Type 1 enclosed breakers are designed for use in commercial buildings, apartment buildings and other areas where a general purpose enclosure is applicable. The breaker is front operable and is capable of being padlocked in either the ON or OFF position. Ratings through 1200 amperes are listed with Underwriters Laboratories as approved for service entrance application. Both surface and flush mounted enclosures are available.
This general purpose outdoor service center employs a circuit breaker inside a weatherproof sheet steel breaker enclosure to serve as a main disconnect and protective device for feeder circuits. Ratings through 1200 amperes are listed by Underwriters Laboratories as suitable for service entrance application.
The Type 12 enclosure is designed in line with specifications for special industry applications where unusually severe conditions involving oil, coolant, dust and other foreign materials exist in the operating atmosphere. The handle padlocks in the OFF position and the cover is interlocked with the handle mechanism to prevent opening the cover with the circuit breaker in the ON position. Ratings through 1200 amperes are listed by Underwriters Laboratories as suitable for service entrance application.
|
Breaker
Frame Amperes |
Enclosure
Type Class |
Part
Number |
|
FG
15–225 |
Type 1 | SFDN225 |
| Type 3R | RFDN225 | |
| Type 12 | JFDN225 | |
|
JG
175–250 |
Type 1 | SJDN250 |
| Type 3R | RJDN250 | |
| Type 12 | JJDN250 | |
|
KG
300–400 |
Type 1 | SKDN400 |
| Type 3R | RKDN400 | |
| Type 12 | JKDN400 | |
|
LG
450–600 |
Type 1 | SLDN600 |
| Type 3R | RLDN600 | |
| Type 12 | JLDN600 | |
|
NG
700–1200 |
Type 1 | SNDN1200 |
| Type 3R | RNDN1200 | |
| Type 12 | JNDN1200 |
|
Breaker
Frame |
Max. Amp
Rating |
AWG Wire
Range |
Metric Wire
Range mm 2 |
Part
Number |
| FG | 100 | 14–1/0 | 2.5–50 | 3T100FB (1) |
| FG | 150 | 4–4/0 | 25–95 | 3TA225FD (1) |
| JG | 250 | 4–350 kcmil | 25–185 | TA250KB |
| KG | 350 | 250–500 kcmil | 120–240 | TA350K |
| KG | 400 | 3/0–250 kcmil (2) | 95–120 | 3TA400K (1) |
| LG | 600 | 250–500 kcmil (2) | 120–240 | 3TA603LDK |
| NG | 700 | 1–500 kcmil (2) | 50–300 | TA700NB1 |
| NG | 1000 | 3/0–400 kcmil (3) | 95–185 | TA1000NB1 |
| NG | 1200 | 4/0–500 kcmil (4) | 120–300 | TA1200NB1 |
|
Max. Enclosure
Rating (Amperes) |
Main Lug Number
Size Cu/A |
Ground Lug
Size Cu/Al |
Part
Number |
| 100 | (1) 14–1/0 | (1) 14–1/0 | INK100 |
| 250 | (1) 6–350 kcmil | (1) 4–300 kcmil | INK250 |
| 400 |
(1) 4–750 kcmil or
(2) 1/0–250 kcmil |
(1) 4–300 kcmil | INK400 |
| 600 | (2) 250–500 kcmil | (1) 4–300 kcmil | INK600 |
| 1200 |
(3) 1/0 to 750 kcmil or
(4) 1/0 to 750 kcmil |
(1) 6–250 kcmil | INK1200 |
|
Breaker
Frame |
Factory
Mounted |
1A-1B | 2A-2B | |
| Field Kit |
Factory
Mounted |
Field Kit | ||
| FG (3) | A06 | A1X1PK | A13 | A2X1RPK |
| JG | A06 | A1X2PK | A13 | A2X2PK |
| KG | A06 | A1X3PK | A13 | A2X3PK |
| LG | A06 | A1X4PK | A13 | A2X4PK |
| NG | A06 | A1X5PK | A13 | A2X5PK |
|
Breaker
Frame |
Rating |
Factory
Mounted |
Field Kit |
| FG (3) | 12–24 Vdc | S02 | SNT1LP03K |
| JG | 12–24 Vdc | S02 | SNT2P04K |
| KG | 12–24 Vdc | S02 | SNT3P04K |
| LG | 12–24 Vdc | S02 | SNT4LP03K |
| NG | 12–24 Vdc | S02 | SNT5LP03K |
NOTES:
(1) Package of three terminals.
(2) Other accessories are available. Same as standard frame breakers.
(3) Field installation on the FG Frame is not UL listed.