Moeller N6-160
Molded Case Disconnect Switch

Return to the N6 Index

Maximum HP Rating 3 phase at: Continuous Current Rating
HP@230V HP@460V
60 100 150
N6 disconnect switches are UL recognized (UL 508) and CSA certified (C22.2 Nr. 14) as 3 pole, HP rated, non-automatic manual motor disconnects without any overload or short circuit tripping element. The switching mechanism has 3 positions (OFF, ON, +”tripped”) and they can be equipped with voltage trip accessories, such as shunt trip and undervoltage trip coils.

N6-160 Complete Part Number List

093283 N6-160 Disconnect Switch
034789 N6-160/ Disconnect Switch
032132 N6-160/I Disconnect Switch
079625 N6-160/I43/R Disconnect Switch
027420 N6-160/I43-G Disconnect Switch
065388 N6-160/I44/M Disconnect Switch
081999 N6-160/I44/R Disconnect Switch
098029 N6-160-EA Disconnect Switch
012602 N6-160-V Disconnect Switch
074846 N6-160-V/I Disconnect Switch
 

Shown above are the  N6-63, N6-100, N6-160 Disconnect switches.
All 3 are the exact same case size so replacing and upgrading is a snap!


When purchasing the N6-160, you will need the full number off the label as shown
by the red arrow (label color may vary) example: N6-160

Standard Breakers have 3 power wires in (L1-L2-L3) on the top, and 3 power wires out (T1-T2-T3) on the bottom.

Any other control wires will indicate some sort of modification accessory is installed!

By UL code breakers can only be modified at our UL Approved service facilities.
They cannot be installed in the field or by distributors. In order to get the correct breaker to you, it is imperative that we have the correct information due to the wide variety of options that may be installed on your current breaker.

Accessories can be identified by small labels on the breaker, with part numbers such as

a.                   (u-nzm6) (230, 60) Indicates under voltage trip which needs 230 volt 60hz applied to turn the breaker on.

b.                   (a-nzm6) (230,60) Indicates shunt trip which needs 230 volt 60hz applied to turn the breaker off.

c.                   (rhi, nhi, ahi -xx) Would be auxiliary contacts.

 If the labels cannot be read or to double check their usage record all the terminal numbers that have control wires on them, and your KMparts  Specialist will advise you of your best options.

 Please note any of the above when ordering. Also check to see if they are even used. If they are present but there are no wires on them then chances are you don’t need them.