Eaton |
XTPAXUTS shown |
XTPAXUTS Shroud for Unused Terminal |
|||
Description | For Use With | Old Moeller Part Number |
New Eaton Part Number |
---|---|---|---|
Shroud for unused terminals |
For covering unused terminals on three-phase commoning link B3...-PKZ0. |
H-B3-PKZ0 | XTPAXUTS |
XTPAXUTS Shroud for Unused Terminal Technical Data |
|
Product range | Accessories |
Accessories | Shroud for unused terminals |
Protection against direct contact. For covering unused terminals on three-phase commoning link B3...-PKZ0 |
|
Design verification as per IEC/EN 61439 | |
---|---|
Technical data for design verification | |
Rated operational current for specified heat dissipation (In) |
0 A |
Heat dissipation per pole, current-dependent (Pvid) | 0 W |
Equipment heat dissipation, current-dependent (Pvid) | 0 W |
Static heat dissipation, non-current-dependent (Pvs) | 0 W |
Heat dissipation capacity (Pdiss) | 0 W |
IEC/EN 61439 design verification | |
10.2 Strength of materials and parts | |
10.2.2 Corrosion resistance | Meets the product standard's requirements. |
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements. |
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements. |
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard's requirements. |
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements. |
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.7 Inscriptions | Meets the product standard's requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard's requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
10.8 Connections for external conductors | Is the panel builder's responsibility. |
10.9 Insulation properties | |
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility. |
10.10 Temperature rise | Not applicable. |
10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Technical data ETIM 5.0 | |
Low-voltage industrial components (EG000017) / Accessories for low-voltage switch technology (EC002498) |
|
Electric engineering, automation, process control engineering / Low-voltage switch technology / Low-voltage switch technology (accessories) / Component for low-voltage switch technology (accessories) (ecl@ss8-27-37-92-01 [AKN570009]) |
|
Type of accessory | Cover |
Approvals | |
Product Standards | UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking |
UL File No. | E36332 |
UL Category Control No. | NLRV |
CSA File No. | 98494 |
CSA Class No. | 3211-06 |
North America Certification | UL listed, CSA certified |