Menu

Eaton E26BPV3
48 Vdc/Vac Intermittent Alarm Unit

E26 Alarm Unit

E26
Intermittent Alarm Unit


Type = Intermittent

Voltage = 48 Vac/Vdc

Series Part Numbers

Description Voltage Part Number
4.5 mA 12 Vac/Vdc E26BPV1
12.6 mA 24 Vac/Vdc E26BPV2
9.4 mA 48 Vac/Vdc E26BPV3
11.5 mA 120 Vac/Vdc E26BPV4
5.1 mA 240 Vac/Vdc E26BPV5

NOTES:
(1) Volume adjustment range: 64 dB to 90 dB typical current draw (mA).

E26 Technical Data and Specifications

Description Specification
Mechanical Ratings
Shock (IEC 68-2-27) 11 ms, 15g
Vibration (IEC 68-2-6) 10 sweeps 10–150 Hz, 2g
Bump (IEC 68-2-29) 1000 pulses, 6 ms, 15g
Climate Conditions
Operating Maximum 104°F (40°C) at 95% RH,
Temperature –4° to 140°F (–20° to 60°C)
Storage Temperature –40° to 176°F (–40° to 80°C)
Materials
Cover Polycarbonate
Lenses Polycarbonate
Stacklight base Nylon
Extension tubes Aluminum
Mounting base Zinc die cast
Terminals
Single conductor 14–30 AWG (2.5–0.05 mm2)
Two conductors (same size) 18–26 AWG (0.75–0.14 mm2)
Do not mix solid and stranded wire in the same termina
Recommended tightening torque 4.4–5.3 lb-in (0.5–0.6 Nm)
Electrical Ratings
Insulation voltage (Ui) 690V
Operational voltage (Ue) 250V
Impulse withstand voltage (Uimp) 1.5 kV
Bulb Specifications
Incandescent lamp type BA15d
Maximum lamp wattage 6W
Bulbs—average life
Incandescent
7,000 to 12,000 hrs. (based on voltage)
Xenon flasher 20,000 hrs.
LED 60,000 to 100,000 hrs. (based on colors)
LED/Incandescent Comparison
Incandescent lamps Average operating life of 7,000 hours
Each lamp can be used with any color lens
Low cost results in short term savings
LED lamps Average operating life of 60,000 to 100,000 hours
Low power consumption
Extended life results in long-term savings

Dimensions