Eaton Specialty Breaker - Accessories Guide

Eaton Molded Case Circuit Metering & Communications Modules - PM3
Molded Case Circuit Breaker Over

Eaton Specialty Breaker

Enclosures — Type 1 General Purpose

  • Surface or flush mounting
  • 15–1200 ampere range
  • 600 Vac, 500 Vdc

Type 1 enclosed breakers are designed for use in commercial buildings, apartment buildings and other areas where a general purpose enclosure is applicable. The breaker is front operable and is capable of being padlocked in either the ON or OFF position. Ratings through 1200 amperes are listed with Underwriters Laboratories as approved for service entrance application. Both surface and flush mounted enclosures are available.

Enclosures — Type 3R Rainproof Surface Mounting

  • Interchangeable hubs (through 400 amperes)
  • 15–1200 ampere range
  • 600 Vac, 500 Vdc

This general purpose outdoor service center employs a circuit breaker inside a weatherproof sheet steel breaker enclosure to serve as a main disconnect and protective device for feeder circuits. Ratings through 1200 amperes are listed by Underwriters Laboratories as suitable for service entrance application.

Enclosures — Type 12 Dustproof Surface Mounting

  • No knockouts or other openings
  • 15–1200 ampere range
  • 600 Vac, 500 Vdc

The Type 12 enclosure is designed in line with specifications for special industry applications where unusually severe conditions involving oil, coolant, dust and other foreign materials exist in the operating atmosphere. The handle padlocks in the OFF position and the cover is interlocked with the handle mechanism to prevent opening the cover with the circuit breaker in the ON position. Ratings through 1200 amperes are listed by Underwriters Laboratories as suitable for service entrance application.

Enclosure Selection Data

Breaker
Frame
Amperes
Enclosure
Type Class
Part
Number
FG
15–225
Type 1 SFDN225
Type 3R RFDN225
Type 12 JFDN225
JG
175–250
Type 1 SJDN250
Type 3R RJDN250
Type 12 JJDN250
KG
300–400
Type 1 SKDN400
Type 3R RKDN400
Type 12 JKDN400
LG
450–600
Type 1 SLDN600
Type 3R RLDN600
Type 12 JLDN600
NG
700–1200
Type 1 SNDN1200
Type 3R RNDN1200
Type 12 JNDN1200

Options and Accessories

Standard Terminals

Breaker
Frame
Max. Amp
Rating
AWG Wire
Range
Metric Wire
Range mm2
Part
Number
FG 100 14–1/0 2.5–50 3T100FB(1)
FG 150 4–4/0 25–95 3TA225FD(1)
JG 250 4–350 kcmil 25–185 TA250KB
KG 350 250–500 kcmil 120–240 TA350K
KG 400 3/0–250 kcmil (2) 95–120 3TA400K(1)
LG 600 250–500 kcmil (2) 120–240 3TA603LDK
NG 700 1–500 kcmil (2) 50–300 TA700NB1
NG 1000 3/0–400 kcmil (3) 95–185 TA1000NB1
NG 1200 4/0–500 kcmil (4) 120–300 TA1200NB1

Neutral Kits, Insulated and Groundable

Max. Enclosure
Rating (Amperes)
Main Lug Number
Size Cu/A
Ground Lug
Size Cu/Al
Part
Number
100 (1) 14–1/0 (1) 14–1/0 INK100
250 (1) 6–350 kcmil (1) 4–300 kcmil INK250
400 (1) 4–750 kcmil or
(2) 1/0–250 kcmil
(1) 4–300 kcmil INK400
600 (2) 250–500 kcmil (1) 4–300 kcmil INK600
1200 (3) 1/0 to 750 kcmil or
(4) 1/0 to 750 kcmil
(1) 6–250 kcmil INK1200
\

Internal Accessories

Auxiliary Switch(2)

Breaker
Frame
Factory
Mounted
1A-1B 2A-2B
Field Kit Factory
Mounted
Field Kit
FG(3) A06 A1X1PK A13 A2X1RPK
JG A06 A1X2PK A13 A2X2PK
KG A06 A1X3PK A13 A2X3PK
LG A06 A1X4PK A13 A2X4PK
NG A06 A1X5PK A13 A2X5PK

Shunt Trip(2)

Breaker
Frame
Rating Factory
Mounted
Field Kit
FG(3) 12–24 Vdc S02 SNT1LP03K
JG 12–24 Vdc S02 SNT2P04K
KG 12–24 Vdc S02 SNT3P04K
LG 12–24 Vdc S02 SNT4LP03K
NG 12–24 Vdc S02 SNT5LP03K

NOTES:
(1) Package of three terminals.
(2) Other accessories are available. Same as standard frame breakers.
(3) Field installation on the FG Frame is not UL listed.