Description |
Size 0
CN13BN010_ |
Size 1C
CN13CN010_ |
Size 1
CN13DN000_ |
Size 2
CN13GN000_ |
General |
Standards |
IEC/EN 60947,
VDE 0660, UL,
CSA,
CCC, RoHS |
IEC/EN 60947,
VDE 0660, UL,
CSA,
CCC, RoHS |
IEC/EN 60947,
VDE 0660, UL,
CSA,
CCC, RoHS |
IEC/EN 60947,
VDE 0660, UL,
CSA,
CCC, RoHS |
Weights in kg [lb]
AC operated |
0.42 [0.93] |
0.42 [0.93] |
0.9 [2.0] |
0.9 [2.0] |
Weights in kg [lb]
DC operated |
0.48 [1.06] |
0.48 [1.06] |
1.1 [2.4] |
1.1 [2.4] |
Mechanical life
operations |
10,000,000 |
10,000,000 |
10,000,000 |
10,000,000 |
Climatic proofing |
(1) |
(1) |
(1) |
(1) |
Insulation voltage
(Ui) Vac |
690 |
690 |
690 |
690 |
Impulse withstand
voltage (Uimp) Vac |
8000 |
8000 |
8000 |
8000 |
Operating voltage
(Ue) Vac |
690 |
690 |
690 |
690 |
Safe isolation to
VDE 0106 Part 101
and Part 101/A1
Between coil and
contacts (Vac) |
440 |
440 |
440 |
440 |
Safe isolation to
VDE 0106 Part 101
and Part 101/A1
Between contacts (Vac) |
238 |
440 |
440 |
440 |
Making capacity (amps) |
238 |
384 |
560 |
910 |
Breaking capacity (amps)
220/230V |
170 |
320 |
400 |
650 |
Breaking capacity (amps)
380/400V |
170 |
320 |
400 |
650 |
Breaking capacity (amps)
500V |
170 |
320 |
400 |
650 |
Breaking capacity (amps)
660/690V |
120 |
180 |
250 |
370 |
Short-circuit protection rating maximum fuse
(amps)
Type 2 coordination(2) |
400V; gG/gL 500V |
25 |
63 |
63 |
125 |
690V; gG/gL 690V |
25 |
35 |
50 |
80 |
Type 1 coordination(2) |
400V; gG/gL 500V |
63 |
125 |
125 |
250 |
690V; gG/gL 690V |
50 |
63 |
80 |
100 |
Degree of protection |
IP00 |
IP00 |
IP00 |
IP00 |
Protection against
direct contact when
actuated from
front (IEC 536) |
Finger and
back-of-hand
proof |
Finger and
back-of-hand
proof |
Finger and
back-of-hand
proof |
Finger and
back-of-hand
proof |
Terminal capacity main cable—screw terminals |
Solid (mm2) |
1 x (0.75–16)
2 x (0.75–10) |
1 x (0.75–16)
2 x (0.75–10) |
1 x (0.75–16)
2 x (0.75–10) |
1 x (0.75–16)
2 x (0.75–10) |
Flexible with
ferrule (mm2) |
1 x (0.75–16)
2 x (0.75–10) |
1 x (0.75–16)
2 x (0.75–10) |
1 x (2.5–35)
2 x (2.5–25) |
1 x (2.5–35)
2 x (2.5–25) |
Stranded (mm2) |
1 x 16 |
1 x 16 |
1 x (16–50)
2 x (16–35) |
1 x (16–50)
2 x (16–35) |
Solid or stranded (AWG) |
18–6 |
18–6 |
12–2 |
12–2 |
Flat conductor
(number of segments x
width x thickness) (mm) |
— |
— |
2 x (6 x 9 x 0.8) |
2 x (6 x 9 x 0.8) |
Main cable connection
screw/bolt |
M5 |
M5 |
M6 |
M6 |
Tightening torque
Nm |
3 |
3 |
3.3 |
3.3 |
Tightening torque
Lb-in |
26.6 |
26.6 |
29.2 |
29.2 |
Terminal capacity controlcircuit cable—screw
terminals |
Solid (mm2) |
1 x (0.75–4)
2 x (0.75–4) |
1 x (0.75–4)
2 x (0.75–4) |
1 x (0.75–4)
2 x (0.75–4) |
1 x (0.75–4)
2 x (0.75–4) |
Flexible with ferrule
(mm2) |
1 x (0.75–2.5)
2 x (0.75–2.5) |
1 x (0.75–2.5)
2 x (0.75–2.5) |
1 x (0.75–2.5)
2 x (0.75–2.5)
|
1 x (0.75–2.5)
2 x (0.75–2.5) |
Solid or stranded (AWG) |
18–14 |
18–14 |
18–14 |
18–14 |
Control circuit cable
connection screw/bolt |
M3.5 |
M3.5 |
M3.5 |
M3.5 |
Tightening torque
Nm |
1.2 |
1.2 |
1.2 |
1.2 |
Tightening torque
Lb-in |
10.6 |
10.6 |
10.6 |
10.6 |
Tools |
Main and control
circuit cable -
screw terminals |
Size 2 |
Size 2 |
Size 2 |
Size 2 |
Pozidriv screwdriver |
0.8 x 5.5 |
0.8 x 5.5 |
0.8 x 5.5 |
0.8 x 5.5 |
Standard screwdriver |
1 x 6 |
1 x 6 |
1 x 6 |
1 x 6 |
Terminal capacity control circuit
cable—spring cage terminals |
Solid (mm2)
|
1 x (0.75–2.5)
2 x (0.75–2.5) |
1 x (0.75–2.5)
2 x (0.75–2.5) |
1 x (0.75–2.5)
2 x (0.75–2.5) |
1 x (0.75–2.5)
2 x (0.75–2.5) |
Flexible (mm2)
|
1 x (0.75–2.5)
2 x (0.75–2.5) |
1 x (0.75–2.5)
2 x (0.75–2.5)
|
1 x (0.75–2.5)
2 x (0.75–2.5) |
1 x (0.75–2.5)
2 x (0.75–2.5) |
Flexible with ferrule (mm2)
|
1 x (0.75–2.5)
2 x (0.75–2.5) |
1 x (0.75–2.5)
2 x (0.75–2.5) |
1 x (0.75–2.5)
2 x (0.75–2.5) |
1 x (0.75–2.5)
2 x (0.75–2.5) |
Solid or stranded (AWG) |
18–14 |
18–14 |
18–14 |
18–14 |
Tools
Main and control
circuit cable—spring cage terminals
Stripping length (mm) |
10 |
10 |
10 |
10 |
Screwdriver blade width (mm) |
3.5 |
3.5 |
3.5 |
3.5 |
Mounting position,
AC and DC operated |
|
|
|
|
Ambient temperature
Open |
–25 to 60°C
[–13 to 140°F] |
–25 to 60°C
[–13 to 140°F] |
–25 to 60°C
[–13 to 140°F] |
–25 to 60°C
[–13 to 140°F] |
Ambient temperature
Enclosed |
–25 to 40°C
[–13 to 104°F] |
–25 to 40°C
[–13 to 104°F] |
–25 to 40°C
[–13 to 104°F] |
–25 to 40°C
[–13 to 104°F] |
Ambient storage
temperature |
–40 to 80°C
[–40 to 176°F] |
–40 to 80°C
[–40 to 176°F] |
–40 to 80°C
[–40 to 176°F] |
–40 to 80°C
[–40 to 176°F] |
Environmental - Mechanical shock resistance
(IEC/EN 60068-2-27) |
Main contact -
NO Contact |
10 |
10 |
10 |
10 |
Auxiliary contact -
NO Contact |
7 |
7 |
7 |
7 |
Auxiliary contact -
NC Contact |
5 |
5 |
5 |
5 |
Overvoltage category/
pollution degree |
III/3 |
III/3 |
III/3 |
III/3 |
Description |
Specification |
45 mm |
55 mm |
110 mm |
Electrical Ratings |
Range |
Range |
Range |
Operating voltage (three-phase)
and frequency |
690 Vac (60/50 Hz) |
690 Vac (60/50 Hz) |
690 Vac (60/50 Hz) |
FLA Range |
0.33–1.65A
1–5A
4–20A
9–45A |
20–100A |
28–140A (NEMA)
35–175A (IEC) |
Use with Contactors
Space-Savings NEMA Size |
0, 1C |
1, 2, 3 |
4 |
Trip Class |
10A, 10, 20, 30
Selectable |
10A, 10, 20, 30
Selectable |
10A, 10, 20, 30
Selectable |
Motor Protection
Thermal overload setting |
1.05 x FLA: does not trip
1.15 x FLA: overload trip |
1.05 x FLA: does not trip
1.15 x FLA: overload trip |
1.05 x FLA: does not trip
1.15 x FLA: overload trip |
Phase loss |
Fixed threshold 50% |
Fixed threshold 50% |
Fixed threshold 50% |
Phase unbalance
(selectable: enable/disable) |
Fixed threshold 50% |
Fixed threshold 50% |
Fixed threshold 50% |
Ground fault
(selectable: enable/disable) |
50% of FLA dial setting
>150% = 2 sec
>250% = 1 sec |
50% of FLA dial setting
>150% = 2 sec
>250% = 1 sec |
50% of FLA dial setting
>150% = 2 sec
>250% = 1 sec |
Reset |
Manual/automatic |
Manual/automatic |
Manual/automatic |
Trip status |
Orange flag |
Orange flag |
Orange flag |
Mode LED |
One flash:
Overload operating
properly
Two flashes:
Current is above
FLA dial
setting—
pending trip |
One flash:
Overload operating
properly
Two flashes:
Current is above
FLA dial
setting—
pending trip |
One flash:
Overload operating
properly
Two flashes:
Current is above
FLA dial
setting—
pending trip |
Remote reset |
Yes |
Yes |
Yes |
Reset bar |
Yes |
Yes |
Yes |
Communication
expansion module |
Yes |
Yes |
Yes |
Communication adapter |
Yes |
Yes |
Yes |
Load terminals
Terminal capacity |
12–10 AWG (4–6 mm2)
8–6 AWG (6–16 mm2) |
6–1 AWG (16–50 mm2) |
8–4/0 AWG (10–95 mm2) |
Load terminals
Tightening torque |
20–25 lb-in (2.3–2.8 Nm)
25–30 lb-in (2.8–3.4 Nm) |
25–30 lb-in (2.8–3.4 Nm) |
124 lb-in (14 Nm) |
Input, auxiliary contact
and remote reset terminals
Terminal capacity |
2 x (18–12) AWG |
2 x (18–12) AWG |
2 x (18–12) AWG |
Input, auxiliary contact
and remote reset terminals
Tightening torque |
7–11 lb-in (0.8–1.2 Nm) |
7–11 lb-in (0.8–1.2 Nm) |
7–11 lb-in (0.8–1.2 Nm) |
Voltages |
Insulation voltage Ui
(three-phase) |
690 Vac |
690 Vac |
690 Vac |
Insulation
voltage Ui (control) |
500 Vac |
500 Vac |
500 Vac |
Rated impulse
withstand voltage |
6000 Vac |
6000 Vac |
6000 Vac |
Overvoltage category/
pollution degree |
III/3 |
III/3 |
III/3 |
Auxiliary and Control Circuit Ratings |
Conventional thermal
continuous current |
5A |
5A |
5A |
Rated operational current
—IEC AC-15
Make contact (1800 VA) |
|
120V |
15A |
15A |
15A |
240V |
15A |
15A |
15A |
415V |
0.5A |
0.5A |
0.5A |
500V |
0.5A |
0.5A |
0.5A |
Break contact (180 VA) |
|
120V |
1.5A |
1.5A |
1.5A |
240V |
1.5A |
1.5A |
1.5A |
415V |
0.9A |
0.9A |
0.9A |
500V |
0.8A |
0.8A |
0.8A |
IEC DC-13 (L/R F 15 ms1) |
|
0–250V |
1.0A |
1.0A |
1.0A |
Rated operational current
UL B600
Make contact (3600 VA) |
|
120V |
30A |
30A |
30A |
240V |
15A |
15A |
15A |
480V |
7.5A |
7.5A |
7.5A |
600V |
6A |
6A |
6A |
Break contact (360 VA) |
|
120V |
3A |
3A |
3A |
240V |
1.5A |
1.5A |
1.5A |
480V |
0.75A |
0.75A |
0.75A |
600V |
0.6A |
0.6A |
0.6A |
R300—Vdc ratings (28 VA) |
|
0–120V |
0.22A |
0.22A |
0.22A |
250V |
0.11A |
0.11A |
0.11A |
Short-Circuit Rating without Welding |
Maximum fuse |
6A gG/gL |
6A gG/gL |
6A gG/gL |
Environmental Ratings |
Ambient temperature
(operating) |
–13° to 149°F
(–25° to 65°C) |
–13° to 149°F
(–25° to 65°C) |
–13° to 149°F
(–25° to 65°C) |
Ambient temperature
(storage) |
–40° to 185°F
(–40° to 85°C) |
–40° to 185°F
(–40° to 85°C) |
–40° to 185°F
(–40° to 85°C) |
Operating humidity
UL 991 (H3) |
5% to 95%
noncondensing |
5% to 95%
noncondensing |
5% to 95%
noncondensing |
Altitude (no derating)
NEMA ICS1 |
2000m |
2000m |
2000m |
Shock
(IEC 600068-2-27) |
15g any direction |
15g any direction |
15g any direction |
Vibration
(IEC 60068-2-6) |
3g any direction |
3g any direction |
3g any direction |
Pollution degree per
IEC 60947-4-1 |
3 for product (2 for pcb) |
3 for product (2 for pcb) |
3 for product (2 for pcb) |
Ingress protection |
IP20 |
IP20 |
IP20 |
Protection against direct
contact when actuated from
front (IEC 536) |
Finger- and
back-of-hand proof |
Finger- and
back-of-hand proof |
Finger- and
back-of-hand proof |
Mounting position |
Any |
Any |
Any |
Climatic proofing |
Damp heat,
constant to
IEC 60068-2-30 |
Damp heat,
constant to
IEC 60068-2-30 |
Damp heat,
constant to
IEC 60068-2-30 |
Electrical/EMC |
Radiated emissions
IEC 60947-4-1-Table 15
EN 55011 (CISPIR 11)
Group 1, Class A, ISM
|
30 MHz to
1000 MHz |
30 MHz to
1000 MHz |
30 MHz to
1000 MHz |
Conducted emissions
IEC 60947-4-1-Table 14
EN 55011 (CISPIR 11)
Group 1; Class ISM |
0.15 MHz to
30 MHz |
0.15 MHz to
30 MHz |
0.15 MHz to
30 MHz |
ESD immunity
IEC 60947-4-1 |
±8 kV air,
±6 kV contact |
±8 kV air,
±6 kV contact |
±8 kV air,
±6 kV contact |
Radiated immunity
IEC 60947-4-1
IEC 61000-4-3 |
10 V/m 80
MHz–1000 MHz
3 V/m from
1.4 to 2.7 GHz
80% amplitude
modulated
1 kHz sine wave |
10 V/m 80
MHz–1000 MHz
3 V/m from
1.4 to 2.7 GHz
80% amplitude
modulated
1 kHz sine wave |
10 V/m 80
MHz–1000 MHz
3 V/m from
1.4 to 2.7 GHz
80% amplitude
modulated
1 kHz sine wave |
Conducted immunity
IEC 60947-4-1,
IEC 61000-4-6 |
140 dub (10V rms)
150 kHz–100 MHz |
140 dub (10V rms)
150 kHz–100 MHz |
140 dub (10V rms)
150 kHz–100 MHz |
Fast transient immunity
IEC 60947-4-1
IEC 61000-4-4 |
±4 kV using direct method
with accessory installed
in expansion bay
±2 kV using direct method |
±4 kV using direct method
with accessory installed
in expansion bay
±2 kV using direct method |
±4 kV using direct method
with accessory installed
in expansion bay
±2 kV using direct method |
Surge immunity
IEC 60947-4-1
IEC 61000-4-5
a Class 4 |
Three-phase power inputs:
±4 kV line-to-line (DM)
±4 kV line-to-ground (CM) |
Three-phase power inputs:
±4 kV line-to-line (DM)
±4 kV line-to-ground (CM) |
Three-phase power inputs:
±4 kV line-to-line (DM)
±4 kV line-to-ground (CM) |
With accessory installed in expansion bay:
±2 kV line-to-line
(DM) –>1.2/50 us;
2 kV line-to-earth,
1 kV line-to-line
±4 kV line-to-ground (CM) |
With accessory installed in expansion bay:
±2 kV line-to-line
(DM) –>1.2/50 us;
2 kV line-to-earth,
1 kV line-to-line
±4 kV line-to-ground (CM) |
With accessory installed in expansion bay:
±2 kV line-to-line
(DM) –>1.2/50 us;
2 kV line-to-earth,
1 kV line-to-line
±4 kV line-to-ground (CM) |
Power freq. magnetic field immunity
IEC 60947-4-1,
IEC 61000-4-8 |
30 A/m, 50 Hz |
30 A/m, 50 Hz |
30 A/m, 50 Hz |
Electromagnetic field
IEC 60947-4-1,
IEC 61000-4-3 |
10 V/m |
10 V/m |
10 V/m |
Distortion IEEE 519 |
5% THD max.,
5th harmonic 3% max. |
5% THD max.,
5th harmonic 3% max. |
5% THD max.,
5th harmonic 3% max. |
Electrostatic discharge (ESD)
IEC 61000-4-2,
EN 61131-2 |
4 kV contact
8 kV air discharge |
4 kV contact
8 kV air discharge |
4 kV contact
8 kV air discharge |
Electrical fast
transient (EFT)
IEC 61000-4-4,
EN 61131-2 |
±2 kV using
direct method |
±2 kV using
direct method |
±2 kV using
direct method |
Surge immunity
IEC 61000-4-5,
EN 61131-2
|
±2 kV
line-to-ground (CM) |
±2 kV
line-to-ground (CM) |
±2 kV
line-to-ground (CM) |