Other product lines for the Xstart Contactors include: |
||||
DILM7 - DILM32 Xstart Contactors |
Overload Relays |
Auxiliary Contacts |
Timer Modules |
Contact Suppressors and Voltage Indicators |
Connectors |
|||
| Type | Description | For use with | |
| V0DILE |
|
Provides a mechanical link when coupling two contactors
together.
Distance between Contactors = 0 mm |
DILEM |
| DILM32-XVB |
|
DILM7 - DILM12
DILM17 - DILM32 DILM40 - DILM65 DILM80 - DILM150 |
|
| DILM150-XVB |
|
DILM80 - DILM150 | |
Mechanical Interlocks |
|||
| MVDILE |
|
For two contactors with AC or DC operated magnet systems.
Distance between Contactors = 0 mm. Mechanical Lifespan = 2.5 x 106 operations. Additional auxiliary contact modules can be fitted. |
DILEM |
| DILM12-XMV |
|
For two contactors with AC or DC operated magnet systems.
Distance between Contactors = 0 mm. Mechanical Lifespan = 2.5 x 106 operations. Additional auxiliary contact modules can be fitted. |
DILM7 - DILM12
DILMP20 |
| DILM32-XMV |
|
DILM17 - DILM32 | |
| DILM65-XMV | DILM40 - DILM65 | ||
| DILM150-XMV | DILM80 - DILM150 | ||
| DILM500-XMV |
|
For two contactors with the same or different magnetic
systems.
Mechanical lifespan 5 x 106 operations. No auxiliary contact is possible between the mechnical interlock and contactor. Combination with same frame size only. Distance between contactors: 15 mm |
DILM185 – DILM500 |
| DILM820-XMV |
For two contactors with the same or different magnetic
systems.
Mechanical lifespan 5 x 106 operations. No auxiliary contact is possible between the mechnical interlock and contactor. DILM820-XMV consists of interlock element and mounting support plate. |
DILM580 – DILM1000 | |
Reversing Kits |
|||
| MVS-WB-EM |
|
Consisting of one 3-pole paralleling link with control
bridge and reversing link
with A2 bridge. |
DILEM
(+MVDILEM) |
| DILM12-XRL |
|
In addition to the electrical interlock, the following
control connections are
integrated: • K1M: A1 – K2M: 21 • K1M: 21 – K2M: A1 • K1M: A2 – K2M: A1 |
DILM7/9/12 mains
DILM7/9/12 delta DILM7/9/12 star |
| DILM32-XRL |
DILM17/25/32 mains
DILM17/25/32 delta DILM17/25/32 star |
||
Star-Delta Wiring Kits |
|||
| DILM12-XSL |
|
The following control cables are integrated in addition to
electrical interlock: • K3M: A1 – K5M: 21 • K3M: 21 – K5M: A1 • K3M: A2 – K5M: A1 |
DILM7/9/12 mains
DILM7/9/12 delta DILM7/9/12 star |
| DILM32-XSL |
DILM17/25/32 mains
DILM17/25/32 delta DILM17/25/32 star |
||
Bridges |
|||
|
Star-Point Bridges |
|||
| S1DILEM |
|
Finger-safe (in accordance with IEC 536). | DILEM |
| DILM12-XS1 | DILM7 - DILM12 | ||
| DILM32-XS1 | DILM17 - DILM32 | ||
| DILM65-XS1 | DILM40 - DILM65 | ||
| DILM400-XS1 |
|
A cover is included for protection against accidental contact. | DILM80 - DILM150 |
| DILM500-XS1 | DILM500 | ||
|
Paralleling Bridges (Consisting of two paralleling links) |
|||
| P1DILEM |
|
4th pole can be broken off.
AC-1 current carrying capacity of the open contactor increases by a factor of 2.5. Protected against accidental contact (in accordance with IEC 536). |
|
| DILM12-XP1 |
|
4th pole can be broken off.
AC-1 current carrying capacity of the open contactor increases by a factor of 2.5. Protected against accidental contact (in accordance with IEC 536). Terminal capacity can be found in the Technical Data section. |
|
| DILM32-XP1 |
|
DILM7 - DILM12 | |
| DILM32-XP1 | DILM40 - DILM65 | ||
| DILM185-XP1 |
|
3-pole
AC-1 current carrying capacity of the open Contactor increases by a factor of 2.5. A cover is included for protection against accidental contact. |
DILM185 |
Connection Tabs |
|||
| BT483 |
|
1 x 6.3 x 0.8 or 2 x 2.8 x 0.8 mm
For auxiliary contact and coil connections. Use connectors with insulated sleeves. Standard quantity: 100 Must be ordered in standard quantity. |
DILEM
DILM185 – DILM1000 |
| BT2571 |
|
DILM185 –
DILM1000 |
|
Terminal Blocks and Kits |
|||
|
Cable Terminal Blocks |
|||
| DILM225-XKU-S |
|
For cable connection. Single or double cables may be
connected.
See Technical Data for terminal capacity. |
DILM185
DILM225 |
| DILM400-XKU-S | DILM250 – DILM400 | ||
| DILM500-XK-CNA |
Consists of three individual terminals (Cu, Al), with
integrated control circuit
terminal. Terminal cover included. Terminal capacity: 2 X (AWG4 to MCM500) |
DILM500/22 | |
| DILM650-XK-CNA |
Consists of three individual terminals (Cu, Al), with
integrated control circuit
terminal. Terminal cover included. Terminal capacity: 2 X (AWG2 to MCM500) |
DILM580/22
DILM650/22 |
|
| DILM820-XK-CNA |
Consists of three individual terminals (Cu, Al).
Terminal capacity: 4 X (AWG2 to MCM500) |
DILM750/22
DILM820/22 |
|
|
Flat Strip Conductor Terminal Kit (with Control Circuit Terminal consisting of 3 Flat Strip Conductor Terminals) |
|||
| DILM650-XKB-S |
|
For bus and flexibus connection. | DILM500 – DILM650 |
| DILM820-XKB-S |
DILM750
DILM820 |
||
Covers |
|||
|
Sealable Shrouds |
|||
| HDILE |
|
Cover snap-mounts onto the device and can be sealed to prevent tampering. | DILEM |
|
Terminal Cover |
|||
| DILM400-XHB |
|
Protection against shock hazards and accidental contact. | DILM185 – DILM400 |
| DILM500-XHB | DILM500 | ||
| DILM650-XHB | DILM580 – DILM650 | ||
| DILM820-XHB | DILM750 – DILM1000 | ||