A-PKZ0 shown |
XTPAXSR48V50H Shunt Release |
||||
Description | Actuating Voltage |
For Use With | Old Moeller Part Number |
New Eaton Part Number |
---|---|---|---|---|
Shunt Release | 48 V 50 Hz | PKZM0 PKZM4 PKZM0-T PKM0 PKZM01 PKE |
A-PKZ0(48V50HZ) | XTPAXSR48V50H |
XTPAXSR48V50H Technical Data |
|
General | |
---|---|
Moeller Part No. | A-PKZ0(48V50HZ) |
Eaton Part No. | XTPAXSR24V50H |
Delivery program | |
Product range | Accessories |
Accessories | Shunt release |
Actuating voltage | 48 V 50 Hz |
For use with | Shunt release PKZ0(4), PKE |
Voltage type | Standard voltage |
Current actuation | AC |
Connection technique | Screw terminals |
For use with | PKZM0 PKZM4 PKZM0-T PKM0 PKZM01 PKE |
For PKE, only A-PKZ0 or U-PKZ0... with a serial number of 02 or higher can be retrofitted. |
|
Notes: Can be fitted to the left of: Motor-protective circuit-breakers Cannot be combined with: U-PKZ0 undervoltage release DC: Intermittent operation 5 s |
|
Technical data | |
General | |
Terminal capacities | |
Solid or flexible conductor, with ferrule (mm2) |
1 x (0,75 - 2,5) 2 x (0,75 - 2,5) |
Solid or stranded (AWG) | 1 x (18 - 14) 2 x (18 - 14) |
Actuating voltage | 48 V 50 Hz |
Operating range | |
Alternating voltage | 0.7- 1.1 (x US) |
DC Voltage (x US) | 0.7- 1.1 (x US) |
Power consumption | |
Pull-in power (Pick-up) | 5 VAC |
Sealing power (Sealing) | 3 VAC |
Design verification as per IEC/EN 61439 | |
Technical data for design verification | |
Static heat dissipation, non-current-dependent (Pvs) | 0.5 W |
Heat dissipation capacity (Pdiss) | 0 W |
IEC/EN 61439 design verification | |
10.2 Strength of materials and parts | |
10.2.2 Corrosion resistance | Meets the product standard's requirements. |
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements. |
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements. |
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard's requirements. |
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.7 Inscriptions | Meets the product standard's requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard's requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility. |
10.8 Connections for external conductors | Is the panel builder's responsibility. |
10.9 Insulation properties | |
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Technical data ETIM 5.0 | |
Low-voltage industrial components (EG000017) / Shunt release (for power circuit breaker) (EC001023) |
|
Electric engineering, automation,
process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Full load current trip (ecl@ss8-27-37-04-18 [AKF016009]) |
|
Rated control supply voltage Us at AC 50HZ | 24 - 24 V |
Rated control supply voltage Us at AC 60HZ | 0 - 0 V |
Rated control supply voltage Us at DC | 0 - 0 V |
Voltage type for actuating | AC |
Initial value of the undelayed short-circuit release - setting range |
0 V |
End value adjustment range undelayed short-circuit release |
0 V |
Type of electric connection | Screw connection |
Number of contacts as normally open contact | 0 |
Number of contacts as normally closed contact | 0 |
Number of contacts as change-over contact | 0 |
Suitable for power circuit breaker | No |
Suitable for switch disconnector | No |
Suitable for motor safety switch | Yes |
Suitable for overload relay | No |
Approvals | |
Product Standards | UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking |
UL File No. | E36332 |
UL Category Control No. | NLRV |
CSA File No. | 165628 |
CSA Class No. | 3211-05 |
North America Certification | UL listed, CSA certified |
Specially designed for North America | No |
XTPAXSR48V50H Dimensions |
||