NHI-E-11-PKZ0
Front Mount Auxiliary Contact



Moeller NHI-E-11-PKZ0 - Side Mounted Contact

NHI-E-11-PKZ0 shown


NHI-E-11-PKZ0 Front-Mount Auxiliary Contact

Description Contacts For Use With Old Moeller
Part Number
New Eaton
Part Number
Standard Side Mounted
Auxiliary Contact
1 N.O.
1 N.C.
PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE
NHI-E-11-PKZ0 XTPAXFA11
  • Can be mounted on the top of the motor protectors beginning with Serial No. 01 or higher. 45mm width of the motor protector remains unchanged.


NHI-E-11-PKZ0 Technical Data

General
Moeller Part No. NHI-E-11-PKZ0
Eaton Part No. XTPAXFA11
Delivery program
Product range Standard auxiliary contact
For use with PKZ0(4) standard auxiliary contacts
Contacts
N/O = Normally open 1 N.O.
N/C = Normally closed 1 N.C.
Connection technique Screw terminals
For use with PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE
Notes:
Can be retrofitted to motor-protective circuit-breakers, transformer-protective circuit-breakers, motor-protective circuit-breakers for starter combinations from serial number 01. 45 mm (PKZM0 and PKZM01) or 55 mm (PKZM4) widths of the motor-protective circuit-breakers remain unchanged.
NHI-E...-PKZ0-C not usable for MSC...-type motor starter combinations.
Technical data
Auxiliary contacts
Rated impulse withstand voltage (Uimp) 4000
Overvoltage category/pollution degree III/3
Rated operational voltage (Ue) 440 V AC
250 V DC
Safe isolation to EN 61140
Between auxiliary contacts and main contacts
690 V AC
Rated operational current AC-15
220 - 240 V 1 A
Rated operational current DC-13 L/R - 100 ms
24 V 2 A
Lifespan, mechanical (Operations) > 0.1
Lifespan, electrical (Operations) 0.1
Control circuit reliability (Failure rate) <10-8, one failure at 100 million operations
(at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA)
interlocked opposing contacts yes
Short-circuit rating without welding  
Fuse (A gG/gL) 10
Terminal capacities
Solid or flexible conductor, with ferrule 0,75 - 2,5
Solid or stranded 18 - 16
Design verification as per IEC/EN 61439
Technical data for design verification
Rated operational current
for specified heat dissipation
1 A
Heat dissipation per pole,
current-dependent
0.01 W
Heat dissipation capacity 0 W
IEC/EN 61439 design verification
10.2 Strength of materials and parts  
10.2.2 Corrosion resistance Meets the product standard's requirements.
10.2.3.1 Verification
of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance
of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Verification of resistance
of insulating materials to abnormal
heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements.
10.2.5 Lifting Does not apply,
since the entire switchgear
needs to be evaluated.
10.2.6 Mechanical impact Does not apply,
since the entire switchgear
needs to be evaluated.
10.2.7 Inscriptions Meets the product
standard's requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply,
since the entire switchgear
needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard's requirements.
10.5 Protection against electric shock Does not apply,
since the entire switchgear
needs to be evaluated.
10.6 Incorporation
of switching devices and components
Does not apply,
since the entire switchgear
needs to be evaluated.
10.7 Internal electrical circuits
and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors Is the panel builder's responsibility.
10.9 Insulation properties  
10.9.2 Power-frequency electric strength Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage Is the panel builder's responsibility.
10.9.4 Testing of enclosures
made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise The panel builder is responsible
for the temperature rise calculation.
 Eaton will provide heat dissipation
data for the devices.
10.11 Short-circuit rating Is the panel builder's responsibility.
The specifications for the switchgear
must be observed.
10.12 Electromagnetic compatibility Is the panel builder's responsibility.
The specifications for the
switchgear must be observed.
10.13 Mechanical function The device meets the requirements,
provided the information in the
instruction leaflet (IL) is observed.
Technical data ETIM 5.0
Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041)
Electric engineering, automation, process control engineering / Low-voltage switch technology /
Component for low-voltage switching technology / Auxiliary switch block
(ecl@ss8-27-37-13-02 [AKN342009])
Number of contacts as change-over contact 0
Number of contacts as normally open contact 1
Number of contacts as normally closed contact 1
Rated operation current Ie at AC-15, 230 V 1 A
Type of electric connection Screw connection
Mounting method Front Fastening
Approvals
Product Standards UL 508; CSA-C22.2 No. 14;
IEC60947-4-1; CE marking
UL File No. E36332
UL Category Control No. NLRV
CSA File No. 165628
CSA Class No. 3211-05
North America Certification UL listed, CSA certified
Specially designed for North America No


NHI-E-11-PKZ0 Dimensions


Inch to MM Conversion

Convert to MM

MM to Inch Conversion

Convert to Inches