Eaton Space Saver - Contactors, Starters & Overload Relays
Type CN13/53 Space-Savings NEMA Contactors
Non-Reversing and Reversing
Notes
(1) Available on Compact Size 1 starter only.
(2) Gold A indicates coils suffix required, see Coil Suffix table
below.
(3) NEMA Size 5 starter available with 60-300A panel mounted CTs. Starter shipped as an assembled unit with
1–5A C440 overload relay (C440A1A005SELAX or C440A2A005SELAX).
Type AN13/53 Space-Savings Starters with XTOE Electronic Overload Relays
Non-Reversing and Reversing
Notes
(1) Gold A indicates coils suffix required, see Coil Suffix table above.
(2) Underscore (_) indicates OLR designation required, see XTOE FLA Range table above.
(3) NEMA Size 5 starter available with 60-300A panel mounted CTs. Starter shipped as an assembled unit with
1–5A C440 overload relay (C440A1A005SELAX or C440A2A005SELAX).
(4) Not available on AN13DN or AN53DN starters.
Type AN13/53 Space-Savings Starters with XTOE Ground Fault Electronic Overload Relays
Non-Reversing and Reversing
NEMA
Size |
Continuous
Ampere
Rating |
Service
Limit
Current
Rating (Amps) |
Maximum
UL Horsepower
Three-Phase |
Standard
MCC
Bucket Size |
Three-Pole
Non-Reversing (1)(2)
Part Number |
Three-Pole
Reversing (1)(2)
Part Number |
230V |
480V |
0 |
18 |
21 |
2 |
5 |
Not offered |
AN13BN0A5G _ |
AN53BN0A5G _ |
1C |
27 |
32 |
3 |
10 |
Not offered |
AN13CN0A5G _ |
AN53CN0A5G _ |
1 |
27 |
32 |
3 |
10 |
2X |
AN13DN0A5G _ |
AN53DN0A5G _ |
2 |
45 |
52 |
7-1/2 |
25 |
2X |
AN13GN0A5G _ |
AN53GN0A5G _ |
3 |
90 |
104 |
- |
50 |
4X |
AN13KN0A5G _ |
AN53KN0A5G _ |
4 |
135 |
156 |
- |
100 |
4X |
AN13NN0A5G_ |
AN53NN0A5G _ |
5 (3) |
270 |
311 |
- |
200 |
8X |
AN13SN0A5G _ |
AN53SN0A5G _ |
Notes
(1) Gold A indicates coils suffix required, see Coil Suffix table above.
(2) Underscore (_) indicates OLR designation required, see XTOE FLA Range table above.
(3) NEMA Size 5 starter available with 60-300A panel mounted CTs. Starter shipped as an assembled unit with
1–5A C440 overload relay (C440A1A005SELAX or C440A2A005SELAX).
(4) Not available on AN13DN or AN53DN starters.
XTOE Overload FLA Range (FVNR and FVR Starters Only) Magnet Coil Suffix
NEMA Size |
OLR Code |
FLA Range |
OLR Code |
FLA Rating |
0 |
1P6 |
0.33-1.65A |
020 |
4.0-20A |
005 |
1.0-5.0A |
- |
- |
1C/1 |
1P6 (4) |
0.33-1.65A |
020 |
4.0-20A |
005 |
1.0-5.0A |
045 |
9.0-45A |
2 |
- |
- |
045 |
9.0-45A |
- |
- |
- |
- |
3 |
100 |
20-100A |
- |
- |
4 |
175 |
35-175A |
- |
- |
5 (3) |
300 |
60-300A |
- |
- |
Coil Voltage |
Suffix Code |
Sizes 0-2 |
110V 50 Hz, 120V 60 Hz |
A |
220V 50 Hz, 240V 60 Hz |
B |
24-27 Vdc |
TD |
Sizes 3, 4 |
100-120V 50/60 Hz |
A |
190-240V 50/60 Hz |
B |
24-27 Vdc |
TD |
Sizes 5 |
100-120V 50/60 Hz |
A |
24-48 Vdc |
TD |
Notes
(1) Gold A indicates coils suffix required, see Coil Suffix table above.
(2) Underscore (_) indicates OLR designation required, see XTOE FLA Range table above.
(3) NEMA Size 5 starter available with 60-300A panel mounted CTs. Starter shipped as an assembled unit with
1–5A C440 overload relay (C440A1A005SELAX or C440A2A005SELAX).
(4) Not available on AN13DN or AN53DN starters.