnetic (1) |
Two-Pole
Fixed Thermal, Fixed Magnetic (2) |
Three-Pole
Fixed Thermal, Fixed Magnetic (3) |
15 | EGH1015FFB | EGH2015FFB | EGH3015FFB |
20 | EGH1020FFB | EGH2020FFB | EGH3020FFB |
25 | EGH1025FFB | EGH2025FFB | EGH3025FFB |
30 | EGH1030FFB | EGH2030FFB | EGH3030FFB |
35 | EGH1035FFB | EGH2035FFB | EGH3035FFB |
40 | EGH1040FFB | EGH2040FFB | EGH3040FFB |
45 | EGH1045FFB | EGH2045FFB | EGH3045FFB |
50 | EGH1050FFB | EGH2050FFB | EGH3050FFB |
60 | EGH1060FFB | EGH2060FFB | EGH3060FFB |
70 | EGH1070FFB | EGH2070FFB | EGH3070FFB |
80 | EGH1080FFB | EGH2080FFB | EGH3080FFB |
90 | EGH1090FFB | EGH2090FFB | EGH3090FFB |
100 | EGH1100FFB | EGH2100FFB | EGH3100FFB |
110 | EGH1110FFB | EGH2110FFB | EGH3110FFB |
125 | EGH1125FFB | EGH2125FFB | EGH3125FFB |
Maximum Breaker
Amps |
Terminal,
Body Material |
Wire Type |
Metric Wire
Range mm (2) |
AWG Wire Range |
(Package of Three
Terminals) |
Standard Cu/Al Pressure Type Terminals | |||||
15–50 | Aluminum | Cu/Al | 2.5–50 | #14–1/0 | 3TA125EF |
60–125 | Aluminum | Cu/Al | 16–70 | #6–3/0 | 3TA150EF |
Notes:
(1) For bulk pack 24, add suffix BP24 and order quantities of 24.
(2) For bulk pack 12, add suffix BP12 and order quantities of 12.
(3) For bulk pack 8, add suffix BP8 and order quantities of 8.
3T125EF | 3TA125EF | 3TA150EF | 3TA160EFK |
EF2RTWK, Two-Pole–Metric
EF3RTWK, Three-Pole–Metric EF4RTWK, Four-Pole–Metric EF2RTDK, Two-Pole–Imperial EF3RTDK, Three-Pole–Imperial EF4RTDK, Four-Pole–Imperial |
Control Wire
Terminal Kit GCWTK |
Multiwire
Connectors |
Maximum Breaker Amps |
Terminal
Body Material |
Wire Type |
Metric Wire
Range mm2 |
AWG Wire Range | (Package of Three Terminals) Catalog Number |
Standard Cu/Al Pressure Type Terminals | |||||
125 | Steel | Al | 4-6 | #12-10 | 3T125EF (1) |
125 | Steel | Cu | 2.5-95 | #14-3/0 | 3T125EF (1) |
125 | Aluminum | Cu/Al | 2.5-50 | #14-1/0 | 3TA125EF |
160 | Aluminum | Cu/Al | 16-70 | #6-3/0 | 3TA150EF |
160 | Aluminum | Cu/Al | 35-120 | #3-250 | 3TA160EFK |
160 | Aluminum | Cu/Al | 35-120 | #3-250 | 4TA160EFK (2) |
EG-Frame circuit breakers and molded case switches have line and load terminals as standard equipment.
Insert collar enclosing conductor as shown. Locate nut on top of conductor and tighten securely with screw and washer.
Caution: Collar must surround conductor.
Insert collar enclosing conductor and center on extrusion. Tighten securely with screw and washer. Endcap kits are used on the E-Frame breaker line side to connect busbar or similar electrical connections. Includes hardware.
Notes:
(1) Standard line and load terminals.
(2) Four-pole kit with four terminals.
Part Number | |
Control wire terminal kit
Package of 12—priced individually |
5652B38G01 |
For use with steel or stainless steel standard line and load terminals only.
Part Number | |
Interphase barriers
Package of 12—priced individually |
EIPBK |
The interphase barrier is available for extended insulation between circuit breaker poles. Specify quantity when ordering.
Part Number | |
DIN rail adapter—single-pole | EF1DIN |
DIN rail adapter—two-pole | EGDIN |
DIN rail adapter—three- or four-pole | EF34DIN |
Metric base mounting hardware is included with a circuit breaker or molded case switch. (Included with breaker.) If required separately, order S/N 8703C80G08.
Note: English mounting hardware kit can be supplied separate. Catalog number is BMHE #6–32 x 3 inches for two-, three- and four-pole. Singlepole mounting hardware metric order 8703C80G11. English hardware 8703C80G12. Both sold in quantities of 100.
The terminal shield is available for line terminal areas in threeand four-pole circuit breakers. Special terminal shields are also available for use when an electrical (solenoid) operator is mounted on the circuit breaker. The standard style number by pole for each terminal shield is for a package of 10 and is priced per each package. Special terminal shields are packaged individually.
Number of Poles | Part Number |
3 | EFTS3K |
4 | EFTS4K |
The terminal end cover is available for three-pole circuit breakers only. Two conductor opening sizes are available. Specify quantity (one per circuit breaker) when ordering.
Conductor Opening Diameter
Inches (mm) |
Part Number |
6.35 (0.25) | EEC3K |
10.41 (0.41) | EEC4K |
Field-installed multiwire connectors for the load side (OFF) end terminals. They are used to distribute the load from the circuit breaker to multiple devices without the use of separate distribution terminal blocks.
Multiwire lug kits include mounting hardware, terminal shield insulators and tin-plated aluminum connectors to replace three mechanical load lugs. UL listed as used on the load side (OFF) end.
Maximum
Amperes |
Wires per
Terminal |
Wire Size
Range AWG Cu |
Part Number |
125 | 3 | 14–2 | 3TA125E3K |
125 | 6 | 14–6 | 3TA125E6K |
Notes:
(1) For four-pole kit, change “3” at beginning of catalog number to “4.”