XTPR0 Accessories |
|||||||||
|
|||||||||
Cable Glands, Metric |
|||||||||
| Hole Diameter | External Diameter of Cable | ||||||||
|
V-M20 | 20.5 | 6 - 12 MM | ||||||
| V-M25 | 25.5 | 9 - 17 MM | |||||||
| V-M32 | 32.5 | 12 - 21 MM | |||||||
| V-M32G | 32.5 | 18 - 25 MM | |||||||
Metric Diaphragm Grommets |
|||||||||
| Hole Diameter | External Diameter of Cable | ||||||||
|
KT-M20 | 20.5 | 1 - 13 mm | ||||||
| KT-M25 | 25.5 | 1 - 18 mm | |||||||
| KT-M32 | 32.5 | 1 - 24 mm | |||||||
Door coupling handle IP65 |
|||||||||
|
|||||||||
| Color | Description | ||||||||
| XTPAXRHMB | Black | For use as main switch to IEC/EN 60204 | |||||||
| XTPAXRHMRY | Red/Yellow | For use as a main switch with Emergency-Stop function, to EN 60204 | |||||||
| XTPAXRHM90B | Black | For use as a main switch to EN 60204 in MCC power distribution systems and with PKZM0 installed when rotated by 90° | |||||||
| XTPAXRHM90RY | Red/Yellow | For use as a main switch with Emergency-Stop function to EN 60204 in MCC power distribution systems and with PKZM0 installed rotated by 90° | |||||||
Lockable rotary handle |
|||||||||
|
XTPAXLRH |
|
||||||||
Sealing facility |
|||||||||
| XTPAXSW |
|
||||||||
Indicator lights with neon bulb |
|||||||||
|
|
|||||||||
| Color | Voltage | For Use with: | |||||||
| XTPAXILWB(230V) |
|
110 – 230 |
|
||||||
| XTPAXILWN(400V) | 230 – 400 | ||||||||
| XTPAXILWC(500V) | 415 – 500 | ||||||||
| XTPAXILGB(230V) |
|
110 – 230 | |||||||
| XTPAXILGN(400V) | 230 – 400 | ||||||||
| XTPAXILGC(500V) | 415 – 500 | ||||||||
| XTPAXILRB(230V) |
|
110 – 230 | |||||||
| XTPAXILRN(400V) | 230 – 400 | ||||||||
Bus Bars
|
|||||||||
|
For motor-protective circuit-breakers/starters without side-fitted auxiliary contacts or voltage releases |
|||||||||
|
|
|||||||||
| Circuit Breakers | Length (mm) | Unit Width | |||||||
| XTPAXCLKA2D | 2 | 110 | 55 | ||||||
| XTPAXCLKA3D | 3 | 165 | 55 | ||||||
| XTPAXCLKA4D | 4 | 220 | 55 | ||||||
|
For XTPR0 each with an auxiliary contact or trip-indicating auxiliary contact fitted on the right |
|||||||||
|
|
|||||||||
| Circuit Breakers | Length (mm) | Unit Width | |||||||
| XTPAXCLKB2D | 2 | 119 | 55 + 9 | ||||||
| XTPAXCLKB3D | 3 | 183 | 55 + 9 | ||||||
| XTPAXCLKB4D | 4 | 247 | 55 + 9 | ||||||
|
For motor-protective circuit-breakers/starters each with an auxiliary contact and trip-indicating auxiliary contact fitted on the right, or a voltage release fitted on the left. |
|||||||||
|
|
|||||||||
| Circuit Breakers | Length (mm) | Unit Width | |||||||
| XTPAXCLKC2D | 2 | 128 | 55 + 18 | ||||||
| XTPAXCLKC4D | 4 | 274 | 55 + 18 | ||||||
|
Shroud for unused terminals |
|||||||||
|
|
|||||||||