Description |
S701C03N3S |
S701D03N3S |
S701E03N3S |
S701G03N3S |
Maximum
current capacity |
3.5 |
3.5 |
3.5 |
3.5 |
Trip Class - 10A |
3.5 |
3.5 |
3.5 |
3.5 |
Trip Class - 10 |
3.5 |
3.5 |
3.5 |
3.5 |
Trip Class - 20 |
2.8 |
2.8 |
2.8 |
2.8 |
Trip Class - 30 |
2.1 |
2.1 |
2.1 |
2.1 |
Electrical Characteristics |
Line voltage (Vac) |
208–240 |
380–415 |
440–480 |
500–600 |
Operating frequency (Hz) |
50/60 |
50/60 |
50/60 |
50/60 |
Leakage current |
5 mA AC max. |
5 mA AC max. |
5 mA AC max. |
5 mA AC max. |
Minimum
operational current |
50 mA |
50 mA |
50 mA |
50 mA |
Control voltage
(Vac/Vdc) |
24–230 |
24–415 |
24–480 |
24–480 |
Pickup voltage max. |
20.4 Vac/Vdc |
20.4 Vac/Vdc |
20.4 Vac/Vdc |
20.4 Vac/Vdc |
Dropout voltage min. |
5 Vac/Vdc |
5 Vac/Vdc |
5 Vac/Vdc |
5 Vac/Vdc |
Max. control current
for no operation |
1 mA |
1 mA |
1 mA |
1 mA |
Response time max. |
70 ms |
70 ms |
70 ms |
70 ms |
Control Characteristics |
Ramp time (secs) |
0.5–10 |
0.5–10 |
0.5–10 |
0.5–10 |
Ramp settings
(% LRT) |
85% |
85% |
85% |
85% |
Kick start settings
(% LRT) |
85% |
85% |
85% |
85% |
Soft stop (secs) |
0.5–10 |
0.5–10 |
0.5–10 |
0.5–10 |
Environment Characteristics |
Temperature–operating
(no derating) |
–30° to 40° C |
–30° to 40° C |
–30° to 40° C |
–30° to 40° C |
Current rating 50° C |
N/A |
N/A |
N/A |
N/A |
Limited duty cycle 50° C |
N/A |
N/A |
N/A |
N/A |
Current rating 60° C |
N/A |
N/A |
N/A |
N/A |
Limited duty cycle 60° C |
N/A |
N/A |
N/A |
N/A |
Temperature–storage |
–30° to 80° C |
–30° to 80° C |
–30° to 80° C |
–30° to 80° C |
Altitude (meters)
no derating |
2000 |
2000 |
2000 |
2000 |
Humidity |
95%
noncondensing |
95%
noncondensing |
95%
noncondensing |
95%
noncondensing |
Operating position
(no derating) |
Vertical ±30° |
Vertical ±30° |
Vertical ±30° |
Vertical ±30° |
Impulse withstand
voltage IEC 947-4-1 |
4000 V |
4000 V |
4000 V |
4000 V |
Rated insulation
voltage (Ui) |
660 V |
660 V |
660 V |
660 V |
Installation category |
III |
III |
III |
III |
Vibration |
IEC 68-2-6 5g
10–150 Hz |
IEC 68-2-6 5g
10–150 Hz |
IEC 68-2-6 5g
10–150 Hz |
IEC 68-2-6 5g
10–150 Hz |
Power dissipation
for intermittent operation |
4 W/A x duty cycle |
4 W/A x duty cycle |
4 W/A x duty cycle |
4 W/A x duty cycle |
Power dissipation
for continuous operation |
4 W/A x duty cycle |
4 W/A x duty cycle |
4 W/A x duty cycle |
4 W/A x duty cycle |
Cooling method |
Natural convection |
Natural convection |
Natural convection |
Natural convection |
Degree of protection |
IP20 |
IP20 |
IP20 |
IP20 |
Pollution degree |
3 |
3 |
3 |
3 |
Agency approvals |
UL, cUL, CE |
UL, cUL, CE |
UL, cUL, CE |
UL, cUL, CE |