Eaton A200 Series - NEMA Contactors, Starters, Relays & Shoe Breakes
A200 series Renewal Parts
When Oredering Specify
Use this renewal parts data to identify device by style number, catalog number and/or description. For clarification of ordering procedure, pricing and discounts, contact the Customer Support Center.
General Information
This renewal parts data will provide the proper identification of standard parts which may be required for maintenance of Eaton’s components. It is the intent of this catalog section to make it possible to quickly select the parts needed. An investment in renewal parts and regular maintenance program will protect against downtime and ensure a proper duty cycle for your equipment. To maintain maximum operating efficiency and dependability of your equipment, only genuine Eaton replacement parts should be used. This section identifies the replacements parts which are available. Order by style number.
JF Autostarter Kits (1)
Frame Size | Start Contacts | Run Contacts | Grid Stack Kit | |||
Required | Style Number | Required | Style Number | Required | Style Number | |
2–3 | 1 | 38A7018G12 | 1 | 38A7018G13 | 1 | 3354D90G10 |
4–5 5L | 1 | 550D409G18 | 1 | 38A7018G13 | 1 | 3354D90G10 |
5M–5MM | 1 | 3354D90G08 | 1 | 38A7018G13 | 2 | 3354D90G10 |
Solenoid Assembly with Coil (All Sizes) (2)
Volt | Hz | Style Number (3) |
115 | 60 | 5264C05H01 |
230 | 60 | 5264C05H02 |
460 | 60 | 5264C05H03 |
575 | 60 | 5264C05H04 |
Notes:
1 Kits contain a complete set of moving contacts, stationary contacts and springs.
(2) When replacing solenoid assembly series 416C160 use adapter plate style 9917D02H01—one required.
(3) These styles replace coil style 296B892G__. When ordering new style as replacement,customer must order adapter plate 9917D02H01, one required.
AC Contactors Model J Sizes 00, 0, 1, 2 Kits (1)
Part | Poles | Size 00 Style Number |
Size 0 Style Number |
Size 1 Style Number |
Size 2 Style Number |
Contact kit | 2 | 373B331G17 | 373B331G02 | 373B331G07 | 373B331G11 |
3 | 373B331G18 | 373B331G04 | 373B331G09 | 373B331G12 | |
4 | 373B331G18 | 373B331G04 | 373B331G09 | 373B331G13 (3) | |
5 | 373B331G19 | 373B331G05 | 373B331G10 | - | |
Arc box (2) | 2, 3, 4 | 6714C74G01 | 6714C74G02 | 6714C74G03 | 6714C74G07 (4) |
5 | 6714C74G04 | 6714C74G05 | 6714C74G06 | 6714C74G08 (5) | |
Cross bar | 2, 3 | NA | NA | NA | 672B788G32 |
4, 5 | NA | NA | NA | 672B788G34 | |
Upper base (for single rated coils only) | 2, 3 | NA | NA | NA | 672B788G33 |
4, 5 | NA | NA | NA | 672B788G35 | |
Lower base | 2, 3 | NA | NA | NA | 1250C33G09 |
4, 5 | NA | NA | NA | 1250C33G05 | |
KO spring (package of 10) | All | NA | NA | NA | 503C796G01 |
Terminal line/load (package of 3) | All | NA | NA | NA | 371B870G03 |
AC Coils
Voltage | Hz | Size 00, 0, 1 Two-,Three-, Four Pole Style Number |
Five-Pole Style Number |
Size 2 Two-, Three-Pole Style Number |
Four-, Five-Pole Style Number |
120/110 | 60/50 | 505C806G01 | 505C808G01 | 505C806G01 | 505C818G01 |
208 | 60 | 505C806G02 | 505C808G02 | 505C806G02 | 505C818G02 |
600/550 | 60/50 | 505C806G05 | 505C808G05 | 505C806G05 | 505C818G05 |
380 | 50 | 505C806G07 | 505C808G07 | 505C806G07 | 505C818G07 |
240/220 | 60/50 | 505C806G12 | 505C808G12 | 505C806G12 | 505C818G12 |
480/440 | 60/50 | 505C806G13 | 505C808G13 | 505C806G13 | 505C818G13 |
24 | 60 | 505C806G16 | N/A | 505C806G16 | 505C818G15 |
277 | 60 | 505C806G18 | 505C808G16 | 505C806G18 | 505C818G16 |
240.480 (6) | 60/60 | 505C806G03 | 505C808G03 | 505C806G03 | 505C818G03 |
120/240 (7) | 60/60 | 505C806G10 | 505C808G10 | 505C806G10 | 505C818G10 |
DC Coil (7)
Voltage | Size 0, 1 Single-, Two-, Three-, Four Pole Style Number |
Size 2 Single-, Two-, Three-Pole Style Num,ber |
12 | 1268C86G07 | 1268C86G07 |
24 | 1268C86G04 | 1268C86G04 |
48 | 1268C86G05 | 1268C86G05 |
125 | 1268C86G02 | 1268C86G02 |
250 | 1268C86G01 | 1268C86G01 |
125/250 (6) | 1268C86G03 | 1268C86G03 |
Notes:
1 Model C contact tips and coils 00-4, two-, three-, four- and five-pole contactors are same as
Model J. All other parts are unavailable.
(2) Mounting hardware included.
(3) Use one each of 373B331G11 and 373B331G12.
(4) Two-, three-pole.
(5) Four-, five-pole.
(6) Dual voltage coils. Use only on contactors or starters originally supplied with a dual
voltage coil.
(7) Use only on contactors originally supplied with a DC coil.
Accessories for Size 5–9 AC Contactors
A rectifier circuit converts the AC supply to DC supply.
This conversion provides pick up and drop out characteristics. All necessary parts are included in the kit.
AC-DC Coil Conversion Kits
Voltage | Size 5 Style Number |
Size 6 Style Number |
120 Vac | 7864A28G01 | 7864A29G01 |
240 Vac | 7864A28G02 | 7864A29G02 |
480 Vac | 7864A28G03 | 7864A29G03 |
Replacement Coils for AC-DC Coil Conversion Kit
Voltage | Size 5 Style Number |
Size 6 Style Number |
120 Vac | 7856A15G05 | 7856A16G05 |
240 Vac | 7856A15G10 | 7856A16G10 |
480 Vac | 7856A15G15 | 7856A16G15 |
Auxiliary Electrical Interlocks Size 7–9 AC and All DC Units
Type | Circuits | Application | Style Number |
L63 | NO | Size 7-8 | 578D461G01 |
L63 | NC | Size 7-8 | 578D461G03 |
L64 | NO-NC | Size 9 | 843D943G04 |
L64 | 2NO | Size 9 | 843D943G05 |
L64 | 2NC | Size 9 | 843D943G06 |
Accessories for Size 00–6 AC Contactors - Auxiliary Electrical Interlocks
Catalog Number (Obsolete) |
Style Number (Obsolete) |
Circuits | Part Number Current |
Style Number Current |
(L-56) | (2609D01G01) | 1NO and 1NC | J11 | 9084A17G01 |
(L-56D) | (2609D01G02) | 2NO | J20 | 9084A17G02 |
(L-56E) | (2609D01G03) | 1NO and 1NC | J11 | 9084A17G01 |
(L-56B) | (2609D01G04) | 2NO | J20 | 9084A17G02 |
(L-56H) | (2609D01G05) | 2NO | J20 | 9084A17G02 |
(L-56J) | (2609D01G06) | 1NO and1NC DB | J1C | 9084A17G04 |
(L-56A) | (2609D01G07) | N/A | N/A | N/A |
(L-56B) | (2609D01G08) | N/A | N/A | N/A |
(L-56F) | (2609D01G09) | N/A | N/A | N/A |
(L-56G) | (2609D01G10) | 1NO and 1NC DB | J1C | 9084A17G04 |
(L-56C) | (2609D01G11) | 2NC | J02 | 9084A17G03 |
(L-56M) | (2609D01G12) | N/A | N/A | N/A |
(L-56P) | (2609D01G17) | 1NO and 1NC | J11 | 9084A17G01 |
(L-56R) | (2609D01G18) | 2NC | J02 | 9084A17G03 |
(L-56S) | (2609D01G19) | 1NO and 1NC | J11 | 9084A17G01 |
Model J–K, Sizes 3 and 4 Kits (1)
Part | Poles | Size 3-Model J Style Number |
Size 4-Model J (2) Style Number |
Size 4-Model K (3) Style Number |
Contact Kit | 2 | 626B187G12 | 626B187G16 | 5250C81G16 |
3 | 626B187G13 | 626B187G17 | 5250C81G17 | |
4 | (4) | (6) | 5250C81G18 | |
5 | (5) | (7) | 5250C81G19 | |
Arc Box | 2, 3 | 6714C74G09 | 6714C74G11 | 6714C74G11 |
4, 5 | 6714C74G10 | 6714C74G12 | 6714C74G12 | |
Cross Bar | 2, 3 | 672B788G36 | 672B788G36 | 672B788G40 |
4, 5 | 672B788G38 | 672B788G38 | - | |
Upper Base | 2, 3 | 672B788G37 | 672B788G37 | 672B788G52 |
4, 5 | 672B788G39 | 672B788G39 | - | |
Lower Base | 2, 3 | 1250C33G03 | 1250C33G03 | 1250C33G10 |
4, 5 | 1250C33G06 | 1250C33G06 | - | |
KO spring (package of 10) | All | 503C796G02 | 503C796G02 | 672B788G50 |
Terminal line/load (package of 3) | All | 372B357G12 | 372B357G18 | 372B357G18 |
Notes:
(1) Model C contact tips and coils 00-4, two-, three-, four- and five-pole contactors are same as Model J. All other parts are unavailable.
(2) For 200A A202 magnetically latched lighting contactors order three-pole contact kit style 672B788G07.
(3 Model K replaces Model J, offering superior design life characteristics. Renewal parts are different. Use parts for proper model only.
(4) Use quantity two of 626B187G12.
(5) Use quantity one each of 626B187G12 and 626B187G13.
(6) Use quantity two of 626B187G16.
(7) Use quantity one each of 626B187G16 and 626B187G17.
Accessories for Model J–K, Series 3, 4
DC Coils 1
Voltage | Model J Size 3, 4 Two-, Three-Pole Style Number |
24 | 1255C68G04 |
48 | 1255C68G05 |
125 | 1255C68G01 |
250 | 1255C68G02 |
125/250 (2) | 1255C68G03 |
AC Coils
Voltage | Hz | Model J Size 3, 4 Two-, Three-Pole Style NUmber |
Four-, Five-Pole Style Number |
Model K Size 4 (3) Two-, Three-Pole Style Number |
Four-, Five-Pole Style Number |
120/110 | 60/50 | 505C633G01 | 505C635G01 | 5250C79G01 | 5250C80G01 |
208 | 60 | 505C633G02 | 505C635G02 | 5250C79G02 | 5250C80G02 |
600/550 | 60/50 | 505C633G05 | 505C635G05 | 5250C79G05 | 5250C80G05 |
380 | 50 | 505C633G07 | 505C635G07 | 5250C79G07 | 5250C80G07 |
240/220 | 60/50 | 505C633G12 | 505C635G12 | 5250C79G12 | 5250C80G12 |
480/440 | 60/50 | 505C633G13 | 505C635G13 | 5250C79G13 | 5250C80G13 |
24 | 60 | 505C633G34 | N/A | 5250C79G34 | N/A |
277 | 60 | 505C633G14 | N/A | 5250C79G14 | N/A |
240/480 (2) | 60/60 | 505C633G03 | 505C635G03 | 5250C79G03 | 5250C80G03 |
120/244 (2) | 60/60 | 505C633G10 | 505C635G10 | 5250C79G10 | 5250C80G10 |
A201 Contactors—Size 5–9 / GCA 530/630—GPD 7, 8, 9 Kits (4)
Part | Size 5 Style Number |
Size 6 Style Number |
Size 7 Style Number |
Size 8 Style Number |
Size 9 Style Number |
Contact kit (one per pole) | 477B477G05 (5) | 2066A10G11 | 461A757G17 | 646C829G05 | 5264C42G01 (6) |
5264C42G02 (7) | |||||
Arc box | 2050A15G45 | 2066A10G45 | 831D580G01 | 831D580G01 | 9917D69G02 |
Magnet assembly | 2050A15G46 | 2050A15G46 | N/A | N/A | N/A |
Mag. spg. kit | 2050A15G47 | 2050A15G47 | N/A | N/A | N/A |
Acr cup kit | 2050A15G48 | N/A | N/A | N/A | N/A |
Load conversion kit | 2050A15G49 | 2066A10G49 | N/A | N/A | N/A |
Line conversion kit | 2050A15G50 | 2066A10G50 | N/A | N/A | N/A |
K.O. spring–6 | 2050A15G51 | 2066A10G46 | N/A | N/A | N/A |
C.T. 300/5 | 655C285H03 | N/A | N/A | N/A | N/A |
C.T. 400/5 | 655C285H04 | N/A | N/A | N/A | N/A |
C.T. 600/5 (8) | N/A | 2066A10G18 | N/A | N/A | N/A |
C.T. 800/5 (8) | N/A | 2066A10G19 | N/A | N/A | N/A |
Phase barrier | N/A | N/A | 640C441G01 | 640C441G01 | 5264C35G03 (6) |
Cross bar | 2050A15G12 | 2066A10G15 | N/A | N/A | N/A |
Shunt | N/A | 2066A10G48 | 650C129G01 | 646C831G02 (9) | 5264C39G02 (10) |
Notes:
(1) Use only on units originally supplied with DC coil. |
(7) F.C. |
Accessories for A201 Contactors - Coils (Sizes 5 and 6)
Voltage | Hz | Size 5 Style Number |
Size 6 Style Number |
110/120 | 60 | 2050A14G05 | 2050A12G05 |
110/120 | 50 | 2050A14G06 | 2050A12G06 |
200/208 | 50 | 2050A14G07 | 2050A12G07 |
220/240 | 50 | 2050A14G08 | 2050A12G08 |
200/208 | 60 | 2050A14G09 | 2050A12G09 |
220/240 | 60 | 2050A14G10 | 2050A12G10 |
277/303 | 60 | 2050A14G12 | 2050A14G12 |
380/415 | 50 | 2050A14G14 | 2050A12G14 |
440/480 | 60 | 2050A14G15 | 2050A12G15 |
440/480 | 50 | 2050A14G16 | 2050A12G16 |
550/600 | 60 | 2050A14G17 | 2050A12G17 |
550/600 | 50 | 2050A14G18 | 2050A12G18 |
380/415 | 60 | 2050A14G19 | 2050A12G19 |
120/240 | 60 | 2050A14G20 | 2050A12G20 |
24 DC | - | 2050A14G21 | 2050A12G21 |
48 DC | - | 2050A14G22 | 2050A12G22 |
125 DC | - | 2050A14G25 | 2050A12G25 |
250 DC | - | 2050A14G27 | 2050A12G27 |
Accessories for A201 Contactors - Coils (Sizes 7 - 9)
Line Voltage | Style Number | Required |
Sizes 7 and 8 | ||
125 Vdc | 438C805G04 | 2 |
230 Vdc | 438C805G02 | 2 |
250 Vdc | 438C805G03 | 2 |
110/120 Vac (1)(4) | 438C805G12 | 2 |
220/240 Vac (2)(4) | 438C805G11 | 2 |
380 Vac (3)(4) | 438C805G15 | 2 |
440/480 Vac (3)(4) | 438C805G10 | 2 |
440/480 Vac (3)(4) | 438C805G13 | 2 |
Size 9 | ||
110 Vdc | 5264C34G01 (5) | - |
Notes:
(1) Rectifier 125V 2018A40G01 (one required).
(2) Rectifier 250V 2018A40G02 (one required).
(3) Rectifier 600V 2018A40G03 (one required).
(4) These coils require an external rectifier. If the rectifier needs replacement, order by the
appropriate style number.
(5) Contains coil and resistor.