Moeller PKE |
The motor-protective circuit-breaker PKE has versatile, approved accessories available from the xStart range for safe and rational control panel construction. Modular standard components optimally matched to one another and simple to combine fulfil the customer requirements for exchangeable "standard" devices. |
|
System advantages at a glance:Expandable: Flexible solutions for divergent demands
Modular (plug-in): Fast and cost-effective mounting and wiring
International: No problems with export of machines and systems
|
|
Auxiliary Contacts |
Auxiliary Contacts |
Contact Conf. |
Contact Sequence |
Screw Terminal Part Number |
|
---|---|---|---|---|
Moeller | Eaton | |||
Side-Mount Auxiliary Contacts | ||||
1NO-1NC | NHI11-PKZ0 | XTPAXSA11 | ||
1NO-1NC | NHI12-PKZ0 | XTPAXSA12 | ||
2NO-2NC | NHI21-PKZ0 | XTPAXSA21 | ||
Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT) and can be combined with XTPAXSATR_ and XTPAXFA_ trip indicating auxiliary contact. |
||||
Front-Mount Auxiliary Contacts | ||||
1NO-1NC | NHI-E-11-PKZ0 | XTPAXFA11 | ||
Can be fitted to manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT). 45 mm (XTPR…B and XTPB) or 55 mm (XTPR…D) widths of manual motor protectors remain unchanged. |
||||
Side-Mount Trip Indicating Auxiliary Contacts - For Use With XTPE... | ||||
2 x 1NO | AGM2-10-PKZ0 | XTPAXSATR20 | ||
2 x 1NO | AGM2-01-PKZ0 | XTPAXSATR02 | ||
Can be fitted on the right side of manual motor protectors. Can be combined with standard auxiliary contacts. Trip indication: A. General trip indication (overload) B. Short-circuit trip. Local short-circuit indication by red indicator, manually resettable. |
Three-Phase Commoning Links(7) | ||||||
---|---|---|---|---|---|---|
For Use With... |
Qty. MMP |
Length of Link (mm) |
Unit Width (mm) |
Moeller Part Number |
Eaton Part Number |
|
MMP with no side-mounted auxiliaries or voltage releases |
2 | 90 | 45 | B3.0/2-PKZ0 | XTPAXCLKA2 | |
3 | 135 | 45 | B3.0/3-PKZ0 | XTPAXCLKA3 | ||
4 | 180 | 45 | B3.0/4-PKZ0 | XTPAXCLKA4 | ||
5 | 225 | 45 | B3.0/5-PKZ0 | XTPAXCLKA5 | ||
Each MMP with one auxiliary contact or trip-indicating auxiliary contact fitted on the right |
2 | 99 | 45 + 9 | B3.1/2-PKZ0 | XTPAXCLKB2 | |
3 | 153 | 45 + 9 | B3.1/3-PKZ0 | XTPAXCLKB3 | ||
4 | 207 | 45 + 9 | B3.1/4-PKZ0 | XTPAXCLKB4 | ||
5 | 261 | 45 + 9 | B3.1/5-PKZ0 | XTPAXCLKB5 | ||
Each MMP with an auxiliary contact and trip-indicating auxiliary contact mounted on the right or a voltage release mounted on the left. |
2 | 108 | 45 + 18 | B3.2/2-PKZ0 | XTPAXCLKC2 | |
For parallel
power feed to several manual motor protectors on
terminals 1, 3 and 5. |
Door coupling handle — Protection type IP65, UL/CS Type 4X / Type12 | |||||||
---|---|---|---|---|---|---|---|
For use as main switch to IEC/EN 60204 |
black | Plug-in extension shaft PKZ0-XAH can be cut to desired length for mounting depths of 100…240 mm Carrier with extension shaft included in delivery. With ON/OFF switch position and “+” (tripped), lockable with 3 padlocks, 4 – 8 mm hasp. |
PKE-XH | XTPEXRHMB | |||
For use as main switch with Emergency- Stop function to IEC/EN 60204 |
red-yellow | PKE-XRH | XTPEXRHMRY | ||||
For use as a main switch to EN 60204 in MCC power distribution systems and with PKE installed when rotated by 90° |
black | PKE-XH-MCC | XTPEXRHM90B | ||||
For use as a main switch to EN 60204 in MCC power distribution systems and with PKE installed when rotated by 90° |
red-yellow | PKE-XRH-MCC | XTPEXRHM90RY |
Shroud for Unused Terminals of Three-Phase Commoning Links | ||||
---|---|---|---|---|
For Use with… | Description | Moeller Part Number |
Eaton Part Number |
|
Frame B XTPE |
To cover unused terminals on three-phase commoning link. Protected against direct contact. |
H-B3-PKZ0 | XTPAXUTS |
Incoming Terminals for Three-Phase Commoning Link(8) | |||
---|---|---|---|
For Use With... | Moeller Part Number |
Eaton Part Number |
|
Frame B XTPE | BK25/3-PKZ0 | XTPAXIT |
NOTES:
(1) Plug-in connection shafts, XTPAXRHMSFT_ can be cut to desired length for mounting depths of 100–240 mm. Carrier with extension shaft included
(2) With ON/OFF switch position and “+” (tripped), lockable with 3 padlocks, 4–8 mm hasp. Can be locked in the OFF position, if required.
(3) Rotary handle mechanisms ship with door interlock disabled. See instruction publication with product for how to enable door interlock.
(4) Orders must be placed in multiples of package quantity listed.
(5) For use on main switches to IEC/EN 60204.
(6) For use on main switches with emergency-stop function to IEC/EN 60204.
(7) Protected against accidental contact. Frame B short-circuit proof Ue = 690V, Iu = 63A. Frame B links can be combined by rotating mounting.
(8) For three-phase commoning link, protected against accidental contact, Ue = 690V, Iu = 63A; For conductor cross-sections: 2.5–25 mm2 stranded; 2.5–16 mm2 flexible with ferrules, AWG 14-6.
Non-Reversing Starters | ||||
---|---|---|---|---|
For Use With... |
Description/ Comprised of … |
Moeller Part Number |
Eaton Part Number |
|
XTPE…B + XTCE…B |
Mechanical connection element for XTPR…B and contactor |
PKZM0-XDM12 | XTPAXTPCB | |
Main current wiring between XTPR…B and contactor in toolless plug connection |
||||
Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm2 external diameter or four cables up to 3.5 mm2 external diameter. |
||||
XTPR…B + XTCE…C |
DIN rail adapter plate Main current wiring between XTPR and contactor |
PKZM0-XDM32 | XTPAXTPCC | |
Reversing Starters | ||||
XTPE…B + XTCE…B01_ |
Mechanical connection element for XTPR…B and contactor |
PKZM0-XRM12 | XTPAXTPCRB | |
Reversing starter main current wiring in toolless plug connection |
||||
Control cables for electrical interlocking in toolless plug connection: – K1M: A1–K2M: 21 – K1M: 21–K2M: A1 – K1M: A2–K2M: A2 |
||||
Cable guidance | ||||
Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm2 external diameter or four cables up to 3.5 mm2 external diameter. |
||||
Electrical Connection Module | ||||
XTPE…B + XTCE…C |
Main current wiring between XTPR…B and contactor |
PKZM0-XM32DE | XTPAXECMC | |
DIN Rail Adapter Plates | ||||
XTPAXTPCB XTPAXTPCRB |
45 mm wide adapter plate with one DIN rail |
PKZM0-XC45 | XTPAXTPCPB | |
Connection element for side-by-side positioning of further plates |
||||
SmartWire-DT communication link | ||||
XTPE…B + XTCE…B or C |
SmartWire-DT communication link |
PKE-SWD-32 | PKE-SWD-32 |
Incoming terminal | |||||||
---|---|---|---|---|---|---|---|
Incoming terminal | For Use With... |
Description/ Comprised of … |
Moeller | Eaton | |||
For PKE32 use and rated currents exceeding 32 A |
For three-phase commoning link protected against accidental contact Ue = 690 V, Iu = 63 A For conductor cross-sections: 2.5 – 25 mm2 stranded 2.5 – 16 mm2 fl exible with ferrules For use on terminals 2, 4, 6 |
BK25-3- PKZ0-U |
XTPAXOT | ||||
Relay function module | |||||||
For use with PKE advanced trip blocks |
When using PKE-XZMR module an overload does not cause the motor-protection circuit-breaker to trip. The overload indication is produced by means of two auxiliary contacts. |
PKE-XZMR | XTPEXZMRF | ||||
Fixing bracket | |||||||
For screw fixing to mounting plate | PKE32-XMB | XTPEXMBB | |||||
Motor connect plug for motor starter combinations — Motor plate with PE module without contact plate | |||||||
PKZM0/PKE +
DILM(C)7 PKZM0/PKE + DILM(C)9 PKZM0/PKE + DILM(C)12 PKZM0/PKE + DILM(C)15 MSC-D(E)-…-M7… MSC-D(E)-…-M9… MSC-D(E)-…-M12… MSC-D(E)-…-M15… |
DILM12-XMCP/T | XTCEXMCPTB |