Eaton E2 Mining Service Breaker Part Numbers

Eaton E2 Mining Service Breakers
Molded Case Circuit Breaker Over

E2F/E2FM

Thermal-Magnetic Circuit Breakers — Sealed Breakers with Non-Interchangeable Trip Unit — Include Line/Load Terminals

600 Vac Maximum, 250 Vdc, 25 kA at 480 Vac, Three-Pole)1)

Maximum
Ampere Rating at
40°C Number
Part Number
15 E2F3015
20 E2F3020
25 E2F3025
30 E2F3030
35 E2F3035
40 E2F3040
45 E2F3045
50 E2F305
60 E2F3060
70 E2F3070
80 E2F3080
90 E2F3090
100 E2F3100
125 E2F3125
150 E2F3150

1000Y/577 Vac Maximum, 250 Vdc, 10 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Part Number
15
20 E2FM3020
25 E2FM3025
30
35
40 E2FM3040
45
50 E2FM3050
60 E2FM3060
70 E2FM3070
80 E2FM3080
90 E2FM3090
100 E2FM3100
125 E2FM3125
150 E2FM3150

NOTES:
(1) For two-pole application, use outer poles.

600 Vac Maximum, 250 Vdc, 25 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Part Number
3 9—30 E2F003AM
7 21—70 E2F007CM
15 45—150 E2F015EM
30 90—300 E2F030HM
50—150 E2F030EM
50 150—500 E2F050KM
66—190 E2F050YM
70 210—700 E2F070MM
100 150—500 E2F100KM
300—1000 E2F100RM
150 450—1500 E2F150TM
750—2500 E2F150UM

1000Y/577 Vac Maximum, 250 Vdc, 10 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Part Number
3 9—30
7 21—70
15 45—150
30 90—300
50—150
50 150—500 E2FM050KM
66—190 E2FM050YM
70 210—700 E2FM070MM
100 150—500 E2FM100KM
300—1000 E2FM100RM
150 450—1500 E2FM150TM
750—2500 E2FM150UM

E2J/E2JM

Circuit Breakers with Interchangeable Thermal-Magnetic Trip Unit

600 Vac Maximum, 250 Vdc, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
70 300—650 E2J3070W E2J3250F E2J3070T
90 450—900 E2J3090W E2J3250F E2J3090T
100 500—1000 E2J3100W E2J3250F E2J3100T
125 625—1250 E2J3125W E2J3250F E2J3125T
150 750—1500 E2J3150W E2J3250F E2J3150T
175 875—1750 E2J3175W E2J3250F E2J3175T
200 1000—2000 E2J3200W E2J3250F E2J3200T
225 300—650 E2J3225AW E2J3250F E2J3225TA
500—1000 E2J3225DW E2J3250F E2J3225TD
1125—2250 E2J3225W E2J3250F E2J3225T
250 1250—2500 E2J3250W E2J3250F E2J3250T

1000Y/577 Vac Maximum, 250 Vdc, 10 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
70 300—650 E2JM3070W E2JM3250F E2J3070T
90 450—900 E2JM3090W E2JM3250F E2J3090T
100 500—1000 E2JM3100W E2JM3250F E2J3100T
125 625—1250 E2JM3125W E2JM3250F E2J3125T
150 750—1500 E2JM3150W E2JM3250F E2J3150T
175 875—1750 E2JM3175W E2JM3250F E2J3175T
200 1000—2000 E2JM3200W E2JM3250F E2J3200T
225 300—650 E2JM3225AW E2JM3250F E2J3225TA
500—1000 E2JM3225DW E2JM3250F E2J3225TD
1125—2250 E2JM3225W E2JM3250F E2J3225T
250 1250—2500 E2JM3250W E2JM3250F E2J3250T

600 Vac Maximum, 250 Vdc, 25 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
250 300—650 E2J3250MAW E2J3250F E2J3250TMA
450—900 E2J3250MCW E2J3250F E2J3250TMC
500—1000 E2J3250MDW E2J3250F E2J3250TMD
625—1250 E2J3250MFW E2J3250F E2J3250TMF
750—1500 E2J3250MGW E2J3250F E2J3250TMG
875—1750 E2J3250MJW E2J3250F E2J3250TMJ
1000—2000 E2J3250MKW E2J3250F E2J3250TMK
1125—2250 E2J3250MLW E2J3250F E2J3250TML
1250—2500 E2J3250MW E2J3250F E2J3250TM

1000Y/577 Vac Maximum, 250 Vdc, 10 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
250 300—650 E2JM3250MAW E2JM3250F E2J3250TMA
450—900 E2JM250MCW E2JM3250F E2J3250TMC
500—1000 E2JM3250MDW E2JM3250F E2J3250TMD
625—1250 E2JM3250MFW E2JM3250F E2J3250TMF
750—1500 E2JM3250MGW E2JM3250F E2J3250TMG
875—1750 E2JM3250MJW E2JM3250F E2J3250TMJ
1000—2000 E2JM3250MKW E2JM3250F E2J3250TMK
1125—2250 E2JM3250MLW E2JM3250F E2J3250TML
1250—2500 E2JM3250MW E2JM3250F E2J3250TM

E2K/E2KM

Circuit Breakers with Interchangeable Thermal-Magnetic Trip Unit

600 Vac Maximum, 250 Vdc, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
100 500—1000 E2K3100W E2K3400F E2K3100T
125 625—1250 E2K3125W E2K3400F E2K3125T
150 750—1500 E2K3150W E2K3400F E2K3150T
175 875—1750 E2K3175W E2K3400F E2K3175T
200 1000—2000 E2K3200W E2K3400F E2K3200T
225 300—650 E2K3225AW E2K3400F E2K3225TA
500—1000 E2K3225DW E2K3400F E2K3225TD
1125—2250 E2K3225W E2K3400F E2K3225T
250 1250—2500 E2K3250W E2K3400F E2K3250T
300 1500—3000 E2K3300W E2K3400F E2K3300T
350 1750—3500 E2K3350W E2K3400F E2K3350T
400 2000—4000 E2K3400W E2K3400F E2K3400T

1000Y/577 Vac Maximum, 250 Vdc, 14 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
100 500—1000 E2KM3100W E2KM3400F E2K3100T
125 625—1250 E2KM3125W E2KM3400F E2K3125T
150 750—1500 E2KM3150W E2KM3400F E2K3150T
175 875—1750 E2KM3175W E2KM3400F E2K3175T
200 1000—2000 E2KM3200W E2KM3400F E2K3200T
225 300—650 E2KM3225AW E2KM3400F E2K3225TA
500—1000 E2KM3225DW E2KM3400F E2K3225TD
1125—2250 E2KM3225W E2KM3400F E2K3225T
250 1250—2500 E2KM3250W E2KM3400F E2K3250T
300 1500—3000 E2KM3300W E2KM3400F E2K3300T
350 1750—3500 E2KM3350W E2KM3400F E2K3350T
400 2000—4000 E2KM3400W E2KM3400F E2K3400T

E2K/E2KM

Circuit Breakers with Interchangeable Magnetic Only Trip Unit

600 Vac Maximum, 250 Vdc, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
400 300—650 E2K3400MAW E2K3400F E2K3400TMA
500—1000 E2K3400MDW E2K3400F E2K3400TMD
625—1250 E2K3400MFW E2K3400F E2K3400TMF
750—1500 E2K3400MGW E2K3400F E2K3400TMG
875—1750 E2K3400MJW E2K3400F E2K3400TMJ
1000—2000 E2K3400MKW E2K3400F E2K3400TMK
1125—2250 E2K3400MLW E2K3400F E2K3400TML
1250—2500 E2K3400MWW E2K3400F E2K3400TMW
1500—3000 E2K3400MNW E2K3400F E2K3400TMN
1750—3500 E2K3400MRW E2K3400F E2K3400TMR
2000—4000 E2K3400MW E2K3400F E2K3400TM

1000Y/577 Vac Maximum, 250 Vdc, 14 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
400 300—650 E2KM3250MAW E2KM3400F E2K3400TMA
500—1000 E2KM3400MDW E2KM3400F E2K3400TMD
625—1250 E2KM3400MFW E2KM3400F E2K3400TMF
750—1500 E2KM3400MGW E2KM3400F E2K3400TMG
875—1750 E2KM3400MJW E2KM3400F E2K3400TMJ
1000—2000 E2KM3400MKW E2KM3400F E2K3400TMK
1125—2250 E2KM3400MLW E2KM3400F E2K3400TML
1250—2500 E2KM3400MWW E2KM3400F E2K3400TMW
1500—3000 E2KM3400MNW E2KM3400F E2K3400TMN
1750—3500 E2KM3400MRW E2KM3400F E2K3400TMR
2000—4000 E2KM3400MW E2KM3400F E2K3400TM

E2K/E2KM

Circuit Breakers with Interchangeable Electronic Trip Unit, Long/Instantaneous

600 Vac Maximum, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
100 50—800 E2KE3100W E2K3400F KEM3100T
125 50—800 E2KE3125W E2K3400F KEM3125T
150 50—800 E2KE3150W E2K3400F KEM3150T
200 200—1500 E2KE3200W E2K3400F KEM3200T
225 200—1500 E2KE3225W E2K3400F KEM3225T
500—2500 E2KE32252W E2K3400F KEM3225T2
400 200—1500 E2KE3400W E2K3400F KEM3400T
500—2500 E2KE34002W E2K3400F KEM3400T2

1000Y/577 Vac Maximum, 14 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
100 50—800 E2KEM3100W E2KM3400F KEM3100T
125 50—800 E2KEM3125W E2KM3400F KEM3125T
150 50—800 E2KEM3150W E2KM3400F KEM3150T
200 200—1500 E2KEM3200W E2KM3400F KEM3200T
225 200—1500 E2KEM3225 E2KM3400F KEM3225T
500—2500 E2KEM32252W E2KM3400F KEM3225T2
400 200—1500 E2KEM3400W E2KM3400F KEM3400T
500—2500 E2KEM34002W E2KM3400F KEM3400T2

E2K/E2KM

Circuit Breakers with Interchangeable Electronic Trip Unit, Instantaneous Only

600 Vac Maximum, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
150 50—800 E2KE3150MW E2K3400F KEM3150TM
225 200—1500 E2KE3225MW E2K3400F KEM3225TM
500—2500 E2KE3225M2W E2K3400F KEM3225TM2
400 200—1500 E2KE3400MW E2K3400F KEM3400TM
500—2500 E2KE3400M2W E2K3400F KEM3400TM2

1000Y/577 Vac Maximum, 14 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
150 50—800 E2KEM3150MW E2KM3400F KEM3150TM
225 200—1500 E2KEM3225MW E2KM3400F KEM3225TM
500—2500 E2KEM3225M2W E2KM3400F KEM3225TM2
400 200—1500 E2KEM3400MW E2KM3400F KEM3400TM
500—2500 E2KEM3400M2W E2KM3400F KEM3400TM2

E2LME/E2LMZ (Series G)

Circuit Breakers with Magnetic Only Trip Unit

600 Vac Maximum, 250 Vdc, 65 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
400 3600—4400 E2LME3400KMW E2LME3400NN LT3400KM

1000Y/577 Vac Maximum, 250 Vdc, 10 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
400 3600—4400 E2LMZ3400KMW E2LMZ3400NN LT3400KM

Circuit Breakers with Interchangeable Electronic Trip Unit

600 Vac Maximum, 65 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
160 320—1920 E2LME340031W E2LME3400NN LT340031M
200 400—2400 E2LME340031W E2LME3400NN LT340031M
225 450—2700 E2LME340031W E2LME3400NN LT340031M
250 500—3000 E2LME340031W E2LME3400NN LT340031M
300 600—3600 E2LME340031W E2LME3400NN LT340031M
315 630—3780 E2LME340031W E2LME3400NN LT340031M
350 700—4200 E2LME340031W E2LME3400NN LT340031M
400 800—4800 E2LME340031W E2LME3400NN LT340031M

1000Y/577 Vac Maximum, 10 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
160 320—1920 E2LMZ340031W E2LMZ3400NN LT340031M
200 400—2400 E2LMZ340031W E2LMZ3400NN LT340031M
225 450—2700 E2LMZ340031W E2LMZ3400NN LT340031M
250 500—3000 E2LMZ340031W E2LMZ3400NN LT340031M
300 600—3600 E2LMZ340031W E2LMZ3400NN LT340031M
315 630—3780 E2LMZ340031W E2LMZ3400NN LT340031M
350 700—4200 E2LMZ340031W E2LMZ3400NN LT340031M
400 800—4800 E2LMZ340031W E2LMZ3400NN LT340031M

E2L/E2LM

Circuit Breakers with Interchangeable Thermal-Magnetic Trip Unit

600 Vac Maximum, 250 Vdc, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
300 1500—3000 E2L3300W E2L3600F E2L3300T
350 1750—3500 E2L3350W E2L3600F E2L3350T
400 2000—4000 E2L3400W E2L3600F E2L3400T
450 2250—4500 E2L3450W E2L3600F E2L3450T
500 2500—5000 E2L3500W E2L3600F E2L3500T
600 3000—6000 E2L3600W E2L3600F E2L3600T

1000Y/577 Vac Maximum, 250 Vdc, 18 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
300 1500—3000 E2LM3300W E2LM3600F E2L3300T
350 1750—3500 E2LM3350W E2LM3600F E2L3350T
400 2000—4000 E2LM3400W E2LM3600F E2L3400T
450 2250—4500 E2LM3450W E2LM3600F E2L3450T
500 2500—5000 E2LM3500W E2LM3600F E2L3500T
600 3000—6000 E2LM3600W E2LM3600F E2L3600T
1125—2250 E2LM3600F E2L3600TL(1)

NOTE:
(1) 600 ampere thermal 1125–2250 T.A.

E2L/E2LM

Circuit Breakers with Interchangeable Magnetic Only Trip Unit

600 Vac Maximum, 250 Vdc, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
600 1125—2250 E2L3600MLW E2L3600F E2L3600TML
1500—3000 E2L3600MNW E2L3600F E2L3600TMN
1750—3500 E2L3600MRW E2L3600F E2L3600TMR
2000—4000 E2L3600MXW E2L3600F E2L3600TMX
2250—4500 E2L3600MYW E2L3600F E2L3600TMY
2500—5000 E2L3600MPW E2L3600F E2L3600TMP
3000—6000 E2L3600MW E2L3600F E2L3600TM

1000Y/577 Vac Maximum, 250 Vdc, 18 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
600 1125—2250 E2LM3600MLW E2LM3600F E2L3600TML
1500—3000 E2LM3600MNW E2LM3600F E2L3600TMN
1750—3500 E2LM3600MRW E2LM3600F E2L3600TMR
2000—4000 E2LM3600MXW E2LM3600F E2L3600TMX
2250—4500 E2LM3600MYW E2LM3600F E2L3600TMY
2500—5000 E2LM3600MPW E2LM3600F E2L3600TMP
3000—6000 E2LM3600MW E2LM3600F E2L3600TM

E2L/E2LM

Circuit Breakers with Interchangeable Electronic Trip Unit, Long/Instantaneous

600 Vac Maximum, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
300 500—2500 E2LE3300W E2L3600F LEM3300T
350 500—2500 E2LE3350W E2L3600F LEM3350T
400 500—2500 E2LE3400W E2L3600F LEM3400T
1000—4000 E2LE34002W E2L3600F LEM3400T2
600 500—2500 E2LE3600W E2L3600F LEM3600T
2500—5000 E2LE36002W E2L3600F LEM3600T2

1000Y/577 Vac Maximum, 18 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
300 500—2500 E2LEM3300W E2LM3600F LEM3300T
350 500—2500 E2LEM3350W E2LM3600F LEM3350T
400 500—2500 E2LEM3400W E2LM3600F LEM3400T
1000—4000 E2LEM34002W E2LM3600F LEM3400T2
600 500—2500 E2LEM3600W E2LM3600F LEM3600T
2500—5000 E2LEM36002W E2LM3600F LEM3600T2

Circuit Breakers with Interchangeable Electronic Trip Unit, Instantaneous Only

600 Vac Maximum, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
400 500-2500 E2LE3400MW E2L3600F LEM3400TM
1000-4000 E2LE3400M2W E2L3600F LEM3400TM2
600 500-2500 E2LE3600MW E2L3600F LEM3600TM
2500-5000 E2LE3600M2W E2L3600F LEM3600TM2

1000Y/577 Vac Maximum, 18 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
400 500-2500 E2LEM3400MW E2LM3600F LEM3400TM
1000-4000 E2LEM3400M2W E2LM3600F LEM3400TM2
600 500-2500 E2LEM3600MW E2LM3600F LEM3600TM
2500-5000 E2LEM3600M2W E2LM3600F LEM3600TM2

E2M/E2MM

Circuit Breaker with Interchangeable Thermal-Magnetic Trip Unit

600 Vac Maximum, 250 Vdc, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
600 1500—3000 E2M3600W E2M3800F E2M3600TN
800 2000—4000 E2M3800W E2M3800F E2M3800TX

1000Y/577 Vac Maximum, 250 Vdc, 18 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
600 1500—3000 E2MM3600W E2MM3800F E2M3600TN
800 2000—4000 E2MM3800W E2MM3800F E2M3800TX

Circuit Breaker with Interchangeable Magnetic Only Trip Unit

600 Vac Maximum, 250 Vdc, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
800 1500–3000 E2M3800MNW E2M3800F E2M3800TMN
2000–4000 E2M3800MXW E2M3800F E2M3800TMX
2500–5000 E2M3800MPW E2M3800F E2M3800TMP
3000–6000 E2M3800MWW E2M3800F E2M3800TMW

1000Y/577 Vac Maximum, 250 Vdc, 18 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
800 1500–3000 E2MM3800MNW E2MM3800F E2M3800TMN
2000–4000 E2MM3800MXW E2MM3800F E2M3800TMX
2500–5000 E2MM3800MPW E2MM3800F E2M3800TMP
3000–6000 E2MM3800MWW E2MM3800F E2M3800TMW

E2M/E2MM

Circuit Breaker with Interchangeable Electronic Trip Unit, Long/Instantaneous

600 Vac Maximum, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
800 500—2500 E2ME3800W E2M3800F MEM3800T
1000—4000 E2ME38002W E2M3800F MEM3800T2

1000Y/577 Vac Maximum, 18 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
800 500—2500 E2MEM3800W E2MM3800F MEM3800T
1000—4000 E2MEM38002W E2MM3800F MEM3800T2

Circuit Breaker with Interchangeable Electronic Trip Unit, Instantaneous Only

600 Vac Maximum, 35 kA at 480 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
800 500—2500 E2ME3800MW E2M3800F MEM3800TM
1000—4000 E2ME3800M2W E2M3800F MEM3800TM2

1000Y/577 Vac Maximum, 18 kA at 1000 Vac, Three-Pole

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Complete Breaker Frame Only
Trip Unit Only
800 500—2500 E2MEM3800MW E2MM3800F MEM3800TM
1000—4000 E2MEM3800M2W E2MM3800F MEM3800TM2

E2N/E2NM

Circuit Breakers with Electronic Trip Unit, Long/Instantaneous

600 Vac Maximum, 50 kA at 480 Vac, Three-Pole Frame

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Part Number
400 500—2500 E2N3400W
500 500—2500 E2N3500W
600 500—2500 E2N3600W
700 500—2500 E2N3700W
800 500—2500 E2N3800W
900 1250—5000 E2N3900W
1000 1250—5000 E2N310W
1200 1250—5000 E2N312W

1000Y/577 Vac Maximum, 25 kA at 1000 Vac, Three-Pole Frame

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Part Number
400 500—2500 E2NM3400W
500 500—2500 E2NM3500W
600 500—2500 E2NM3600W
700 500—2500 E2NM3700W
800 500—2500 E2NM3800W
900 1250—5000 E2NM3900W
1000 1250—5000 E2NM310W
1200 1250—5000 E2NM312W

Circuit Breakers with Electronic Trip Unit, Instantaneous Only

600 Vac Maximum, 50 kA at 480 Vac, Three-Pole Frame

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Part Number
800 500—2500 E2N3800MW
1200 1250—5000 E2N312MW

1000Y/577 Vac Maximum, 25 kA at 1000 Vac, Three-Pole Frame

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Part Number
800 500—2500 E2NM3800MW
1200 1250—5000 E2NM312MW

E2R/E2RM

Circuit Breakers with Electronic Trip Unit, Long/Instantaneous (Does Not Include Rating Plugs)(1)

600 Vac Maximum, 50 kA at 480 Vac, Three-Pole Frame

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Part Number
LS
1600 2—8 x ln E2R316T33W
2000 2—8 x ln E2R320T33W
LSI
1600 2—8 x ln E2R316T32W
2000 2—8 x ln E2R320T32W

600 Vac Maximum, 50 kA at 480 Vac, Three-Pole Frame

Maximum
Ampere Rating at
40°C Number
Magnetic
Trip Range
Part Number
LS
1600 2—8 x ln E2RM316T33W
2000 2—8 x ln E2RM320T33W
LSI
1600 2—8 x ln E2RM316T32W
2000 2—8 x ln E2RM320T32W

NOTES:
(1) Rating plugs: 1600 amperes 16RES16T; 2000 amperes 20RES20T.

Let our expert sales staff guide you through finding the right products to fit your needs. CALL 866-595-9616.