Eaton |
MSC-DE-1.2-M17-SP(220V50HZ,240V60HZ) shown |
XTFCE004BCCSB Motor Starter |
|||||
Short Circuit Current Rating | Setting
Range Overload Release Ir |
Old Moeller Part Number |
New Eaton Part Number |
||
---|---|---|---|---|---|
240 V kA |
480 Y 277 V kA |
600 Y 347 V kA |
0.3...1.2A | MSC-DE-4-M17-SP (220V50HZ,240V60HZ) |
XTFCE004BCCSB |
XTFCE004BCCSB Technical Data |
Delivery programme | |
---|---|
Basic function | Type E DOL starters (complete devices) |
Basic device | MSC |
Connection to SmartWire-DT |
No |
Components for | North America |
Maximum Motor Rating | |||
---|---|---|---|
AC HP = PS | |||
200 V 208 V | HP | 0.75 | |
230 V 240 V | HP | 0.75 | |
460 V 480 V | HP | 2 | |
Short Circuit Current Rating | |||
240 V | kA | 18 | |
480 Y / 277 V | kA | 18 | |
Setting range | |||
Setting range of overload releases | Ir | A | 1 - 4 |
Short-circuit releases | |||
Non-delayed | Irm | A | 168 |
Contact sequence | |||
Actuating voltage | 220 v 50 Hz 240 V 60 Hz |
Motor-protective circuit-breakers PKE12/XTU-4 |
Contactor DILM17-10(...) |
DOL starter wiring set Mechanical connection element and electrical electric contact module BK25/3-PKZ0-E |
Notes The DOL starter type E (complete devices) consists of a PKE motor-protective circuit-breaker with AK-PKZ0, a DILM contactor and an extension terminal BK25/3-PKZ0-E. Motor-protective circuit-breaker and contactor mounted on top hat rail adapter plate. The connection of the main circuit between PKE and contactor is established with electrical contact modules. |
Technical data | |||
---|---|---|---|
General | |||
Standards | IEC/EN 60947-4-1, VDE 0660 | ||
Main conducting paths | |||
Rated impulse withstand voltage | Uimp | V AC | 6000 |
Overvoltage category/pollution degree | III/3 | ||
Rated operational voltage | Ue | V | 208 - 600 |
Rated operational current | |||
Open, 3-pole: 50-60 Hz 380 V 400 V |
Ie | A | 4 |
Additional technical data | |||
Motor protective circuit breaker PKZM0, PKE |
PKE motor-protective circuit-breaker, see motor-protective circuit-breaker product group DILM contactors, see contactors product group |
||
DILM contactors Power consumption of the coil in a cold state and 1.0 x Uc Dual-voltage coil 50 Hz |
Sealing | W | 2.1 |
Data for design verification according to IEC/EN 61439 | |||
Technical data for design verification | |||
Heat dissipation capacity | Pdiss | W | 0 |
IEC/EN 61439 design verification | — | ||
10.2 Strength of materials and parts |
— | ||
10.2.2 Corrosion resistance |
Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
||
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES |
Does not apply, since the entire switchgear needs to be evaluated. |
||
10.4 Clearances and creepage distances |
Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
||
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
||
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility. | ||
10.8 Connections for external conductors |
Is the panel builder's responsibility. | ||
10.9 Insulation properties | — | ||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility. | ||
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
||
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
||
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
||
Technical data ETIM 5.0 | |||
Low-voltage industrial components (EG000017) / Motor starter combination (EC001037) | |||
Electric engineering, automation, process control engineering / Low-voltage switch technology / Load breakout, motor breakout / Motor starter combination (ecl@ss8-27-37-09-05 [AJZ718009]) |
|||
Function | — | Direct starter | |
Rated control supply voltage Us at AC 50HZ |
V | 220 - 220 | |
Rated control supply voltage Us at AC 60HZ |
V | 240 - 240 | |
Rated control supply voltage Us at DC |
V | 0 - 0 | |
Voltage type for actuating | — | AC | |
Rated operation power at AC-3, 400 V |
kW | 7.5 | |
Rated operation current Ie |
A | 16.1 | |
Conditioned rated short-circuit current Iq |
kA | 100 | |
Setting range overload protector | A | 1 - 4 | |
With short-circuit release | — | Yes | |
Type of coordination | — | 2 | |
Connection type main current circuit |
— | Screw connection | |
Degree of protection (IP) |
— | IP20 | |
Suited for bus connection |
— | Yes |
XTFCE004BCCSB Dimensions |
||
© 2016 KMParts.com, Inc. All rights reserved.