We Have
Eaton/Moeller
Programmable Relays
Call Now! (866) 595-9616

We are experts in Electrical Motor Controls & Machine Automation Parts. As an Authorized Eaton/Moeller Distributor we specialize in helping our customers with upgrading or replacing damaged parts.
We are experts. Call us today!

Eaton Moeller Programmable Relay Family Shot

Experts in Part Replacement - Same Day Shipping 
1-866-595-9616

Eaton/Moeller Programmable Relays

The easy500/easy700/800 control relays as well as the MFD-Titan multi-function display come with a full range of technical resources to implement applications for industrial and building automation, machine building or plant construction. A host of different device versions with various functions, voltage types, expansion and networking options are available for implementing the right solution. As well as offering the main functions of the easy500/easy700 such as multi-function timing relays,counters, analog value comparators, time switchesetc., the easy800 and MFD-Titan offer a host of function blocks such as PID controllers, maths and value scaling function blocks and many more. The MFD-Titan also offers user-friendly operator and visualization options such as button functions, bitmaps or bar graphs as well as text displays, value entry and display functions. Protection to IP65 means that the display can be used in aggressive environments.

Moeller PS4 compact PLCs are all-in-one devices that are equipped with a comprehensive set of hardware and software functions and thus suitable for use in many industrial factory automation and building control applications. The devices can be simply expanded either locally using LE4 modules or via remote networks using EM4 modules. All the compact PLC are networkable and programmable via integrated fieldbus. The programming software applicable to all is Sucosoft S40, an easy-to-use programming package to IEC 61131-3.

easy500 Stand Alone

Eaton Moeller easy500 Programmable Relay
Inputs Outputs Further Features Supply Voltage Part Number
Digital Can be used for analog Relay 10A (UL) Transistor Display & Keypad Real-time clock
8 2 4 ~ 24 V AC EASY512-AB-RC
8 2 4 ~ ~ 24 V AC EASY512-AB-RCX
8 ~ 4 ~ ~ 100 - 240 V AC EASY512-AC-R
8 ~ 4 ~ 100 - 240 V AC EASY512-AC-RC
8 ~ 4 ~ ~ 100 - 240 V AC EASY512-AC-RCX
8 2 4 ~ 12 V DC EASY512-DA-RC
8 2 4 ~ ~ 12 V DC EASY512-DA-RCX
8 2 4 ~ ~ 24 V DC EASY512-DC-R
8 2 4 ~ 24 V DC EASY512-DC-RC
8 2 4 ~ ~ 24 V DC EASY512-DC-RCX
8 2 ~ 4 24 V DC EASY512-DC-TC
8 2 ~ 4 ~ 24 V DC EASY512-DC-TCX

easy700 Programmable Relay

Expandable: Digital inputs/outputs and bus systems AS-Interface, PROFIBUS-DP, CANopen, DeviceNet
Eaton Moeller easy700 Programmable Relay
Inputs Outputs Further Features Supply Voltage Part Number
Digital Can be used for analog Relay 10A (UL) Transistor Display & Keypad Real-time clock
12 4 6 ~ 24 V AC EASY719-AB-RC
12 4 6 ~ ~ 24 V AC EASY719-AB-RCX
12 ~ 6 ~ 100 - 240 V AC EASY719-AC-RC
12 ~ 6 ~ ~ 100 - 240 V AC EASY719-AC-RCX
12 4 6 ~ 12 V DC EASY719-DA-RC
12 4 6 ~ ~ 12 V DC EASY719-DA-RCX
12 4 6 ~ 24 V DC EASY719-DC-RC
12 4 6 ~ ~ 24 V DC EASY719-DC-RCX
12 4 ~ 8 24 V DC EASY719-DC-TC
12 4 ~ 8 ~ 24 V DC EASY719-DC-TCX

easy800 Programmable Relays

Expandable: Digital inputs/outputs and bus systems AS-Interface, CANopen, PROFIBUS-DP, DeviceNet
Eaton Moeller easy800 Programmable Relay
Inputs Outputs Further Features Supply Voltage Part Number
Digital Can be used for analog Relay 10A (UL) Transistor Analog Display & Keypad Real-time clock
12 ~ 6 ~ ~ 100 - 240 V AC EASY819-AC-RC
12 ~ 6 ~ ~ ~ 100 - 240 V AC EASY819-AC-RCX
12 4 6 ~ ~ 24 V DC EASY819-DC-RC
12 4 6 ~ ~ ~ 24 V DC EASY819-DC-RCX
12 4 6 ~ 1 24 V DC EASY820-DC-RC
12 4 6 ~ 1 ~ 24 V DC EASY820-DC-RCX
12 4 ~ 8 ~ 24 V DC EASY821-DC-TC
12 4 ~ 8 ~ ~ 24 V DC EASY821-DC-TCX
12 4 ~ 8 1 24 V DC EASY822-DC-TC
12 4 ~ 8 1 ~ 24 V DC EASY822-DC-TCX

easy800 bluetooth Adapter


Description Part Number
Bluetooth-Adapter EASY800-BLT-ADP

easy800 SmartWire-DT

  • Exchange of data as well as power supply for the SmartWire-DT devices and contactors via the communication systems SmartWire-DT
  • Up to 99 SmartWire-DT devices in total with up to 166 inputs/outputs can be connected
  • easyNet as well as 4 additional fast inputs, 2 of which can be used as fast outputs
  • Serial interface for programming or for connection of a remote text display or touch panel or for connection to the Ethernet
Description Supply Voltage Part Number
Control relay with SmartWire-DT 24 V DC EASY802-DC-SWD
Control relay with SmartWire-DT, 4 inputs, 2 of which can be
used as outputs (transistor 24 V DC, 0.1 A)., easyNET on board
EASY806-DC-SWD

MFD Titan Display / Operator Unit

Combines the functions of an easy800 with comfortable visualization for larger applications with
up to 320 I/O
Eaton Moeller MFD Titan Display/Operator Unit
Description Part Number
WITH keypad, WITH Eaton logotype. NEMA 4x in conjuction with MFD-XM-80
protective diaphragm
MFD-80-B
WITH keypad, WITHOUT Eaton logotype. NEMA 4x in conjuction with MFD-XM-80
protective diaphragm
MFD-80-B-X
WITHOUT keypad, WITH Eaton logotype. NEMA 4x MFD-80
WITHOUT keypad, WITH Eaton logotype. NEMA 4x MFD-80-X

MFD Titan Power Supply

Combinable with MFD-80-..display/operator unit and I/O module; expandable: digital/analog inputs/outputs and bus systems AS-Interface, CANopen, PROFIBUS-DP, DeviceNet; easyNet bus system optional on board, IP20m spring-loaded terminals
Eaton Moeller MFD Titan Power Supply - CPU Module Unit
Supply Voltage Description Part Number
100 - 240 V AC Program and screen memory MFD-AC-CP8-ME
100 - 240 V AC Program and screen memory,
with easyNet
MFD-AC-CP8-NT
24 V DC Program and screen memory MFD-CP8-ME
Program and screen memory,
with easyNet
MFD-CP8-NT
Double program and screen memory (as MFD-CP8) MFD-CP10-ME
Double program and screen memory (as MFD-CP8), with easyNet MFD-CP10-NT

MFD Titan I/O Modules

Eaton Moeller MFD Titan I/O Module
Supply Voltage For use with Inputs Outputs Temp. Ranges Part Number
Digital Can be used for analog Pt100 Relay 10a (UL) Trans-
istor
Analog
24 V DC MFD-CP8...
MFD-CP10...
12 4 ~ 4 ~ ~ ~ MFD-R16
24 V DC MFD-CP8...
MFD-CP10...
12 4 ~ ~ 4 ~ ~ MFD-T16
24 V DC MFD-CP8...
MFD-CP10...
12 4 ~ 4 ~ 1 ~ MFD-RA17
24 V DC MFD-CP8...
MFD-CP10...
12 4 ~ ~ 4 1 ~ MFD-TA17
100 - 240 V AC MFD-AC-CP8... 12 ~ ~ 4 ~ ~ ~ MFD-AC-R16

MFD Titan I/O Modules w/ Temp Detection

Eaton Moeller MFD Titan I/O Module with temp control
Supply Voltage For use with Inputs Outputs Temperature Ranges Part Number
Digital Can be used for analog Pt100 Relay 10a (UL) Trans-
istor
Analog
24 V DC MFD-CP8 from device version 08, MFD-CP10 6 2 2 ~ 4 ~ -40...+90°C
0...+250°C
0...+400°C
MFD-TP12-PT-A
6 2 2 ~ 4 ~ -200...+200°C
0...+850°C
MFD-TP12-PT-B
6 2 ~ ~ 4 ~ -40...+90°C
0...+250°C
MFD-TP12-NI-A
6 2 2 ~ 4 1 -40...90°C
0...+250°C
0...+400°C
MFD-TAP13-PT-A
6 2 2 ~ 4 1 -200..+200°C
0...+850°C
MFD-TAP13-PT-B
6 2 ~ ~ 4 1 -40+90°C
0...+250°C
MFD-TAP13-NI-A

easyControl

EC4P - CANopen/easyNet interface - Approvals UL/CSA - Shipping classifications DNV, GL, ABS, BV, LR
Eaton Moeller easyControl
Inputs Digital Outputs Analog Outputs Ethernet Display & Keypad Part Number
Digital Can be used for analog Relay Transistor
12 4 ~ 8 ~ ~ EC4P-221-MTXD1
12 4 ~ 8 ~ ~ ~ EC4P-221-MTXX1
12 4 6 ~ ~ ~ EC4P-221-MRXD1
12 4 6 ~ ~ ~ ~ EC4P-221-MRXX1
12 4 ~ 8 1 ~ EC4P-221-MTAD1
12 4 ~ 8 1 ~ ~ EC4P-221-MTAX1
12 4 6 ~ 1 ~ EC4P-221-MRAD1
12 4 6 ~ 1 ~ ~ EC4P-221-MRAX1
12 4 ~ 8 ~ EC4P-222-MTXD1
12 4 ~ 8 ~   EC4P-222-MTXX1
12 4 6 ~ ~ EC4P-222-MRXD1
12 4 6 ~ ~   EC4P-222-MRXX1
12 4 ~ 8 1 EC4P-222-MTAD1
12 4 ~ 8 1   EC4P-222-MTAX1
12 4 6 ~ 1 EC4P-222-MRAD1
12 4 6 ~ 1   EC4P-222-MRAX1

easyControl Software Accessories

Description Part Number
The programming software easySoft-Basic is used for programming easy500/700. "Drag & Drop" functions enable quick and comfortable entry of the circuit diagram. Programming is implemented in Ladder Diagram. Furthermore, the software offers the opportunity for simulation, on-line communication and documentation. easySoft-Basic
With easySoft-Pro, easy500/700/800, the multi-function display MFD-Titan, as well as easy800 with SmartWire-DT can be programmed. In addition to the functions of the easySoft-Basic, a screen editor for creation of the MFD Titan screens is available with the easySoft-pro. The integration of the SmartWire-DT line into the program occurred with the inclusion of the SmartWire-DT configurator. The easySoft-Pro CD contains a free OPC server, which enables the standardized inclusion of higher-level control systems (OPC clients). Just like easySoft-Basic, easySoft-Pro can be installed in 13 languages. easySoft-Pro
XSoft-CoDeSys-2 is the programming software for easyControl and the HMI-PLC. The software is based on standard CoDeSys from 3S for industrial PLCs in compliance with the international standard IEC 61131-3. The available programming languages are Instruction list (IL), Structured Text (ST), Function Block Diagram (FBD), Freely definable graphical function block chart/Continuous Function Chart (CFC), Ladder Diagram (LD) and Sequential Function Chart (SFC). The integrated online simulation facilitates program text even, when the control is not connected. Xsoft-CoDeSys-2
GALILEO is an easy-to-learn, and nevertheless powerful, visualization software. It is ideally suited for all machine and process-orientated applications in system and machine building. With its non-sector specific concept, GALILEO offers seamless project design for all Eaton Touch Panels. Simple placement of the objects by "Drag & Drop" and a clear menu guidance facilitate fast creation of a comfortable visualization system. This can be simulated directly on the development PC without connection to a HMI or a HMI-PLC. GALILEO

easyControl I/O Expansions (1)

can be used via easyLink
Digital Inputs Outputs Supply Voltage Part Number
Relay 10 A (UL) Transistor
12 6 ~ 100 - 240 V AC EASY618-AC-RE
12 ~ 8 24 V DC EASY620-DC-TC
12 6 ~ 24 V DC EASY618-DC-RE
~ 2 ~ 24V DC EASY202-RE
6 4 ~ 24 V DC EASY410-DC-RE
6 ~ 4 24 V DC EASY410-DC-TE
For distributed connection of a digital input/output expansion at up to 30m distance EASY200-EASY

easyControl I/O Expansions (2)

via CANopen can be used for: XC100/200, EC4P, XV
6 4 ~ 24 V DC EC4E-221-6D4R1
6 ~ 4 24 V DC EC4E-221-6D4T1

easyControl I/O Expansions (3)

can be used via easyLink
Inputs Digital Outputs Analog Outputs Supply Voltage Part Number
Digital/Analog Can be used for Digital Relay 10 A (UL) Transistor
1 / 2 2 ~ 2 1 24 V DC EASY406-DC-ME
1 / 6 2 ~ 2 2 24 V DC EASY411-DC-ME

easyC0ntrol Power Units

Power supply units, 1-phase. *Rated input voltage 100 - 240 V AC
Input voltage range Rated output voltage Output voltage setting range Rated output power Rated output current Part Number
85 - 264 V AC 24 V DC / 12 V DC ~ 8 W 0.35 A / 20 mA EASY200-POW
85 - 264 V AC 24 V DC ~ 30 W 1.25 A EASY400-POW
85 - 264 V AC 24 V DC ~ 60 W 2.5 A EASY500-POW
85 - 264 V AC 24 V DC ~ 100 W 4.2 A EASY600-POW

easySafety

Eaton Moeller easySafety Programmable Relays
Inputs
Outputs
Display Expansion
Communication
Circuit
Diagram
Part
Number
Safety
inputs
Safety
relay
outputs
safety
tran.
Outputs
Redundant
safety
relay
outputs
Test
Signals
easyNet easyLink Open
fieldbuses
Safety Standard
14 ~ 4 1 4 ~ up to
8 Net
stations
digital
I/O Standard
expansions
Profibus
DP CanOpen
DeviceNet AS-i
Yes Yes ES4P-221-DMXX1
14 ~ 4 1 4 Yes       Yes Yes ES4P-221-DMXD1
14 4 ~ ~ 4 ~       Yes Yes ES4P-221-DRXX1
14 4 ~ ~ 4 Yes       Yes Yes ES4P-221-DRXD1

easySafety (accessories)

Description Part Number
Memory Module ES4A-MEM-CARD1
easySoft-Safety + easySoft Pro ESP-Soft
Standard easy USB programming cable EASY800-USB-CAB
Standard easy serial programming cable EASY800-PC-CAB
I/O-Simulator ES4A-221-DMX-SIM

PS4-141/151

Eaton Moeller PS4-141-151 Programmable Relays
Rated
Voltage
Inputs Outputs Expandable by Part
Number
Digital
24V
DC
Digital
120/240V
AC
Analog Digital
24V
DC
Digital
120/240V
AC
Analog Suconet
K/K1
slaves
LE4 Max.
digital
I/O
24V
DC
16 ~ 2
10-bit
14 ~ 1
12-bit
8 ~ Total
680 I/O
PS4- 141-MM1
115-230V
AC
16 ~ 2
10-bit
8 ~ 1
12-bit
8 ~ Total
680 I/O
PS4- 151-MM1

PS4-141/151

Eaton Moeller PS4-201 Programmable Relays
Rated
Voltage
Inputs Outputs Expandable by Part
Number
Digital
24V
DC
Digital
120/240V
AC
Analog Digital
24V
DC
Digital
120/240V
AC
Analog Suconet
K/K1
slaves
LE4 Max.
digital
I/O
24V
DC
8 ~ 2
10-bit
6 ~ 1
12-bit
8
24
6 Total
790 I/O
PS4-201-MM1

PS4-141/151

Eaton Moeller PS$-271 Programmable Relays
Rated
Voltage
Inputs Outputs Expandable
by
Part
Number
Digital
24V
DC
Digital
120/240V
AC
Analog Digital
24V
DC
Digital
120/240V
AC
Analog Suconet
K/K1
slaves
LE4 Max.
digital
I/O
120-240V
AC
~ 12 4
10-bit
~ 8 4
12-bit
8
24
5 Total
790 I/O
PS4-271-MM1

PS4-341

Eaton Moeller PS4-341 Programmable Relays
Rated
Voltage
Inputs Outputs Expandable
by
Part
Number
Digital
24V
DC
Digital
120/240V
AC
Analog Digital
24V
DC
Digital
120/240V
AC
Analog Suconet
K/K1
slaves
LE4 Max.
digital
I/O
24 V DC 16 ~ 2
10-bit
14 ~ 1
12-bit
30
46
5 Total
8500 I/O
PS4-341-MM1

Digital and Analog I/O Modules - NOT Locally Expandable

Eaton Moeller Digital and Analog I/O Modules
Networking through Description Part Number
Suconet K1/K
  • 24 V DC supply
  • 8 inputs 24 V DC (10 inputs optional)
  • 8 outputs 24 V/0.5 A DC (6 outputs with 10 inputs)
  • Note: EM4-101-DD2 replaces.... DD1
EM4-101-DD2
Suconet K1/K
  • Supply voltage 115 - 230 V AC
  • 8 inputs, 24 V DC
  • 6 relay outputs, max. 230 V AC or 24 V DC
  • Note: EM4-111-DR2 replaces.... DR1
EM4-111-DR2

Analog Modules

Networking through Description Part Number
Suconet K1/K
  • Supply voltage 24 V DC, configurable inputs and outputs
  • 6/8 analog inputs, 8/12-bit resolution
  • 4 analog inputs, 8/12-bit resolution
EM4-101-AA2

Temperature Measuring Module

Networking through Description Part Number
Suconet K1/K
  • 24 V DC supply
  • 6 inputs for Pt100-/Ni1000 resistance thermomenters
        -- Pt100: -100 °C to +300 °C
        -- Ni1000: -50 °C to +150 °C
  • 8 outputs 24 V/0.5 A DC (6 outputs with 10 inputs)
  • 2 inputs 0 - 10 V, 12-bit resolution
EM4-101-TX1
Suconet K1/K
  • 24 V DC supply
  • 6 inputs for thermocouple types
        --0 °C to 1200 °C
        --K: 0 °C to 1300 °C
        --L: 0 °C to 900 °C
EM4-101-TX2

EMR-200 - Locally Expandable with Expansion Modules LE4-...

Eaton Moeller Digital and Analog I/O Modules
Networking through Description Part Number
Suconet K1/K
  • (EM4-201-DX2 replaces ....DX1)
EM4-201-DX2
PROFIBUS-DP
  • Supply voltage 24 V DC
  • 16 digital inputs
EM4-201-DX1

Digital and Analog I/O Modules - NOT Locally Expandable

Eaton Moeller LE4 PS4 Digital and Analog I/O Module
Description Part Number
  • 8 inputs, 24 V DC
  • 8 outputs (transistor) 24 V DC/0.5 A
LE4-116-DD1
  • 16 inputs (24 V DC)
LE4-116-DX1
  • 16 outputs (transistor) 24 V DC/0.5 A
LE4-116-XD1
  • 8 outputs (relays) 24 V DC/2.0A or 230 V AC/2.0 A
LE4-108-XR1
  • 8 outputs (transistor) 24 V DC/2.0 A
LE4-108-XD1
  • 8 outputs, 120/240 V AC
LE4-308-HX1
  • 8 outputs (Triac) 120 - 240 V AC
LE4-308-XH1

Analog Module

Description Part Number
  • 4 analog inputs -10 to +10 V
  • 2 analog outputs, -10/+10 mA, 10/12-bit resolution
LE4-206-AA1
  • 4 analog inputs, 0(4) to 20 mA, 12-bit resolution
  • 2 analog outputs, 0(4) to 20 mA, 12-bit resolution
LE4-206-AA2

Counter Modules

Description Part Number
  • 2 channels (25-bit count range)
  • 3 selectable operating modes per channel: path measurement system for 5V and 24V incremental encoders, fast counters for 24V encoders
  • Incremental path measurement
LE4-622-CX1

Absolute Encoder

Description Part Number
  • 3 channels (25-bit)
  • SSI interface/protocol
  • Transfer rate 125/250 kHz
LE4-633-CX1s

Network Modules

Description Part Number
  • for Suconet K
LE4-501-BS1
  • for PROFIBUS-FMS, slave function
LE4-503-BS1
  • for PROFIBUS-DP, master function
LE4-504-BS1
  • for PROFIBUS-DP, slave function
LE4-504-BT1

PS4 Accessories

Eaton Moeller PS4 Accessories
Memory Type Memory Size KByte Description For use with Part Number
Flash 64
64
  • Program memory backup
  • Recipe memory
PS4-150
PS4-200
ZB4-128-SF1
RAM 32
  • Expansion of the program memory from 24 kByte to 56 kByte
ZB4-032-SR1
Flash
Flash
RAM
64
64
32
  • Program memory backup
  • Recipe memory
  • Expansion of the program memory from 24 kByte to 56 kByte
ZB4-160-SM1
Flash
EEPROM
1000
  • Memory for backing up the user programs
  • Recipe memory
  • Usable from HW Version 2
PS4-300 ZB4-901-SF2

Programming Cable

Description For Use With Part Number
  • 1 x 8-pole pin connector (ZB4-108DS1), right angle version
  • 1 x 9-pole socket connector
  • Cable length 2 m
PS$-150
PS4-200
PS4-300
ZB4-303-KB1

Software

Description For Use With Part Number
  • Software package S40 (windows)
  • CD-ROM
  • Documentation on CD-ROM in English, French, German
  • Programming languages to IEC/EN 61131-3
        --Instruction list (IL)
        --Ladder diagram (LD)
        --Function block diagram (FBD)
        --Structured text (ST)
  • Dialog languages: English, French, German, Italian, Spanish
  • Graphical topology configurator for control systems, Suconet-K, and PROFIBUS-DP networks
PS$-150
PS4-200
PS4-300
PS416
S40-CD

10 sec Ramp, 1-Start per Hour, 300% Current Limit @ 40°C

DS7, Frame Size 1 Soft Start Contoller
Motor
Power (hp)
Motor
Power (kW)
24 Vac/Vdc 110/230 Vac 24 Vdc
for
SmartWire-DT
Rated
Current
(A)
200V 230V 460V Rated
Current
(A)
230V 400V
3.7 0.75 0.75 2 3.8 0.75 1.5 DS7-340SX004N0-N DS7-342SX004N0-N DS7-34DSX004N0-D
6.9 1.5 2 3 7 1.5 3 DS7-340SX007N0-N DS7-342SX007N0-N DS7-34DSX007N0-D
7.8 2 2 5 9 2.2 4 DS7-340SX009N0-N DS7-342SX009N0-N DS7-34DSX009N0-D
11 3 3 7.5 12 3 5.5 DS7-340SX012N0-N DS7-342SX012N0-N DS7-34DSX012N0-D
15.2 3 5 10 16 4 7.5 DS7-340SX016N0-N DS7-342SX016N0-N DS7-34DSX016N0-D
22 5 7.5 15 24 5.5 11 DS7-340SX024N0-N DS7-342SX024N0-N DS7-34DSX024N0-D
32 7.5 10 20 32 7.5 15 DS7-340SX032N0-N DS7-342SX032N0-N DS7-34DSX032N0-D
40 10 10 30 41 11 22 DS7-340SX041N0-N DS7-342SX041N0-N DS7-34DSX041N0-D
52 15 20 40 55 15 30 DS7-340SX055N0-N DS7-342SX055N0-N DS7-340SX055N0-D
65 20 25 50 68 15 37 DS7-340SX070N0-N DS7-342SX070N0-N DS7-34DSX070N0-D
77 25 30 60 81 22 54 DS7-340SX081N0-N DS7-342SX081N0-N DS7-34DSX081N0-D
96 30 30 75 99 30 55 DS7-340SX100N0-N DS7-342SX100N0-N DS7-34DSX100N0-D
124 40 50 100 134 30 75 DS7-340SX135N0-N DS7-342SX135N0-N DS7-34DSX135N0-D
156 50 60 125 160 45 90 DS7-340SX160N0-N DS7-342SX160N0-N DS7-34DSX160N0-D
180 60 75 150 196 55 110 DS7-340SX200N0-N DS7-342SX200N0-N DS7-34DSX200N0-D

10 sec Ramp, 1-Start per Hour, 400% Current Limit @ 40°C

DS7 F3, Frame Size 3 Soft Start Contoller
Motor
Power (hp)
Motor
Power (kW)
24 Vac/Vdc 110/230 Vac 24 Vdc
for
SmartWire-DT
Rated
Current
(A)
200V 230V 460V Rated
Current
(A)
230V 400V
3 0.5 0.5 1.5 2.5 0.33 1 DS7-340SX004N0-N DS7-342SX004N0-N DS7-34DSX004N0-D
4.8 1 1 3 3.8 0.75 1.5 DS7-340SX007N0-N DS7-342SX007N0-N DS7-34DSX007N0-D
6.9 1.5 2 3 7 1.5 3 DS7-340SX009N0-N DS7-342SX009N0-N DS7-34DSX009N0-D
9 2 2 5 9 2.2 4 DS7-340SX012N0-N DS7-342SX012N0-N DS7-34DSX012N0-D
11 3 3 7.5 12 3 5.5 DS7-340SX016N0-N DS7-342SX016N0-N DS7-34DSX016N0-D
17.5 5 5 10 16 4 7.5 DS7-340SX024N0-N DS7-342SX024N0-N DS7-34DSX024N0-D
22 5 7.5 15 24 5.5 11 DS7-340SX032N0-N DS7-342SX032N0-N DS7-34DSX032N0-D
27 7.5 10 20 28.8 7.5 11 DS7-340SX041N0-N DS7-342SX041N0-N DS7-34DSX041N0-D
34 10 10 30 37.5 11 18.5 DS7-340SX055N0-N DS7-342SX055N0-N DS7-34DSX055N0-D
40 15 15 30 46 11 22 DS7-340SX070N0-N DS7-342SX070N0-N DS7-34DSX070N0-D
52 15 20 40 56 15 30 DS7-340SX081N0-N DS7-342SX081N0-N DS7-34DSX081N0-D
65 20 25 50 68 18.5 37 DS7-340SX100N0-N DS7-342SX100N0-N DS7-34DSX100N0-D
80 30 30 75 90 22 45 DS7-340SX135N0-N DS7-342SX135N0-N DS7-34DSX135N0-D
96 30 40 75 106 30 55 DS7-340SX160N0-N DS7-342SX160N0-N DS7-34DSX160N0-D
124 40 50 100 134 37 75 DS7-340SX200N0-N DS7-342SX200N0-N DS7-34DSX200N0-D

10 sec Ramp, 1-Start per Hour, 300% Current Limit @ 40°C

S701 Soft Start Controller
Rated
Current
Line
Voltage
Control
Voltage
(Vac/Vdc)
Part
Number
3.5 208–240 24–230 S701C03N3S
3.5 380–415 24–415 S701D03N3S
3.5 440–480 24–480 S701E03N3S
3.5 500–600 24–480 S701G03N3S
15 208–240 24–230 S701C15N3S
15 380–480 24–480 S701E15N3S
15 500–600 24–480 S701G15N3S
25 208–240 24–230 S701C25N3S
25 380–480 24–480 S701E25N3S
25 500–600 24–480 S701G25N3S

S701 Soft Start Controllers with Auxiliary Contact

S701 Soft Start Controllers with Auxiliary Contact
Rated
Current
Line
Voltage
Control
Voltage
(Vac/Vdc)
Part
Number
Ratings without Bypass
25 208–240 24–230 S701C25N3BP
25 380–480 24–480 S701E25N3BP
25 500–600 24–480 S701G25N3BP
Ratings with Bypass
30 208–240 24–230 S701C25N3BP
30 380–480 24–480 S701E25N3BP
30 500–600 24–480 S701G25N3BP

S701 Soft Start Controllers with Brake

S701 Soft Start Controllers with Brake
Rated
Current
Line
Voltage
Control
Voltage
(Vac/Vdc)
Part
Number
25 208–240 24–230 S701C25B3S
25 380–480 24–480 S701E25B3S
S511 Semiconductor Reversing Contactor
Rated
Current
Line
Voltage
Control
Voltage
Part
Number
10 208–480 5–24 Vdc S511E10N3D
10 208–480 24–240 Vac/Vdc S511E10N3S

Standard Duty - 300% Current for 15 Seconds, 115% Continuous

Type S611, Soft Starter
Rated
Current (Amps)
Horsepower Rating Part
Number
208V 240 V 480 V 600 V
52 15 15 40 50 S611A052N3S
65 20 20 50 60 S611A065N3S
77 25 25 60 75 S611A077N3S
99 30 30 75 100 S611B099N3S
125 40 40 100 125 S611B125N3S
156 50 60 125 150 S611C156N3S
180 60 60 150 150 S611C180N3S
242 75  75 200 250 S611D242N3S
302 100 100 250 300 S611E302N3S
361 125 150 300 350 S611E361N3S
414 150 150 350 450 S611F414N3S

Standard Duty Plus - 350% FLA for 30 Seconds, 115% Continuous

Type S611, Soft Starter
Rated
Current (Amps)
Horsepower Rating Part
Number
208V 240 V 480 V 600 V
52 15 15 40 50 S611A052N3S
65 20 20 50 60 S611A065N3S
71 20 25 60 75 S611A077N3S
99 30 30 75 100 S611B099N3S
119 40 40 100 125 S611B125N3S
156 50 60 125 150 S611C156N3S
180 60 60 150 150 S611C180N3S
242 75 75 200 250 S611D242N3S
302 100 100 250 300 S611E302N3S
361 125 150 300 350 S611E361N3S
407 150 150 350 400 S611F414N3S

Heavy Duty - 500% FLA for 30 Seconds, 125% Continuous

Type S611, Soft Starter
Rated
Current (Amps)
Horsepower Rating Part
Number
208V 240 V 480 V 600 V
49 15 15 40 50 S611A052N3S
83 25 30 60 75 S611B099N3S
142 40 60 125 150 S611C156N3S
225 75 75 200 200 S611D242N3S
256 75 100 200 250 S611E361N3S
285 100 125  250 300 S611F414N3S

Severe Duty - 600% FLA for 30 Seconds, 125% Continuous

Type S611, Soft Starter
Rated
Current (Amps)
Horsepower Rating Part
Number
208V 240 V 480 V 600 V
41 10 15 30 40 S611A052N3S
69 20 30 60 60 S611B099N3S
117 30 50 100 125 S611C180N3S
187 60 75 150 200 S611D242N3S
213 75 75 150 200 S611E361N3S
238 75 100 200 250 S611F414N3S
Type S611, Soft Starter
Frame
Size
Standard Duty
15 Second Ramp
300% Current Limit
at 40°C
Inline Connection
Rated Current
Sever Duty
>30 Second Ramp
300% Current Limit
Rated Current
Part
Number
N 37 22 S801+N37N3S
66 42 S801+N66N3S
R 105 65 S801+R10N3S
135 80 S801+R13N3S
T 180 115 S801+T18N3S
240 150 S801+T24N3S
304 192 S801+T30N3S
U 360 240 S801+U36N3S
420 305 S801+U42N3S
500 365 S801+U50N3S (1)
V 360 240 S801+V36N3S
420 305 S801+V42N3S
500 365 S801+V50N3S
650 420 S801+V65N3S
720 480 S801+V72N3S
850 525 S801+V85N3S
1000 600 S801+V10N3S

10 sec Ramp, 1-Start per Hour, 300% Current Limit @ 40°C

Type S811+ Soft Starter with DIM
Frame
Size
Standard
Duty
15 sec Ramp
300% Current Limit
40°C Inline
Rated Current
Sever
Duty
30 sec Ramp
450% Current Limit
50°C Inline
Rated Current
Standard
Duty
15 sec Ramp
300% Current Limit
40°C Inside-the-Delta
Rated Current
Sever
Duty
30 sec Ramp
450% Current Limit
50°C Inside-the-Delta
Rated Current
Part
Number (1)
N 37 22 65 39 S811+N37N3S
66 42 114 73 S811+N66N3S
R 105 65 183 111 S811+R10N3S
135 80 234 138 S811+R13N3S
T 180 115 311 199 S811+T18N3S
240 150 415 257 S811+T24N3S
304 192 526 324 S811+T30N3S
U 360 240 623 415 S811+U36N3S
420 305 727 526 S811+U42N3S
500 110 865 623 S811+U50N3S(2)
V 360 240 623 415 S811+V36N3S
429 305 727 526 S811+V42N3S
500 365 865 623 S811+V50N3S
650 420 1125 727 S811+V65N3S
720 480 1246 816 S811+V72N3S
850 525 1471 908 S811+V85N3S
1000 575 S811+V10N3S

S811+ Premium

In addition to what is already there in the S811+ standard, these devices offer pump control and extended ramp functions.
Current Range Part Number
11 - 37 S811+N37P3S
20 - 66 S811+N66P3S
32 - 105 S811+R10P3S
42 - 135 S811+R13P3S
56 - 180 S811+T18P3S
75 - 240 S811+T24P3S
95 - 304 S811+T30P3S
112 - 360 S811+U36P3S
131 - 420 S811+U42P3S
156 - 500 S811+U50P3S(1)
112 - 360 S811+V36P3S
131 - 420 S811+V42P3S
165 - 500 S811+V50P3S
203 - 650 S811+V65P3S
225 - 720 S811+V72P3S
265 - 850 S811+V85P3S
312 - 1000 S811+V10P3S
NOTE:
(1) S811+U50 unit does not have IEC certification.

S811+ Premium 690 V Option

In addition to what is already there in S811+ standard, this product offers 690 V, pump control and extended ramp functions.
Current Range Part Number
56 - 180 S811+T18V3S
75 - 240 S811+T24V3S
93 - 304 S811+T30 V3S
112 - 360 S811+V36V3S
131 - 420 S811+V42V3S
156 - 500 S811+V50 V3S
203 - 650 S811+V65V3S
225 - 720 S811+V72V3S
265 - 850 S811+V85V3S

Experts in Part Replacement - Same Day Shipping 
Call Now! (866) 595-9616