Menu

Eaton AN13KN0A5E
Type CN13/53 Non-Reversing
& Reversing Space-Savings
NEMA Contactors

AN13KN0A5E - Type CN13/53 Space-Savings Three-Pole Non-Reversing and Reversing

Type AN13/53
Space-Savings
Non-Reversing Starter
with XTOE Electronic
Overload Relay


NEMA Size = 3

Continuous Ampere Rating = 90

NOTE: Add Coil Suffix Code (see table below)
For Complete Part Number

Series Part Numbers

NEMA
Size
Continuous
Ampere
Rating
Service
Limit
Current
Rating (Amps)
Maximum
UL Hp
Three-Phase
Standard
MCC
Bucket Size
Three-Pole
Non-
Reversing (1)(2)
Part Number
Three-Pole
Reversing (1)(2)
Part Number
230V 480V
0 18 21 2 5 Not offered AN13BN0A5E_ AN53BN0A5E_
1C 27 32 3 10 Not offered AN13CN0A5E_ AN53CN0A5E_
1 27 32 3 10 1X AN13DN0A5E_ AN53DN0A5E_
2 45 52 7-1/2 25 1X AN13GN0A5E_ AN53GN0A5E_
3 90 104 - 50 2X AN13KN0A5E_ AN53KN0A5E_
4 135 156 - 100 2X AN13NN0A5E_ AN53NN0A5E_
5 (3) 270 311 - 200 6X AN13SN0A5E_ AN53SN0A5E_

XTOE Overload FLA Range
(FVNR and FVR Starters Only) Magnet Coil Suffix

NEMA Size OLR Code FLA Range OLR Code FLA Rating
0    1P6 0.33–1.65A 020 4.0–20A
005 1.0–5.0A
1C/1 1P6(4) 0.33–1.65A 020 4.0–20A
005 1.0–5.0A 045  9.0–45A
2 045 9.0–45A
3 100 20–100A
4 175 35–175A
5(3) 300 60–300A

Coil Suffix Code

Coil Voltage Suffix Code
Sizes 0–2
110V 50 Hz, 120V 60 Hz A
220V 50 Hz, 240V 60 Hz B
24–27 Vdc TD
Sizes 3, 4
100–120V 50/60 Hz A
190–240V 50/60 Hz B
24–27 Vdc TD
Sizes 5
100–120V 50/60 Hz A
24–48 Vdc TD

NOTES:
(1) RED A indicates coils suffix required, see Coil Suffix table above.
(2) Underscore (_) indicates OLR designation required, see XTOE FLA Range table above.
(3) NEMA Size 5 starter available with 60-300A panel mounted CTs. Starter shipped as an assembled unit with 1–5A C440 overload relay (C440A1A005SELAX or C440A2A005SELAX).
(4) Not available on AN13DN or AN53DN starters.

Technical Data and Specifications - Sizes 3, 4

Description Size 3
CN13KN000_
Size 4
CN13MN000_
General
Standards IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS
IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS
Weights in kg [lb]
AC operated  2 [4.41] 2 [4.41]
DC operated 2.1 [4.63] 2.1 [4.63]
Mechanical life—operations 10,000,000 10,000,000
Climatic proofing (1) (1)
Insulation voltage (Ui) Vac  690 690
Impulse withstand voltage (Uimp) Vac  8000 8000
Operational voltage (Ue) Vac 690 690
Safe isolation to VDE 0106 Part 101 and Part 101/A1
Between coil and contacts (Vac) 690 690
Between contacts (Vac)  690 690
Making capacity (amps) 1610  2100
Breaking capacity (amps)
220/230V 1150 1500
380/400V 1150 1500
500V 1150 1500
660/690V 1100 1200
1000V
Short-circuit protection rating maximum fuse
Type 2 coordination (2)
400V; gG/gL 500V
250 25
Type 2 coordination (2)
690V; gG/gL 690V
25 250
Type 1 coordination (2)
400V; gG/gL 500V
250 250
Type 1 coordination (2)
690V; gG/gL 690V
250 250
Degree of protection IP00 IP00
Protection against direct
contact when actuated
from front (IEC 536)
Finger and
back-of-hand proof
Finger and
back-of-hand proof
Terminal capacity main cable—screw terminals
Solid (mm2)
Flexible with ferrule (mm2) 1 x (10–95)
2 x (10–70)
1 x (10–95)
2 x (10–70)
Stranded (mm2) 1 x (10–95)
2 x (10–20)
1 x (10–95)
2 x (10–20)
Flat conductor
(number of segments x width x thickness) (mm)
2 x (6 x 16 x 0.8) 2 x (6 x 16 x 0.8)
Solid or stranded (AWG) 8–3/0 8–3/0
Main cable connection screw/bolt M10 M10
Tightening torque - Nm 14 14
Tightening torque - Lb-in 123.9 123.9
Terminal capacity control circuit cable—screw terminals
Solid (mm2) 1 x (0.75–4)
1 x (0.75–4)
1 x (0.75–4)
1 x (0.75–4)
Flexible with ferrule (mm2) 1 x (0.75–2.5)
2 x (0.75–2.5)
1 x (0.75–2.5)
2 x (0.75–2.5)
Solid or stranded (AWG) 18–14 18–14
Control circuit cable connection screw/bolt M3.5 M3.5
Tightening torque
Nm
1.2 1.2
Tightening torque
Lb-in
10.6 10.6
Tools
Main circuit cable—screw terminals
Hexagon socket-head spanner (mm)
5 5
Control circuit cable—screw terminals Size 2 Size 2
Pozidriv screwdriver 0.8 x 5.5 0.8 x 5.5
Standard screwdriver 1 x 6 1 x 6
Terminal capacity control circuit cable—spring cage terminals
Solid (mm2) 1 x (0.75–2.5)
2 x (0.75–2.5)
1 x (0.75–2.5)
2 x (0.75–2.5)
Flexible (mm2)
1 x (0.75–2.5)
2 x (0.75–2.5)
1 x (0.75–2.5)
2 x (0.75–2.5)
Flexible with ferrule (mm2)
1 x (0.75–2.5)
2 x (0.75–2.5)
1 x (0.75–2.5)
2 x (0.75–2.5)
Control circuit cable—spring cage terminals
Stripping length (mm)
10 10
Screwdriver blade width (mm) 3.5 3.5
Mounting position, AC and DC operated Size 3 - CN13KN000_ Mounting Position Size 4 - CN13MN000_ Mounting Position
Ambient temperature
Open
–25 to 60°C
[–13 to 140°F]
–25 to 60°C
[–13 to 140°F]
Ambient temperature
Enclosed
–25 to 40°C
[–13 to 104°F]
–25 to 40°C
[–13 to 104°F]
Ambient storage temperature
–40 to 80°C
[–40 to 176°F]
–40 to 80°C
[–40 to 176°F]
Environmental - Mechanical shock resistance
(IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms
Main contact—NO contact
10g 10g
Auxiliary contact—NO contact 7g 7g
Auxiliary contact—NC contact 5g 5g
Overvoltage category/pollution degree III/3 III/3

NOTES:
(1) Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60 068-2-30.
(2) IEC 60947 Standard.

Electronic Overload Relays
Up to 1500A
Technical Data and Specifications

Description Specification
45 mm 55 mm 110 mm
Electrical Ratings Range Range  Range
Operating voltage (three-phase)
and frequency 
690 Vac (60/50 Hz) 690 Vac (60/50 Hz) 690 Vac (60/50 Hz)
FLA Range 0.33–1.65A
1–5A
4–20A
9–45A
20–100A 28–140A (NEMA)
35–175A (IEC)
Use with Contactors
Space-Savings NEMA Size
0, 1C 1, 2, 3 4
Trip Class 10A, 10, 20, 30
Selectable
10A, 10, 20, 30
Selectable
10A, 10, 20, 30
Selectable
Motor Protection
Thermal overload setting
1.05 x FLA: does not trip
1.15 x FLA: overload trip
1.05 x FLA: does not trip
1.15 x FLA: overload trip
1.05 x FLA: does not trip
1.15 x FLA: overload trip
Phase loss  Fixed threshold 50% Fixed threshold 50% Fixed threshold 50%
Phase unbalance
(selectable: enable/disable)
Fixed threshold 50% Fixed threshold 50% Fixed threshold 50%
Ground fault
(selectable: enable/disable)
50% of FLA dial setting
>150% = 2 sec
>250% = 1 sec
50% of FLA dial setting
>150% = 2 sec
>250% = 1 sec
50% of FLA dial setting
>150% = 2 sec
>250% = 1 sec
Reset Manual/automatic Manual/automatic Manual/automatic
Trip status Orange flag Orange flag Orange flag
Mode LED One flash:
Overload operating
properly
Two flashes:
Current is above
FLA dial
setting—
pending trip
One flash:
Overload operating
properly
Two flashes:
Current is above
FLA dial
setting—
pending trip
One flash:
Overload operating
properly
Two flashes:
Current is above
FLA dial
setting—
pending trip
Remote reset Yes Yes Yes
Reset bar Yes Yes Yes
Communication
expansion module
Yes Yes Yes
Communication adapter Yes Yes Yes
Load terminals
Terminal capacity
12–10 AWG (4–6 mm2)
8–6 AWG (6–16 mm2)
6–1 AWG (16–50 mm2) 8–4/0 AWG (10–95 mm2)
Load terminals
Tightening torque
20–25 lb-in (2.3–2.8 Nm)
25–30 lb-in (2.8–3.4 Nm)
25–30 lb-in (2.8–3.4 Nm) 124 lb-in (14 Nm)
Input, auxiliary contact
and remote reset terminals
Terminal capacity
2 x (18–12) AWG 2 x (18–12) AWG 2 x (18–12) AWG
Input, auxiliary contact
and remote reset terminals
Tightening torque
7–11 lb-in (0.8–1.2 Nm) 7–11 lb-in (0.8–1.2 Nm) 7–11 lb-in (0.8–1.2 Nm)
Voltages
Insulation voltage Ui
(three-phase)
690 Vac 690 Vac  690 Vac
Insulation
voltage Ui (control)
500 Vac  500 Vac 500 Vac
Rated impulse
withstand voltage
6000 Vac 6000 Vac  6000 Vac
Overvoltage category/
pollution degree
III/3 III/3 III/3
Auxiliary and Control Circuit Ratings
Conventional thermal
continuous current
5A 5A 5A
Rated operational current
—IEC AC-15
Make contact (1800 VA)
 
120V 15A 15A 15A
240V 15A 15A 15A
415V 0.5A 0.5A  0.5A
500V 0.5A 0.5A 0.5A
Break contact (180 VA)  
120V 1.5A 1.5A 1.5A
240V 1.5A 1.5A 1.5A
415V 0.9A 0.9A 0.9A
500V 0.8A 0.8A 0.8A
IEC DC-13 (L/R F 15 ms1)  
0–250V 1.0A 1.0A 1.0A
Rated operational current
UL B600
Make contact (3600 VA)
 
120V 30A 30A 30A
240V 15A 15A 15A
480V 7.5A 7.5A 7.5A
600V 6A 6A 6A
Break contact (360 VA)  
120V 3A 3A 3A
240V 1.5A 1.5A 1.5A
480V 0.75A 0.75A 0.75A
600V 0.6A 0.6A 0.6A
R300—Vdc ratings (28 VA)  
0–120V 0.22A 0.22A 0.22A
250V 0.11A 0.11A 0.11A
Short-Circuit Rating without Welding
Maximum fuse   6A gG/gL 6A gG/gL 6A gG/gL
Environmental Ratings
Ambient temperature
(operating)
–13° to 149°F
(–25° to 65°C)
–13° to 149°F
(–25° to 65°C)
–13° to 149°F
(–25° to 65°C)
Ambient temperature
(storage)
–40° to 185°F
(–40° to 85°C)
 –40° to 185°F
(–40° to 85°C)
–40° to 185°F
(–40° to 85°C)
Operating humidity
UL 991 (H3)
5% to 95%
noncondensing
5% to 95%
noncondensing
5% to 95%
noncondensing
Altitude (no derating)
NEMA ICS1
2000m 2000m 2000m
Shock
(IEC 600068-2-27)
15g any direction 15g any direction 15g any direction
Vibration
(IEC 60068-2-6)
3g any direction 3g any direction 3g any direction
Pollution degree per
IEC 60947-4-1
3 for product (2 for pcb) 3 for product (2 for pcb) 3 for product (2 for pcb)
Ingress protection IP20 IP20 IP20
Protection against direct
contact when actuated from
front (IEC 536)
Finger- and
back-of-hand proof
Finger- and
back-of-hand proof
Finger- and
back-of-hand proof
Mounting position  Any Any Any
Climatic proofing Damp heat,
constant to
IEC 60068-2-30
Damp heat,
constant to
IEC 60068-2-30
Damp heat,
constant to
IEC 60068-2-30
Electrical/EMC
Radiated emissions
IEC 60947-4-1-Table 15
EN 55011 (CISPIR 11)
Group 1, Class A, ISM
30 MHz to
1000 MHz
30 MHz to
1000 MHz
30 MHz to
1000 MHz
Conducted emissions
IEC 60947-4-1-Table 14
EN 55011 (CISPIR 11)
Group 1; Class ISM
0.15 MHz to
30 MHz
0.15 MHz to
30 MHz
 0.15 MHz to
30 MHz
ESD immunity
IEC 60947-4-1
±8 kV air,
±6 kV contact
±8 kV air,
±6 kV contact
±8 kV air,
±6 kV contact
Radiated immunity
IEC 60947-4-1
IEC 61000-4-3
10 V/m 80
MHz–1000 MHz
3 V/m from
1.4 to 2.7 GHz
80% amplitude
modulated
1 kHz sine wave
10 V/m 80
MHz–1000 MHz
3 V/m from
1.4 to 2.7 GHz
80% amplitude
modulated
1 kHz sine wave
10 V/m 80
MHz–1000 MHz
3 V/m from
1.4 to 2.7 GHz
80% amplitude
modulated
1 kHz sine wave
Conducted immunity
IEC 60947-4-1,
IEC 61000-4-6
140 dub (10V rms)
150 kHz–100 MHz
140 dub (10V rms)
150 kHz–100 MHz
140 dub (10V rms)
150 kHz–100 MHz
Fast transient immunity
IEC 60947-4-1
IEC 61000-4-4
±4 kV using direct method
with accessory installed
in expansion bay
±2 kV using direct method
±4 kV using direct method
with accessory installed
in expansion bay
±2 kV using direct method
±4 kV using direct method
with accessory installed
in expansion bay
±2 kV using direct method
Surge immunity
IEC 60947-4-1
IEC 61000-4-5
a Class 4
Three-phase power inputs:
±4 kV line-to-line (DM)
±4 kV line-to-ground (CM)
Three-phase power inputs:
±4 kV line-to-line (DM)
±4 kV line-to-ground (CM)
Three-phase power inputs:
±4 kV line-to-line (DM)
±4 kV line-to-ground (CM)
With accessory installed in expansion bay:
±2 kV line-to-line
(DM) –>1.2/50 us;
2 kV line-to-earth,
1 kV line-to-line
±4 kV line-to-ground (CM)
With accessory installed in expansion bay:
±2 kV line-to-line
(DM) –>1.2/50 us;
2 kV line-to-earth,
1 kV line-to-line
±4 kV line-to-ground (CM)
With accessory installed in expansion bay:
±2 kV line-to-line
(DM) –>1.2/50 us;
2 kV line-to-earth,
1 kV line-to-line
±4 kV line-to-ground (CM)
Power freq. magnetic field immunity
IEC 60947-4-1,
IEC 61000-4-8
30 A/m, 50 Hz 30 A/m, 50 Hz 30 A/m, 50 Hz
Electromagnetic field
IEC 60947-4-1,
 IEC 61000-4-3
10 V/m 10 V/m 10 V/m
Distortion IEEE 519  5% THD max.,
5th harmonic 3% max.
5% THD max.,
5th harmonic 3% max.
5% THD max.,
5th harmonic 3% max.
Electrostatic discharge (ESD)
IEC 61000-4-2,
EN 61131-2
4 kV contact
8 kV air discharge
4 kV contact
8 kV air discharge
4 kV contact
8 kV air discharge
Electrical fast
transient (EFT)
IEC 61000-4-4,
EN 61131-2
±2 kV using
direct method
±2 kV using
direct method
±2 kV using
direct method
Surge immunity
IEC 61000-4-5,
EN 61131-2
±2 kV
line-to-ground (CM)
±2 kV
line-to-ground (CM)
±2 kV
line-to-ground (CM)

NEMA Size 3 Dimensions

AN13KN0A5E Dimensions

Let our expert sales staff guide you through finding the right products to fit your needs. CALL 866-595-9616.