Menu

Eaton A200 Series - NEMA Contactors, Starters, Relays & Shoe Breakes

Eaton Freedom Series Family Photo

A200 series Renewal Parts

When Oredering Specify

Use this renewal parts data to identify device by style number, catalog number and/or description. For clarification of ordering procedure, pricing and discounts, contact the Customer Support Center.

General Information

This renewal parts data will provide the proper identification of standard parts which may be required for maintenance of Eaton’s components. It is the intent of this catalog section to make it possible to quickly select the parts needed. An investment in renewal parts and regular maintenance program will protect against downtime and ensure a proper duty cycle for your equipment. To maintain maximum operating efficiency and dependability of your equipment, only genuine Eaton replacement parts should be used. This section identifies the replacements parts which are available. Order by style number.

JF Autostarter Kits (1)

Frame Size Start Contacts Run Contacts Grid Stack Kit
Required Style Number Required Style Number Required Style Number
2–3 1 38A7018G12 1 38A7018G13 1 3354D90G10
4–5 5L 1 550D409G18 1 38A7018G13 1 3354D90G10
5M–5MM 1 3354D90G08 1 38A7018G13 2 3354D90G10

Solenoid Assembly with Coil (All Sizes) (2)

Volt Hz Style Number (3)
115 60 5264C05H01
230 60 5264C05H02
460 60 5264C05H03
575 60 5264C05H04

Notes:

1 Kits contain a complete set of moving contacts, stationary contacts and springs.
(2) When replacing solenoid assembly series 416C160 use adapter plate style 9917D02H01—one required.
(3) These styles replace coil style 296B892G__. When ordering new style as replacement,customer must order adapter plate 9917D02H01, one required.

AC Contactors Model J Sizes 00, 0, 1, 2 Kits (1)

Part Poles Size 00
Style Number
Size 0
Style Number
Size 1
Style Number
Size 2
Style Number
Contact kit 2 373B331G17 373B331G02 373B331G07 373B331G11
3 373B331G18 373B331G04 373B331G09 373B331G12
4 373B331G18 373B331G04 373B331G09 373B331G13 (3)
5 373B331G19 373B331G05 373B331G10 -
Arc box (2) 2, 3, 4 6714C74G01 6714C74G02 6714C74G03 6714C74G07 (4)
5 6714C74G04 6714C74G05 6714C74G06 6714C74G08 (5)
Cross bar 2, 3 NA NA NA 672B788G32
4, 5 NA NA NA 672B788G34
Upper base (for single rated coils only) 2, 3 NA NA NA 672B788G33
4, 5 NA NA NA 672B788G35
Lower base 2, 3 NA NA NA 1250C33G09
4, 5 NA NA NA 1250C33G05
KO spring (package of 10) All NA NA NA 503C796G01
Terminal line/load (package of 3) All NA NA NA 371B870G03

AC Coils

Voltage Hz Size 00, 0, 1
Two-,Three-, Four Pole
Style Number
Five-Pole
Style Number
Size 2
Two-, Three-Pole
Style Number
Four-, Five-Pole
Style Number
120/110 60/50 505C806G01 505C808G01 505C806G01 505C818G01
208 60 505C806G02 505C808G02 505C806G02 505C818G02
600/550 60/50 505C806G05 505C808G05 505C806G05 505C818G05
380 50 505C806G07 505C808G07 505C806G07 505C818G07
240/220 60/50 505C806G12 505C808G12 505C806G12 505C818G12
480/440 60/50 505C806G13 505C808G13 505C806G13 505C818G13
24 60 505C806G16 N/A 505C806G16 505C818G15
277 60 505C806G18 505C808G16 505C806G18 505C818G16
240.480 (6) 60/60 505C806G03 505C808G03 505C806G03 505C818G03
120/240 (7) 60/60 505C806G10 505C808G10 505C806G10 505C818G10

DC Coil (7)

Voltage Size 0, 1
Single-, Two-, Three-, Four Pole
Style Number
Size 2
Single-, Two-, Three-Pole
Style Num,ber
12 1268C86G07 1268C86G07
24 1268C86G04 1268C86G04
48 1268C86G05 1268C86G05
125 1268C86G02 1268C86G02
250 1268C86G01 1268C86G01
125/250 (6) 1268C86G03 1268C86G03

Notes:

1 Model C contact tips and coils 00-4, two-, three-, four- and five-pole contactors are same as Model J. All other parts are unavailable.
(2) Mounting hardware included.
(3) Use one each of 373B331G11 and 373B331G12.
(4) Two-, three-pole.
(5) Four-, five-pole.
(6) Dual voltage coils. Use only on contactors or starters originally supplied with a dual voltage coil.
(7) Use only on contactors originally supplied with a DC coil.


Accessories for Size 5–9 AC Contactors

A rectifier circuit converts the AC supply to DC supply.
This conversion provides pick up and drop out characteristics. All necessary parts are included in the kit.

AC-DC Coil Conversion Kits

Voltage Size 5
Style Number
Size 6
Style Number
120 Vac 7864A28G01 7864A29G01
240 Vac 7864A28G02 7864A29G02
480 Vac 7864A28G03 7864A29G03

Replacement Coils for AC-DC Coil Conversion Kit

Voltage Size 5
Style Number
Size 6
Style Number
120 Vac 7856A15G05 7856A16G05
240 Vac 7856A15G10 7856A16G10
480 Vac 7856A15G15 7856A16G15

Auxiliary Electrical Interlocks Size 7–9 AC and All DC Units

Type Circuits Application Style Number
L63 NO Size 7-8 578D461G01
L63 NC Size 7-8 578D461G03
L64 NO-NC Size 9 843D943G04
L64 2NO Size 9 843D943G05
L64 2NC Size 9 843D943G06

Accessories for Size 00–6 AC Contactors - Auxiliary Electrical Interlocks

Catalog
Number
(Obsolete)
Style
Number
(Obsolete)
Circuits Part
Number
Current
Style
Number
Current
(L-56) (2609D01G01) 1NO and 1NC J11 9084A17G01
(L-56D) (2609D01G02) 2NO J20 9084A17G02
(L-56E) (2609D01G03) 1NO and 1NC J11 9084A17G01
(L-56B) (2609D01G04) 2NO J20 9084A17G02
(L-56H) (2609D01G05) 2NO J20 9084A17G02
(L-56J) (2609D01G06) 1NO and1NC DB J1C 9084A17G04
(L-56A) (2609D01G07) N/A N/A N/A
(L-56B) (2609D01G08) N/A N/A N/A
(L-56F) (2609D01G09) N/A N/A N/A
(L-56G) (2609D01G10) 1NO and 1NC DB J1C 9084A17G04
(L-56C) (2609D01G11) 2NC J02 9084A17G03
(L-56M) (2609D01G12) N/A N/A N/A
(L-56P) (2609D01G17) 1NO and 1NC J11 9084A17G01
(L-56R) (2609D01G18) 2NC J02 9084A17G03
(L-56S) (2609D01G19) 1NO and 1NC J11 9084A17G01

Model J–K, Sizes 3 and 4 Kits (1)

Part Poles Size 3-Model J
Style Number
Size 4-Model J (2)
Style Number
Size 4-Model K (3)
Style Number
Contact Kit 2 626B187G12 626B187G16 5250C81G16
3 626B187G13 626B187G17 5250C81G17
4 (4) (6) 5250C81G18
5 (5) (7) 5250C81G19
Arc Box 2, 3 6714C74G09 6714C74G11 6714C74G11
4, 5 6714C74G10 6714C74G12 6714C74G12
Cross Bar 2, 3 672B788G36 672B788G36 672B788G40
4, 5 672B788G38 672B788G38 -
Upper Base 2, 3 672B788G37 672B788G37 672B788G52
4, 5 672B788G39 672B788G39 -
Lower Base 2, 3 1250C33G03 1250C33G03 1250C33G10
4, 5 1250C33G06 1250C33G06 -
KO spring (package of 10) All 503C796G02 503C796G02 672B788G50
Terminal line/load (package of 3) All 372B357G12 372B357G18 372B357G18

Notes:

(1) Model C contact tips and coils 00-4, two-, three-, four- and five-pole contactors are same as Model J. All other parts are unavailable.
(2) For 200A A202 magnetically latched lighting contactors order three-pole contact kit style 672B788G07.
(3 Model K replaces Model J, offering superior design life characteristics. Renewal parts are different. Use parts for proper model only.
(4) Use quantity two of 626B187G12.
(5) Use quantity one each of 626B187G12 and 626B187G13.
(6) Use quantity two of 626B187G16.
(7) Use quantity one each of 626B187G16 and 626B187G17.

Accessories for Model J–K, Series 3, 4

DC Coils 1

Voltage Model J Size 3, 4 Two-, Three-Pole Style Number
24 1255C68G04
48 1255C68G05
125 1255C68G01
250 1255C68G02
125/250 (2) 1255C68G03

AC Coils

Voltage Hz Model J Size 3, 4
Two-, Three-Pole
Style NUmber
Four-, Five-Pole
Style Number
Model K Size 4 (3)
Two-, Three-Pole
Style Number
Four-, Five-Pole
Style Number
120/110 60/50 505C633G01 505C635G01 5250C79G01 5250C80G01
208 60 505C633G02 505C635G02 5250C79G02 5250C80G02
600/550 60/50 505C633G05 505C635G05 5250C79G05 5250C80G05
380 50 505C633G07 505C635G07 5250C79G07 5250C80G07
240/220 60/50 505C633G12 505C635G12 5250C79G12 5250C80G12
480/440 60/50 505C633G13 505C635G13 5250C79G13 5250C80G13
24 60 505C633G34 N/A 5250C79G34 N/A
277 60 505C633G14 N/A 5250C79G14 N/A
240/480 (2) 60/60 505C633G03 505C635G03 5250C79G03 5250C80G03
120/244 (2) 60/60 505C633G10 505C635G10 5250C79G10 5250C80G10

A201 Contactors—Size 5–9 / GCA 530/630—GPD 7, 8, 9 Kits (4)

Part Size 5
Style Number
Size 6
Style Number
Size 7
Style Number
Size 8
Style Number
Size 9
Style Number
Contact kit (one per pole) 477B477G05 (5) 2066A10G11 461A757G17 646C829G05 5264C42G01 (6)
5264C42G02 (7)
Arc box 2050A15G45 2066A10G45 831D580G01 831D580G01 9917D69G02
Magnet assembly 2050A15G46 2050A15G46 N/A N/A N/A
Mag. spg. kit 2050A15G47 2050A15G47 N/A N/A N/A
Acr cup kit 2050A15G48 N/A N/A N/A N/A
Load conversion kit 2050A15G49 2066A10G49 N/A N/A N/A
Line conversion kit 2050A15G50 2066A10G50 N/A N/A N/A
K.O. spring–6 2050A15G51 2066A10G46 N/A N/A N/A
C.T. 300/5 655C285H03 N/A N/A N/A N/A
C.T. 400/5 655C285H04 N/A N/A N/A N/A
C.T. 600/5 (8) N/A 2066A10G18 N/A N/A N/A
C.T. 800/5 (8) N/A 2066A10G19 N/A N/A N/A
Phase barrier N/A N/A 640C441G01 640C441G01 5264C35G03 (6)
Cross bar 2050A15G12 2066A10G15 N/A N/A N/A
Shunt N/A 2066A10G48 650C129G01 646C831G02 (9) 5264C39G02 (10)

Notes:

(1) Use only on units originally supplied with DC coil.
(2) Dual voltage coils. Use only on contactors or starters originally supplied with dual voltage coil.
(3) Model K replaces Model J, offering superior design life characteristics. Renewal parts are different. Use parts for proper model only.
(4) Catalog Number A201/A200 Series replaces GCA/GPD series. Renewal parts are the same.
(5) Use 477B477G06 for silver tungsten applications.
6 R.C.

(7) F.C.
(8) C.T. kit which replaces the single molded 1 C.T. assembly used on the old size 6 airbreak. The kit includes a single molded 3 C.T. assembly, 2 bus bar and hardware. This C.T. kit also replaces the single molded 3 C.T. assembly used on the present size 6 airbreak and size vacuum.
(9) Set of three.
(10) Set of four.

Accessories for A201 Contactors - Coils (Sizes 5 and 6)

Voltage Hz Size 5
Style Number
Size 6
Style Number
110/120 60 2050A14G05 2050A12G05
110/120 50 2050A14G06 2050A12G06
200/208 50 2050A14G07 2050A12G07
220/240 50 2050A14G08 2050A12G08
200/208 60 2050A14G09 2050A12G09
220/240 60 2050A14G10 2050A12G10
277/303 60 2050A14G12 2050A14G12
380/415 50 2050A14G14 2050A12G14
440/480 60 2050A14G15 2050A12G15
440/480 50 2050A14G16 2050A12G16
550/600  60 2050A14G17 2050A12G17
550/600 50 2050A14G18 2050A12G18
380/415 60 2050A14G19 2050A12G19
120/240 60 2050A14G20 2050A12G20
24 DC - 2050A14G21 2050A12G21
48 DC - 2050A14G22 2050A12G22
125 DC - 2050A14G25 2050A12G25
250 DC - 2050A14G27 2050A12G27

Accessories for A201 Contactors - Coils (Sizes 7 - 9)

Line Voltage Style Number Required
Sizes 7 and 8
125 Vdc 438C805G04 2
230 Vdc 438C805G02 2
250 Vdc 438C805G03 2
110/120 Vac (1)(4) 438C805G12 2
220/240 Vac (2)(4) 438C805G11 2
380 Vac (3)(4) 438C805G15 2
440/480 Vac (3)(4) 438C805G10 2
440/480 Vac (3)(4) 438C805G13 2
Size 9
110 Vdc 5264C34G01 (5) -

Notes:

(1) Rectifier 125V 2018A40G01 (one required).
(2) Rectifier 250V 2018A40G02 (one required).
(3) Rectifier 600V 2018A40G03 (one required).
(4) These coils require an external rectifier. If the rectifier needs replacement, order by the appropriate style number.
(5) Contains coil and resistor.

Let our expert sales staff guide you through finding the right products to fit your needs. CALL 866-595-9616.