Eaton/Moeller
AGM2-01-PKZ0
Side-Mount Trip Indicator Switch



Moeller AGM2-01-PKZ0 - Side Mounted Contact
AGM2-10-PKZ0 Schematic

AGM2-10-PKZ0 shown


AGM2-01-PKZ0 Side Mounted
Trip-Indicating Auxiliary Contacts

Description Contacts For Use With Old Moeller
Part Number
New Eaton
Part Number
Trip-Indicating
Auxiliary Contacts
2 X 1 N.C. PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE
AGM2-01-PKZ0 XTPAXSATR02
AGM2-01-PKZ0 Side Mounted Trip-Indicating Auxiliary Contacts

Can be retrofitted on the right side of motor-protective circuit-breakers Differential status indication
a) General trip indication (overload)
b) Short-circuit release
Short-circuits indicated locally by means of a red indicator that can be manually reset



AGM2-01-PKZ0 Technical Data

General
Moeller Part No. AGM2-01-PKZ0
Eaton Part No. XTPAXSATR20
Delivery program
Product range Trip-Indicating
Auxiliary Contacts
For use with PKZ0(4) standard auxiliary contacts
Contacts
N/O = Normally open 2 X 1 N.C.
Connection technique Screw terminals
For use with PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE
Can be combined
with auxiliary contact
NHI11-PKZ0
NHI12-PKZ0
NHI21-PKZ0
NHI-E-...
Notes:
Can be fitted to the right of motor-protective circuit-breakers, transformer-protective circuit-breakers, motor-protective circuit-breakers for starter combinations. Can be combined with: AGM, NHI-E-... trip-indicating auxiliary contact
Technical data
Auxiliary contacts
Rated impulse withstand voltage (Uimp) 6000
Overvoltage category/pollution degree III/3
Rated operational voltage (Ue) 500 V AC
250 V DC
Safe isolation to EN 61140
Between auxiliary contacts and main contacts
690 V AC
Rated operational current AC-15
220 - 240 V 3.5 A
380 - 415 V 2 A
440 V 500 V 1 A
Rated operational current DC-13 L/R - 100 ms
24 V 2 A
60 V 1.5 A
110 V 1 A
220 V 0.25 A
Lifespan, mechanical (Operations) > 0.1
Lifespan, electrical (Operations) 0.05
Control circuit reliability (Failure rate) <10-8, one failure at 100 million operations
(at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA)
interlocked opposing contacts yes
Short-circuit rating without welding  
Fuseless (Type) FAZ-B4/1-HI
Fuse (A gG/gL) 10
Terminal capacities
Solid or flexible conductor, with ferrule 0,75 - 2,5
Solid or stranded 18 - 14
Design verification as per IEC/EN 61439
Technical data for design verification
Rated operational current
for specified heat dissipation
3.5 A
Heat dissipation per pole,
current-dependent
0.04 W
Heat dissipation capacity 0 W
IEC/EN 61439 design verification
10.2 Strength of materials and parts  
10.2.2 Corrosion resistance Meets the product standard's requirements.
10.2.3.1 Verification
of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance
of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Verification of resistance
of insulating materials to abnormal
heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements.
10.2.5 Lifting Does not apply,
since the entire switchgear
needs to be evaluated.
10.2.6 Mechanical impact Does not apply,
since the entire switchgear
needs to be evaluated.
10.2.7 Inscriptions Meets the product
standard's requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply,
since the entire switchgear
needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard's requirements.
10.5 Protection against electric shock Does not apply,
since the entire switchgear
needs to be evaluated.
10.6 Incorporation
of switching devices and components
Does not apply,
since the entire switchgear
needs to be evaluated.
10.7 Internal electrical circuits
and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors Is the panel builder's responsibility.
10.9 Insulation properties  
10.9.2 Power-frequency electric strength Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage Is the panel builder's responsibility.
10.9.4 Testing of enclosures
made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise The panel builder is responsible
for the temperature rise calculation.
 Eaton will provide heat dissipation
data for the devices.
10.11 Short-circuit rating Is the panel builder's responsibility.
The specifications for the switchgear
must be observed.
10.12 Electromagnetic compatibility Is the panel builder's responsibility.
The specifications for the
switchgear must be observed.
10.13 Mechanical function The device meets the requirements,
provided the information in the
instruction leaflet (IL) is observed.
Technical data ETIM 5.0
Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041)
Electric engineering, automation, process control engineering / Low-voltage switch technology /
Component for low-voltage switching technology / Auxiliary switch block
(ecl@ss8-27-37-13-02 [AKN342009])
Number of contacts as change-over contact 0
Number of contacts as normally open contact 2
Number of contacts as normally closed contact 0
Rated operation current Ie at AC-15, 230 V 3.5 A
Type of electric connection Screw connection
Mounting method Side mounting
Approvals
Product Standards UL 508; CSA-C22.2 No. 14;
IEC60947-4-1; CE marking
UL File No. E36332
UL Category Control No. NLRV
CSA File No. 165628
CSA Class No. 3211-05
North America Certification UL listed, CSA certified
Specially designed for North America No


AGM2-01-PKZ0 Dimensions

AGM2-01-PKZ0 Dimensions

Inch to MM Conversion

Convert to MM

MM to Inch Conversion

Convert to Inches