Eaton/Moeller |
NHI11-PKZ0 shown |
NHI21-PKZ0 Side Mounted Auxiliary Contact |
||||
Description | Contacts | For Use With | Old Moeller Part Number |
New Eaton Part Number |
---|---|---|---|---|
Standard Side Mounted Auxiliary Contact |
2 N.O. 1 N.C. |
PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE |
NHI21-PKZ0 | XTPAXSA21 |
|
NHI21-PKZ0 Technical Data |
|
General | |
---|---|
Moeller Part No. | NHI21-PKZ0 |
Eaton Part No. | XTPAXSA21 |
Delivery program | |
Product range | Standard auxiliary contact |
For use with | PKZ0(4) standard auxiliary contacts |
Contacts | |
N/O = Normally open | 2 N.O. |
N/C = Normally closed | 1 N.C. |
Connection technique | Screw terminals |
For use with | PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE |
Notes: Can be fitted to the right of motor-protective circuit-breakers, transformer-protective circuit-breakers, motor-protective circuit-breakers for starter combinations. Can be combined with: AGM, NHI-E-... trip-indicating auxiliary contact |
|
Technical data | |
Auxiliary contacts | |
Rated impulse withstand voltage (Uimp) | 6000 |
Overvoltage category/pollution degree | III/3 |
Rated operational voltage (Ue) | 500 V AC |
250 V DC | |
Safe isolation to EN 61140 Between auxiliary contacts and main contacts |
690 V AC |
Rated operational current AC-15 | |
220 - 240 V | 3.5 A |
380 - 415 V | 2 A |
440 V 500 V | 1 A |
Rated operational current DC-13 L/R - 100 ms | |
24 V | 2 A |
60 V | 1.5 A |
110 V | 1 A |
220 V | 0.25 A |
Lifespan, mechanical (Operations) | > 0.1 |
Lifespan, electrical (Operations) | 0.05 |
Control circuit reliability (Failure rate) | <10-8, one failure at 100 million operations (at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) |
interlocked opposing contacts | yes |
Short-circuit rating without welding | |
Fuseless (Type) | FAZ-B4/1-HI |
Fuse (A gG/gL) | 10 |
Terminal capacities | |
Solid or flexible conductor, with ferrule | 0,75 - 2,5 |
Solid or stranded | 18 - 14 |
Design verification as per IEC/EN 61439 | |
Technical data for design verification | |
Rated operational current for specified heat dissipation |
3.5 A |
Heat dissipation per pole, current-dependent |
0.04 W |
Heat dissipation capacity | 0 W |
IEC/EN 61439 design verification | |
10.2 Strength of materials and parts | |
10.2.2 Corrosion resistance | Meets the product standard's requirements. |
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements. |
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements. |
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard's requirements. |
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.7 Inscriptions | Meets the product standard's requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard's requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility. |
10.8 Connections for external conductors | Is the panel builder's responsibility. |
10.9 Insulation properties | |
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Technical data ETIM 5.0 | |
Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041) | |
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block (ecl@ss8-27-37-13-02 [AKN342009]) |
|
Number of contacts as change-over contact | 0 |
Number of contacts as normally open contact | 1 |
Number of contacts as normally closed contact | 1 |
Rated operation current Ie at AC-15, 230 V | 3.5 A |
Type of electric connection | Screw connection |
Mounting method | Side mounting |
Approvals | |
Product Standards | UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking |
UL File No. | E36332 |
UL Category Control No. | NLRV |
CSA File No. | 165628 |
CSA Class No. | 3211-05 |
North America Certification | UL listed, CSA certified |
Specially designed for North America | No |
NHI21-PKZ0 Dimensions |
© 2016 KMParts.com, Inc. All rights reserved.