Eaton
|
|
Series-C Frame Size - K Part Index CLICK HERE |
|
Type KD (3-Pole) Shown |
Number of Poles |
Amperes | Interrupting Capacity |
Type of Trip |
Terminals |
---|---|---|---|---|
4 | 125 | Standard 600 Vac Rated 35 kAIC at 480 Vac |
Interchangeable Adjustable Thermal-Magnetic |
Standard |
NEMA/UL 489/CSA Interrupting Capacity Ratings | |||||||||
Circuit Breaker Type |
Number of Poles |
Interrupting Capacity (kA Symmetrical Amperes) | |||||||
---|---|---|---|---|---|---|---|---|---|
Volts AC (50/60 Hz) | Volts DC | ||||||||
240 | 277 | 480 | 600 | 250(1)(2) | |||||
DK | 2, 3 | 65 | — | — | — | 10 | |||
KDB | 2, 3, 4 | 65 | — | 35 | 25 | 10 | |||
KD | 2, 3, 4 | 65 | — | 35 | 25 | 10 | |||
HKD, HKDB | 2, 3, 4 | 100 | — | 65 | 35 | 22 | |||
KDC(4) | 2, 3, 4 | 200 | — | 100 | 65 | 22 | |||
CKD | 3 | 65 | — | 35 | 25 | — | |||
CHKD | 3 | 100 | — | 65 | 35 | — | |||
IEC 157-1 (P1) Interrupting Capacity Ratings | |||||||||
Circuit Breaker Type |
Number of Poles |
Interrupting Capacity (kA Symmetrical Amperes) | |||||||
Volts AC (50/60 Hz) | Volts DC | ||||||||
240 | 380 | 415 | 440 | 500 | 600 | 250(2)(3) | |||
DK | 2, 3 | 65 | — | — | — | — | — | 10 | |
KDB | 2, 3, 4 | 65 | 40 | 40 | — | — | — | 10 | |
KD | 2, 3, 4 | 65 | 40 | 40 | — | — | — | 10 | |
HKD, HKDB | 2, 3, 4 | 100 | 65 | 65 | — | — | — | 22 | |
KDC | 2, 3, 4 | 200 | 100 | 100 | — | — | — | 22 |
NOTES:
(1) Two-pole breaker supplied in three-pole frame. Current carrying parts omitted from center pole.
(2) Two-pole circuit breaker or two outside poles of three-pole circuit breaker.
(3) Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.
(4) Current limiting.
Trip Unit Type | Digitrip RMS 310+ |
---|---|
Breaker Type | |
Frame | K |
Ampere range | 250–400A |
Continuous current range (A) | 55–400A |
Ground fault pickup (A) | 50–400A |
Interrupting capacities at 480 Vac (kAIC) | 35, 65, 100 |
100% rated | Yes |
Protection | |
Ordering options | LS, LSI, LSG, LS(A), LSIG, LSI(A), ALSI, ALSIG, ALSI(A) |
Arcflash Reduction Maintenance System | ALSI, ALSIG, ALSI(A) |
Interchangeable trip unit | Yes |
High load alarm, trip (suffix B20) | Yes |
Ground fault alarm, trip (suffix B21) | LSG, LSIG, ALSIG |
Zone selective interlock (suffix ZG) | Yes |
Cause of trip indication (Catalog Nos: DIGIVIEW, DIGIVIEWR06, TRIP-LED) |
Yes |
Thru-cover accessories | No |
310+ Settings | K-Frame | |||
---|---|---|---|---|
125A | 250A | 400A | ||
Ir = continuous current or long delay pickup (amperes) (All 310+) |
Ir\In | |||
A (=Ir) | 55 | 100 | 160 | |
B (=Ir) | 60 | 125 | 200 | |
C (=Ir) | 70 | 150 | 225 | |
D (=Ir) | 80 | 160 | 250 | |
E (=Ir) | 90 | 175 | 300 | |
F (=Ir) | 100 | 200 | 315 | |
G (=Ir) | 110 | 225 | 350 | |
H (=Ir=In) | 125 | 250 | 400 | |
tLD = long delay time (seconds) (All 310+) |
2 | 2 | 2 | 2 |
4 | 4 | 4 | 4 | |
7 | 7 | 7 | 7 | |
10 | 10 | 10 | 10 | |
12 | 12 | 12 | 12 | |
15 | 15 | 15 | 15 | |
20 | 20 | 20 | 20 | |
24 | 24 | 24 | 24 | |
ISD x Ir = short delay pickup (amperes) (All 310+) |
Position 1 | 2 | 2x | 2x |
Position 2 | 3 | 3x | 3x | |
Position 3 | 4 | 4x | 4x | |
Position 4 | 5 | 5x | 5x | |
Position 5 | 6 | 6x | 6x | |
Position 6 | 7 | 7x | 7x | |
Position 7 | 8 | 8x | 8x | |
Position 8 | 10 | 10x | 10x | |
Position 9 | 12 | 12x | 12x | |
Ig x In = ground fault pickup (amperes) (310+ w/ground fault) |
Position 1 | 25 | 50 | 80 |
Position 2 | 37.5 | 75 | 120 | |
Position 3 | 50 | 100 | 160 | |
Position 4 | 75 | 150 | 240 | |
Position 5 | 100 | 200 | 320 | |
Position 6 | 125 | 250 | 400 | |
Ii x In = instantaneous maintenance mode (amperes) (310+ w/maintenance mode) |
Position 1 (2.5x) |
312 | 625 | 1000 |
Position 2 (4x) | 312 | 625 | 1000 | |
Position 3 (6x) | 312 | 625 | 1000 | |
Position 4 | 312 | 625 | 1000 | |
Position 5 | 312 | 625 | 1000 | |
Position 6 | 312 | 625 | 1000 | |
Position 7 | 312 | 625 | 1000 |
Note: RMM on KD310+ is not adjustable; it is set at 2.5x.
Trip Unit Type | Digitrip OPTIM 550 | Digitrip OPTIM 1050 |
---|---|---|
rms sensing | Yes | Yes |
Breaker Type | ||
Frame | K | K |
Ampere range | 125–400A | 125–400A |
Interrupting rating at 480 volts | 35, 65, 100 (kA) | 35, 65, 100 (kA) |
Protection | ||
Ordering options | LSI, LSI(A), LSIG | LSI(A), LSIG |
Fixed rated plug (In) | Yes | Yes |
Overtemperature trip | Yes | Yes |
Long Delay Protection (L) | ||
Adjustable rating plug (In) | No | No |
Long delay pickup | 0.4–1.0 x (In) | 0.4–1.0 x (In) |
Long delay time I2t | 2–24 seconds | 2–24 seconds |
Long delay time I4t | 1–5 seconds | 1–5 seconds |
Long delay thermal memory | Yes | Yes |
High load alarm | 0.5–1.0 x Ir | 0.5–1.0 x Ir |
Short Delay Protection (S) | ||
Short delay pickup | 150–800% x (Ir) | 150–800% x (Ir) |
Short delay time I2t | 100–500 ms | 100–500 ms |
Short delay time flat | 100–500 ms | 100–500 ms |
Short delay time zone selective interlocking | Yes(1) | Yes |
Instantaneous Protection (I) | ||
Instantaneous pickup | 200–800% x (In) | 200–800% x (In) |
Discriminator | Yes | Yes |
Instantaneous override | Yes | Yes |
Ground Fault Protection (G) | ||
Ground fault alarm | 20–100% x (Is) | 20–100% x (Is) |
Ground fault pickup | 20–100% x (Is) | 20–100% x (Is) |
Ground fault delay I2t | 100–500 ms | 100–500 ms |
Ground fault delay flat | 100–500 ms | 100–500 ms |
Ground fault zone selective interlocking | Yes(1) | Yes |
Ground fault thermal memory | Yes | Yes |
System Diagnostics | ||
Status LEDs | Yes | Yes |
Cause of trip LEDs | Yes | Yes |
Magnitude of trip information | Yes | Yes |
Remote signal contact—ground alarm | Yes(1) | Yes |
Local auxiliary and bell alarm contact | Optional | Included |
System Monitoring | ||
Digital display | Yes(2) | Yes(2) |
Current | Yes | Yes |
Power and energy | No | Yes |
Power quality—harmonics | No | Yes |
Power factor | No | Yes |
Communications | ||
PowerNet | Yes(3) | Yes |
Testing | ||
Testing method | OPTIMizer, BIM, PowerNet | OPTIMizer, BIM, PowerNet |
Legend |
Notes: |
Number of Poles | Width | Height | Depth |
---|---|---|---|
2, 3 | 5.50 (149.7) | 10.13 (257.3) | 4.10 (104.1) |
4 | 7.22 (183.4) | 10.13 (257.3) | 4.10 (104.1) |