EATON Molded Case Circuit Breakers Series-G, Frame Size - LG
Series-G, Frame Size-LG
Complete Breaker (Includes Frame, Trip Unit, Standard Terminals and Mounting Hardware)
LG-Frame—630 Amperes (600 Amperes UL, CSA) IC Rating: 35 kAIC at 415 and 480 Vac(1)
Ampere Rating | Three-Pole(2) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
Four-Pole (0%)(3) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
250 | LGE3250FAG | LGE3250AAG | LGE4250FAG | LGE4250AAG |
300 | LGE3300FAG | — | LGE4300FAG | — |
320 | — | LGE3320AAG | — | LGE4320AAG |
350 | LGE3350FAG | — | LGE4350FAG | — |
400 | LGE3400FAG | LGE3400AAG | LGE4400FAG | LGE4400AAG |
500 | LGE3500FAG | LGE3500AAG | LGE4500FAG | LGE4500AAG |
600 | LGE3600FAG | — | LGE4600FAG | — |
6304 | — | LGE3630AAG | — | LGE4630AAG |
LG-Frame—630 Amperes (600 Amperes UL, CSA) IC Rating: 50 kAIC at 415 and 480 Vac(1)
Ampere Rating | Three-Pole(2) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
Four-Pole (0%)(3) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
250 | LGS3250FAG | LGS3250AAG | LGS4250FAG | LGS4250AAG |
300 | LGS3300FAG | — | LGS4300FAG | |
320 | LGS3320AAG | — | LGS4320AAG | |
350 | LGS3350FAG | — | LGS4350FAG | — |
400 | LGS3400FAG | LGS3400AAG | LGS4400FAG | LGS4400AAG |
500 | LGS3500FAG | LGS3500AAG | LGS4500FAG | LGS4500AAG |
600 | LGS3600FAG | — | LGS4600FAG | — |
630(4) | — | LGS3630AAG | — | LGS4630AAG |
LG-Frame—630 Amperes (600 Amperes UL, CSA) IC Rating: 70 kAIC at 415, 65 kAIC at 480 Vac(1)
Ampere Rating | Three-Pole(2) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
Four-Pole (0%)(3) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
250 | LGH3250FAG | LGH3250AAG | LGH4250FAG | LGH4250AAG |
300 | LGH3300FAG | — | LGH4300FAG | — |
320 | LGH3320AAG | LGH4320AAG | ||
350 | LGH3350FAG | — | LGH4350FAG | — |
400 | LGH3400FAG | LGH3400AAG | LGH4400FAG | LGH4400AAG |
500 | LGH3500FAG | LGH3500AAG | LGH4500FAG | LGH4500AAG |
600 | LGH3600FAG | — | LGH4600FAG | — |
630(4) | — | LGH3630AAG | — | LGH4630AAG |
LG-Frame—630 Amperes (600 Amperes UL, CSA), Current Limiting Per UL 489IC Rating:
100 kAIC at 415 and 480 Vac(1)
Ampere Rating | Three-Pole(2) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
Four-Pole (0%)(3) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
250 | LGC3250FAG | LGC3250AAG | LGC4250FAG | LGC4250AAG |
300 | LGC3300FAG | - | LGC4300FAG | - |
320 | - | LGC3320AAG | - | LGC4320AAG |
350 | LGC3350FAG | - | LGC4350FAG | - |
400 | LGC3400FAG | LGC3400AAG | LGC4400FAG | LGC4400AAG |
500 | LGC3500FAG | LGC3500AAG | LGC4500FAG | LGC4500AAG |
600 | LGC3600FAG | - | LGC4600FAG | - |
630(4) | - | LGC3630AAG | - | LGC4630AAG |
LG-Frame—630 Amperes (600 Amperes UL, CSA), Current Limiting Per UL 489 IC Rating:
150 kAIC at 415 and 480 Vac(1)
Ampere Rating | Three-Pole(2) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
Four-Pole (0%)(3) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
250 | LGU3250FAG | LGU3250AAG | LGU4250FAG | LGU4250AAG |
300 | LGU3300FAG | - | LGU4300FAG | - |
320 | - | LGU3320AAG | - | LGU4320AAG |
350 | LGU3350FAG | - | LGU4350FAG | - |
400 | LGU3400FAG | LGU3400AAG | LGU4400FAG | LGU4400AAG |
500 | LGU3500FAG | LGU3500AAG | LGU4500FAG | LGU4500AAG |
600 | LGU3600FAG | - | LGU4600FAG | - |
630(4) | - | LGU3630AAG | - | LGU4630AAG |
LG-Frame—630 Amperes (600 Amperes UL, CSA), Current Limiting Per UL 489 IC Rating: 200 kAIC at 415 and 480 Vac(1)
Ampere Rating | Three-Pole(2) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
Four-Pole (0%)(3) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4)(5) |
250 | LGX3250FAG | LGX3250AAG | LGX4250FAG | LGX4250AAG |
300 | LGX3300FAG | - | LGX4300FAG | - |
320 | - | LGX3320AAG | - | LGX4320AAG |
350 | LGX3350FAG | - | LGX4350FAG | - |
400 | LGX3400FAG | LGX3400AAG | LGX4400FAG | LGX4400AAG |
500 | LGX3500FAG | LGX3500AAG | LGX4500FAG | LGX4500AAG |
600 | LGX3600FAG | - | LGX4600FAG | - |
630(4) | - | LGX3630AAG | - | LGX4630AAG |
Notes:
(1) Replace suffix “G” with “W” for no line and load terminals.
(2) For two-pole applications, use two outer poles.
(3) Neutral protection is indicated by the fourth character: 4 = 0%, 7 = 100%, 8 = adjustable 0–60% and 9 = 0–100%. Neutral is on LH side.
(4) 320/630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA rating for the LG.
(5) Adjustable thermal units are typically used in IEC markets and are not UL or CSA listed.
Molded Case Switches(1)
Ampere Rating | Number of Poles | Part Number |
400 | 3(2) | LGK3400KSG |
4 | LGK4400KSG | |
630(3) | 3(2) | LGK3630KSG |
4 | LGK4630KSG |
Frame—IC Rating at 415/480 Volts
Maximum Amperes(3) | Three-Pole(2) Part Number | Four-Pole 0% Part Number |
35/35 | ||
630(3) | LGE3630NN | LGE4630NN |
LGE3630NNWC | - | |
50/50 | ||
630(3) | LGS3630NN | LGS4630NN |
LGS3630NNWC | - | |
70/53 | ||
630(3) | LGH3630NN | LGH4630NN |
LGH3630NNWC | - | |
100/100 Current Limiting Per UL 489 | ||
630 | LGC3630NN | LGC4630NN |
150/150 Current Limiting Per UL 489 | ||
630 | LGU3630NN | LGU4630NN |
200/200 Current Limiting | ||
630 | LGX3630NN | LGX4630NN |
Thermal-Magnetic Trip Unit
Ampere Rating |
Three-Pole(2) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4) |
Four-Pole (0%)(5) Fixed Thermal, Adjustable Magnetic |
Adjustable Thermal, Adjustable Magnetic(4) |
250 | LT3250FA | LT3250AA | LT4250FA | LT4250AA |
300 | LT3300FA | - | LT4300FA | - |
320 | - | LT3320AA | - | LT4320AA |
350 | LT3350FA | - | LT4350FA | - |
400 | LT3400FA | LT3400AA | LT4400FA | LT4400AA |
500 | LT3500FA | LT3500AA | LT4500FA | LT4500AA |
600 | LT3600FA | - | LT4600FA | - |
630 | - | LT3630AA | - | LT4630AA |
Notes:
(1) Molded case switches will trip above 6300 amperes.
(2) For two-pole applications, use two outer poles.
(3) 630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA rating for the LG.
(4) Adjustable thermal, adjustable magnetic trip units are typically used in IEC markets and are not UL or CSA listed.
(5) Neutral protection is indicated by the third character: 4 = 0%, 7 = 100%, 8 = adjustable 0–60% and 9 = 0–100%.
(6) 100% rated frame.
Electronic Trip Units-Digitrip 310+
Ampere Rating |
LS |
LSI |
LSG |
LSIG |
Neutral CT for LSG and LSIG(1) |
Three-Pole | |||||
250 | LT325033 | LT325032 | LT325035 | LT325036 | LGFCT250 |
400 | LT340033 | LT340032 | LT340035 | LT340036 | LGFCT400 |
600 | LT360033 | LT360032 | LT360035 | LT360036 | LGFCT600 |
630(2) | LT363033 | LT363032 | LT363035 | LT360036 | LGFCT630 |
Four-Pole(3) | |||||
250 | LT425033 | LT425032 | LT425035 | LT425036 | - |
400 | LT440033 | LT440032 | LT440035 | LT440036 | - |
600 | LT460033 | LT460032 | LT460035 | LT460036 | - |
630(2) | LT463033 | LT463032 | LT463035 | LT463036 | - |
Plug-In Test Kit(4)
Voltage Ratimng | Part Number |
120 Vac | MTST120V |
230 Vac | MTST230V |
Notes:
(1) Required for four-wire systems if neutral protection is desired.
(2) 630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA listed rating for the LG.
(3) Neutral protection: 4= 0%, 6 = 60%, 7 = 100%. Electronic trip unit neutral protection is not adjustable.
(4) IL Number is 5721B13.
Long time pickup — selectable via dial setting.
630 ampere settings — 630, 600, 500, 400, 350, 315, 300, 250 (315, 630 are IEC ratings only).
600 ampere settings — 600, 500, 450, 400, 350, 315, 300, 250 (315 is IEC rating only).
400 ampere settings — 400, 350, 315, 300, 250, 225, 200, 160 (315 is IEC rating only).
250 ampere settings — 250, 225, 200, 175, 160, 150, 125, 100 (160 is IEC rating only).
Adjustable long time delay — 2–24 seconds at 6 x Ir.
Adjustable short time delay — Inst., 120, 300 ms.
IC Rating at 415/480V Complete LG Breakers with Electronic Trip Unit (Includes Frame, Trip Unit, Standard Terminals and Mounting Hardware)(1)
IC Rating: 35 kAIC at 415 and 480 Vac
Ampere Rating |
LS |
LSI |
LSG |
LSIG |
Neutral CT for LSG and LSIG(2) |
Three-Pole(3) | |||||
250 | LGE325033G | LGE325032G | LGE325035G | LGE325036G | LGFCT250 |
400 | LGE340033G | LGE340032G | LGE340035G | LGE340036G | LGFCT400 |
600 | LGE360033G | LGE360032G | LGE360035G | LGE360036G | LGFCT600 |
630(4) | LGE363033G | LGE363032G | LGE363035G | LGE363036G | LGFCT630 |
Four-Pole(5) | |||||
250 | LGE425033G | LGE425032G | LGE425035G | LGE425036G | - |
400 | LGE440033G | LGE440032G | LGE440035G | LGE440036G | - |
600 | LGE460033G | LGE460032G | LGE460035G | LGE460036G | - |
630(4) | LGE463033G | LGE463032G | LGE463035G | LGE463036G | - |
IC Rating: 50 kAIC at 415 and 480 Vac
Ampere Rating |
LS |
LSI |
LSG |
LSIG |
Neutral CT for LSG and LSIG(2) |
Three-Pole(3) | |||||
250 | LGS325033G | LGS325032G | LGS325035G | LGS325036G | LGFCT250 |
400 | LGS340033G | LGS340032G | LGS340035G | LGS340036G | LGFCT400 |
600 | LGS360033G | LGS360032G | LGS360035G | LGS360036G | LGFCT600 |
630(4) | LGS363033G | LGS363032G | LGS363035G | LGS363036G | LGFCT630 |
Four-Pole(5) | |||||
250 | LGS425033G | LGS425032G | LGS425035G | LGS425036G | - |
400 | LGS440033G | LGS440032G | LGS440035G | LGS440036G | - |
600 | LGS460033G | LGS460032G | LGS460035G | LGS460036G | - |
630(4) | LGS463033G | LGS463032G | LGS463035G | LGS463036G | - |
IC Rating: 70 kAIC at 415 Vac, 65 kAIC at 480 Vac
Ampere Rating |
LS |
LSI |
LSG |
LSIG |
Neutral CT for LSG and LSIG(2) |
Three-Pole(3) | |||||
250 | LGH325033G | LGH325032G | LGH325035G | LGH325036G | LGFCT250 |
400 | LGH340033G | LGH340032G | LGH340035G | LGH340036G | LGFCT400 |
600 | LGH360033G | LGH360032G | LGH360035G | LGH360036G | LGFCT600 |
630(4) | LGH363033G | LGH363032G | LGH363035G | LGH363036G | LGFCT630 |
Four-Pole(5) | |||||
250 | LGH425033G | LGH425032G | LGH425035G | LGH425036G | - |
400 | LGH440033G | LGH440032G | LGH440035G | LGH440036G | - |
600 | LGH460033G | LGH460032G | LGH460035G | LGH460036G | - |
630(4) | LGH463033G | LGH463032G | LGH463035G | LGH463036G | - |
IC Rating: 100 kAIC at 415 Vac and 480 Vac, Current Limiting Per UL 489
Ampere Rating |
LS |
LSI |
LSG |
LSIG |
Neutral CT for LSG and LSIG(2) |
Three-Pole(3) | |||||
250 | LGC325033G | LGC325032G | LGC325035G | LGC325036G | LGFCT250 |
400 | LGC340033G | LGC340032G | LGC340035G | LGC340036G | LGFCT400 |
600 | LGC360033G | LGC360032G | LGC360035G | LGC360036G | LGFCT600 |
630(4) | LGC363033G | LGC363032G | LGC363035G | LGC363036G | LGFCT630 |
Four-Pole(5) | |||||
250 | LGC425033G | LGC425032G | LGC425035G | LGC425036G | - |
400 | LGC440033G | LGC440032G | LGC440035G | LGC440036G | - |
600 | LGC460033G | LGC460032G | LGC460035G | LGC460036G | - |
630(4) | LGC463033G | LGC463032G | LGC463035G | LGC463036G | - |
IC Rating: 150 kAIC at 415 Vac and 480 Vac, Current Limiting Per UL 489
Ampere Rating |
LS |
LSI |
LSG |
LSIG |
Neutral CT for LSG and LSIG(2) |
Three-Pole(3) | |||||
250 | LGU325033G | LGU325032G | LGU325035G | LGU325036G | LGFCT250 |
400 | LGU340033G | LGU340032G | LGU340035G | LGU340036G | LGFCT400 |
600 | LGU360033G | LGU360032G | LGU360035G | LGU360036G | LGFCT600 |
630(4) | LGU363033G | LGU363032G | LGU363035G | LGU363036G | LGFCT630 |
Four-Pole(5) | |||||
250 | LGU425033G | LGU425032G | LGU425035G | LGU425036G | - |
400 | LGU440033G | LGU440032G | LGU440035G | LGU440036G | - |
600 | LGU460033G | LGU460032G | LGU460035G | LGU460036G | - |
630(4) | LGU463033G | LGU463032G | LGU463035G | LGU463036G | - |
IC Rating: 200 kAIC at 415 Vac and 480 Vac, Current Limiting Per UL 489
Ampere Rating |
LS |
LSI |
LSG |
LSIG |
Neutral CT for LSG and LSIG(2) |
Three-Pole(3) | |||||
250 | LGX325033G | LGX325032G | LGX325035G | LGX325036G | LGFCT250 |
400 | LGX340033G | LGX340032G | LGX340035G | LGX340036G | LGFCT400 |
600 | LGX360033G | LGX360032G | LGX360035G | LGX360036G | LGFCT600 |
630(4) | LGX363033G | LGX363032G | LGX363035G | LGX363036G | |
Four-Pole(5) | |||||
250 | LGX425033G | LGX425032G | LGX425035G | LGX425036G | - |
400 | LGX440033G | LGX440032G | LGX440035G | LGX440036G | - |
600 | LGX460033G | LGX460032G | LGX460035G | LGX460036G | - |
630(4) | LGX463033G | LGX463032G | LGX463035G | LGX463036G | - |
Notes:
(1) Replace suffix “G” with “W” for no line and load terminals.
(2) Required for four-wire systems if neutral protection is desired.
(3) For two-pole applications, use two outer poles.
(4) 630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA listed rating for the LG.
(5) Neutral protection: 4= 0%, 6 = 60%, 7 = 100%. Electronic trip unit neutral protection is not adjustable.
LG 100% Rated Circuit Breaker—Thermal-Magnetic Trip Unit Complete Breaker (Includes Frame, Trip Unit, Standard Terminals and Mounting Hardware)
LG-Frame—630 Amperes (600 Amperes UL, CSA) IC Rating: 35 kAIC at 415 and 480 Vac(1)
Ampere Rating | Three-Pole(2) Fixed Thermal, Adjustable Magnetic |
250 | LGE3250FAGC |
300 | LGE3300FAGC |
320 | - |
350 | LGE3350FAGC |
400 | LGE3400FAGC |
500 | LGE3500FAGC |
600 | LGE3600FAGC |
600(4) | - |
LG-Frame—630 Amperes (600 Amperes UL, CSA) IC Rating: 50 kAIC at 415 and 480 Vac(1)
Ampere Rating | Three-Pole(2) Fixed Thermal, Adjustable Magnetic |
250 | LGS3250FAGC |
300 | LGS3300FAGC |
320 | - |
350 | LGS3350FAGC |
400 | LGS3400FAGC |
500 | LGS3500FAGC |
600 | LGS3600FAGC |
600(4) | - |
LG-Frame—630 Amperes (600 Amperes UL, CSA) IC Rating: 70 kAIC at 415, 65 kAIC at 480 Vac(1)
Ampere Rating | Three-Pole(2) Fixed Thermal, Adjustable Magnetic |
250 | LGH3250FAGC |
300 | LGH3300FAGC |
320 | - |
350 | LGH3350FAGC |
400 | LGH3400FAGC |
500 | LGH3500FAGC |
600 | LGH3600FAGC |
600(4) | - |
Notes:
(1) Replace suffix “G” with “W” for no line and load terminals.
(2) For two-pole applications, use two outer poles.
LG 100% Rated Electronic Breaker Per UL 489
IEC/UL/CSA 35 kAIC at 415 and 480 Vac
Ampere Rating | LS | LSI | LSG | LSIG | Neutral CT for LSG and LSIG(1) |
250 | LGE325033GC | LGE325032GC | LGE325035GC | LGE325036GC | LGFCT250 |
400 | LGE340033GC | LGE340032GC | LGE340035GC | LGE340036GC | LGFCT400 |
600 | LGE360033GC | LGE360032GC | LGE360035GC | LGE360036GC | LGFCT600 |
630(2) | LGE363033GC | LGE363032GC | LGE363035GC | LGE363036GC | LGFCT630 |
IEC/UL/CSA 50 kAIC at 415 and 480 Vac
Ampere Rating | LS | LSI | LSG | LSIG | Neutral CT for LSG and LSIG(1) |
250 | LGS325033GC | LGS325032GC | LGS325035GC | LGS325036GC | LGFCT250 |
400 | LGS340033GC | LGS340032GC | LGS340035GC | LGS340036GC | LGFCT400 |
600 | LGS360033GC | LGS360032GC | LGS360035GC | LGS360036GC | LGFCT600 |
630(2) | LGS363033GC | LGS363032GC | LGS363035GC | LGS363036GC | LGFCT630 |
IEC/UL/CSA 70 kAIC at 415 and 480 Vac
Ampere Rating | LS | LSI | LSG | LSIG | Neutral CT for LSG and LSIG(1) |
250 | LGH325033GC | LGH325032GC | LGH325035GC | LGH325036GC | LGFCT250 |
400 | LGH340033GC | LGH340032GC | LGH340035GC | LGH340036GC | LGFCT400 |
600 | LGH360033GC | LGH360032GC | LGH360035GC | LGH360036GC | LGFCT600 |
630(2) | LGH363033GC | LGH363032GC | LGH363035GC | LGH363036GC | LGFCT630 |
Notes:
(1) Required for four-wire systems if neutral protection is required.
(2) 630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA listed rating for the LG.
LG Electronic Breaker with Arcflash Reduction Maintenance System
Series G LG circuit breakers are available with the Arcflash Reduction Maintenance System™ integrated into the electronic trip units helping to improve safety by providing a simple and reliable method to reduce fault clearing time. The Arcflash Reduction Maintenance System unit utilizes a separate analog trip circuit that provides faster
interruption times than the standard (digital) “instantaneous” protection. Work locations downstream of a circuit breaker with an Arcflash Reduction Maintenance System unit can have a significantly lower incident energy level, reducing arc flash potential to the system.
LG Electronic Breaker with Arcflash Reduction Maintenance System
LG Electronic Trip Units with Arcflash Reduction Maintenance System
Ampere Rating | ALSI |
ALSIG |
Neutral CT for LSG and LSIG(1) |
250 | LT325038 | LT325039 | LGFCT250 |
400 | LT340038 | LT340039 | LGFCT400 |
600 | LT360038 | LT360039 | LGFCT600 |
630 | LT363038 | LT363039 | LGFCT630 |
Notes:
(1) Required for four-wire systems if neutral protection is required.
Accessories Selection Guide and Ordering Information
Line and Load Terminals
Maximum Breaker Amperes |
Terminal Body Material |
Wire Type |
AWG Wire Range/ Number of Conductors |
Metric Wire Range (mm2) |
Number of Terminals Included |
Part Number |
400 | Aluminum | Cu/Al | 500-750 (1) | 240-380 (1) | 3 | 3TA631LK(1) |
400 | Aluminum | Cu/Al | 500-750 (1) | 240-380 (1) | 4 | 4TA631LK(1) |
400 | Copper | Cu | 500-750 (1) | 240-380 (1) | 3 | 3T631LK(1) |
400 | Copper | Cu | 500-750 (1) | 240-380 (1) | 4 | 4T631LK(1) |
630 | Aluminum | Cu/Al | 2-500 (2) | 35-240 (2) | 1 | TA632L |
630 | Aluminum | Cu/Al | 2-500 (2) | 35-240 (2) | 3 | 3TA632LK(1)(2) |
630 | Aluminum | Cu/Al | 2-500 (2) | 35-240 (2) | 4 | 4TA632LK(1)(2) |
630 | Copper | Cu | 2-500 (2) | 35-240 (2) | 3 | 3T632LK(1) |
630 | Copper | Cu | 2-500 (2) | 35-240 (2) | 4 | 4T632LK(1) |
400 | Aluminum | Cu/Al | 3-500 (1) | 35-240 (1) | 1 | TA350LK(2) |
400 | Copper | Cu | 3-500 (1) | 35-240 (1) | 1 | T350LK |
Base Mounting Hardware
Base mounting hardware is included with a circuit breaker or molded case switch. (Included with breaker.) If required separately, order 66A4560G03.Terminal Covers
Description | Part Number |
Three-pole terminal cover(3) | LTS3K |
Four-pole terminal cover(3) | LTS4K |
Control Wire Terminal Kit
Description | Terminal Body Type |
Part Number |
Three-pole kit | Aluminum | 3TA632LKW |
Four-pole kit | Aluminum | 4TA632LKW |
Three-pole kit | Copper | 3T632LKW |
Four-pole kit | Copper | 4T632LKW |
Terminal Spreaders
Number of Poles | Part Number |
3 | LGTEW3 |
4 | LGTEW4 |
Terminal Extensions
Number of Poles | Part Number |
3 | LGTES3 |
4 | LGTES4 |
Handle Extension
Description | Part Number |
Handle extension | HEXLG |
Interphase Barrier
Package of 2 | Part Number |
Interphase barrier | IPB3 |
Rear Fed Terminals
Maximum Amperes | Wire Size Range AWG Cu |
Part Number |
400 | 2–500 kcmil | TA350LKRF |
400 | 2–500 kcmil | 3TA350LKRF |
630 | 2–500 (2) kcmil | TA632LKRF |
630 | 2–500 (2) kcmil | 3TA632LKRF |
Rear fed terminals allow the cable to connect to the breaker from the back instead of the top. Terminal shields or interphase barriers are included with each rear fed terminal kit (depending on frame size). When catalog number starts with a 3, it indicates a kit with three terminals in each kit. Catalog number beginning with a TA indicates one terminal.
Multiwire Connectors
Field-installed multiwire connectors for the load side (OFF) end terminals are used to distribute the load from the circuit breaker to multiple devices without the use of separate distribution terminal blocks.
Multiwire lug kits include terminal shield, mounting hardware, insulators and tin-plated aluminum connectors to replace three mechanical load lugs. UL listed as used on the load side (OFF) end.
LG-Frame Multiwire Connectors Ordering Information (Package of 3)
Maximum Amperes |
Wires per Terminal |
Wire Size Range AWG Cu |
Kit Part Number |
600 | 6 | 14–1/0 | 3TA600L6K |
Notes:
(1) Includes LTS3K (three-pole) or LTS4K (four-pole) terminal covers.
(2) Standard terminal included with complete breaker.
(3) Included in TA63IL, T63IL, TA632L kits listed above.