EATON Freedom Series NEMA Contactors & Electric Motor Starters
Freedom Series Heater Packs
Heater packs H2001B to H2017B and H2101B to H2117B are to be used only with Series B overload relays Catalog Numbers C306DN3B (Part No. 10-7016) and C306GN3B (Part No. 10-7020). The load lugs are built into the overload relay base to allow load wiring prior to heater pack installation. The previous heater design had integral load lugs. The Series B heater packs are electrically equivalent to the previous heater design. Heaters H2018-3 to H2024-3 have not changed.
Starters with Series B Overload Relays (1)
NEMA-AN Type Size |
Series |
IEC-AE Type Size |
Series |
00-0 |
C |
A-F |
C |
1-2 |
B |
G-K |
B |
5 |
B |
G-K |
B |
6 |
C |
G-K |
B |
7-8 |
B |
G-K |
B |
Standard Trip—Class 20 Heater
Heater Pack H2001B–H2017B
Heater Pack H2018–H2024
For Use with NEMA Sizes 00-0 Series C, NEMA Sizes 1-2 Series B; IEC Sizes A-F Series C, IEC Sizes G-K Series B |
Overload Relay Size |
Motor Full Load Ampere Rating Dial Position |
Part Number (2) |
A |
B |
C |
D |
105A or 144A |
0.254 |
0.306 |
0.359 |
0.411 |
H2001B-3 |
0.375 |
0.452 |
0.53 |
0.607 |
H2002B-3 |
0.56 |
0.676 |
0.791 |
0.907 |
H2003B-3 |
0.814 |
0.983 |
1.15 |
1.32 |
H2004B-3 |
1.2 |
1.45 |
1.71 |
1.96 |
H2005B-3 |
1.79 |
2.16 |
2.53 |
2.9 |
H2006B-3 |
2.15 |
2.6 |
3.04 |
3.49 |
H2007B-3 |
3.23 |
3.9 |
4.56 |
5.23 |
H2008B-3 |
4.55 |
5.5 |
6.45 |
7.4 |
H2009B-3 |
6.75 |
8.17 |
9.58 |
11 |
H2010B-3 |
9.14 |
10.8 |
12.4 |
14 |
H2011B-3 |
14 |
16.9 |
19.9 |
22.8 |
H2012B-3 |
18.7 |
22.7 |
26.7 |
30.7 |
H2013B-3 |
23.5 |
28.5 |
33.5 |
38.5 |
H2014B-3 |
For Use with NEMA Size 2, IEC Sizes G-K Only, Series B |
75A |
29 |
34 |
39.1 |
44.1 |
H2015B-3 |
39.6 |
45.5 |
51.5 |
57.4 |
H2016B-3 |
53.9 |
60.9 |
67.9 |
74.9 |
H2017B-3 |
For Use with NEMA Sizes 3-4, IEC Sizes L-N Only-Series A |
105A or 144A |
8.0 |
9.2 |
10.3 |
11.5 |
H2025-3 |
11.4 |
12.8 |
14.3 |
15.7 |
H2026-3 |
14.3 |
15.7 |
17.4 |
19.0 |
H2027-3 |
18.0 |
20.2 |
22.3 |
24.5 |
H2018-3 |
24.6 |
27.6 |
30.5 |
33.4 |
H2019-3 |
33.5 |
37.5 |
41.5 |
45.6 |
H2020-3 |
45.7 |
51.2 |
56.7 |
62.1 |
H2021-3 |
62.2 |
69.7 |
77.1 |
84.6 |
H2022-3 |
84.7 |
95.0 |
105.0 |
115.0 |
H2023-3 |
106.0 |
118.0 |
131.0 |
144.0 |
H2024-3 |
For Use with Size 5 Starters-Series B and IEC P, R and S with 300/5 CT |
32A (2) |
49 |
59 |
69 |
79 |
H2004B-3 |
72 |
87 |
103 |
118 |
H2005B-3 |
107 |
130 |
152 |
174 |
H2006B-3 |
129 |
156 |
182 |
209 |
H2007B-3 |
194 |
234 |
274 |
~ |
H2008B-3 |
For Use with Size 6 Starters Only-Series B and IEC T-V with 600/5 CT |
32A (2) |
144 |
174 |
205 |
235 |
H2005B-3 |
215 |
259 |
304 |
348 |
H2006B-3 |
258 |
312 |
365 |
419 |
H2007B-3 |
388 |
468 |
547 |
627 |
H2008B-3 |
For Use with Size 7 Starters Only-Series B and IEC W-X with 1000/5 CT |
32A (2) |
163 |
197 |
230 |
264 |
H2004B-3 |
240 |
290 |
342 |
392 |
H2005B-3 |
358 |
432 |
506 |
580 |
H2006B-3 |
430 |
520 |
608 |
698 |
H2007B-3 |
646 |
780 |
912 |
~ |
H2008B-3 |
For Use Size 8 Starters Only-Series B and IEC Z with 1500/5 CT |
32A (2) |
244 |
295 |
345 |
396 |
H2004B-3 |
360 |
435 |
513 |
588 |
H2005B-3 |
537 |
648 |
759 |
870 |
H2006B-3 |
645 |
780 |
912 |
1047 |
H2007B-3 |
696 |
1170 |
1368 |
~ |
H2008B-3 |
Notes
(1) The series of a starter is the last digit of the listed catalog number. Example: AN16DN0AB.
(2) Heater packs are shipped three to a carton. catalog numbers are for three heater packs.
Fast Trip—Class 10 Heater
Heater Pack
H2101B-H2117B
For Use with NEMA Sizes 00–0 Series C, NEMA Sizes 1–2 Series B; IEC Sizes A–F Series C, IEC Sizes G–K Series B |
Overload Relay Size |
Motor Full Load Ampere Rating Dial Position |
Part Number (2) |
A |
B |
C |
D |
32A or 75A |
0.26 |
0.313 |
0.367 |
0.42 |
H2101B-3 |
0.384 |
0.464 |
0.543 |
0.623 |
H2102B-3 |
0.57 |
0.688 |
0.806 |
0.924 |
H2103B-3 |
0.846 |
1.02 |
1.2 |
1.37 |
H2104B-3 |
1.28 |
1.55 |
1.83 |
2.1 |
H2105B-3 |
1.92 |
2.33 |
2.74 |
3.15 |
H2106B-3 |
2.3 |
2.79 |
3.28 |
3.77 |
H2107B-3 |
3.38 |
4.1 |
4.82 |
5.54 |
H2108B-3 |
4.96 |
6.03 |
7.09 |
8.16 |
H2109B-3 |
7.07 |
8.58 |
10.1 |
11.6 |
H2110B-3 |
9.6 |
11.2 |
12.8 |
14.4 |
H2111B-3 |
14.4 |
17.5 |
20.7 |
23.8 |
H2112B-3 |
18.7 |
21.8 |
25 |
28.1 |
H2113B-3 |
23.5 |
27.3 |
31 |
34.8 |
H2114B-3 |
For Use with Size 2, IEC Sizes G-K Only-Series B |
75A |
28.3 |
32.6 |
37 |
41.3 |
H2115B-3 |
36.6 |
42.3 |
48.1 |
53.8 |
H2116B-3 |
53.8 |
60.8 |
67.9 |
74.9 |
H2117B-3 |
For Use with Size 5 Starters Only-Series B and IEC P, R and S with 300/5 CT |
32A (2) |
51 |
61 |
72 |
82 |
H2104B-3 |
77 |
93 |
110 |
126 |
H2105B-3 |
115 |
140 |
164 |
189 |
H2106B-3 |
138 |
167 |
197 |
226 |
H2107B-3 |
203 |
246 |
289 |
~ |
H2108B-3 |
For Use with Size 6 Starters Only-Series B and IEC T-V with 600/5 CT |
32A (2) |
154 |
186 |
220 |
252 |
H2105B-3 |
230 |
280 |
329 |
378 |
H2106B-3 |
276 |
335 |
394 |
452 |
H2107B-3 |
406 |
492 |
578 |
~ |
H2108B-3 |
For Use with Size 7 Starters Only-Series B and IEC W-X with 1000/5 CT |
32A (2) |
169 |
204 |
240 |
274 |
H2104B-3 |
256 |
310 |
366 |
420 |
H2105B-3 |
384 |
466 |
543 |
630 |
H2106B-3 |
460 |
558 |
656 |
754 |
H2107B-3 |
676 |
820 |
~ |
~ |
H2108B-3 |
For Use with Size 8 Starters Only-Series B and IEC Z with 1500/5 CT |
32A (2) |
254 |
306 |
360 |
411 |
H2104B-3 |
384 |
465 |
549 |
630 |
H2105B-3 |
576 |
699 |
822 |
945 |
H2106B-3 |
690 |
837 |
984 |
1131 |
H2107B-3 |
1014 |
1230 |
~ |
~ |
H2108B-3 |
Notes
(1) Heater packs are shipped three to a carton. catalog numbers are for three heater packs.