Pardon our appearance - site updates are in progress. 
(866) 595-9616
Same Day Shipping | Authorized Eaton, Moeller, & Cutler-Hammer Distributor
sales@kmparts.com

EATON 30 mA Ground Fault (Earth Leakage) Module

30 mA Ground Fault (Earth Leakage) Module

Product Description

Eaton offers a three- and four pole 30 mA ground fault (earth leakage) protection module for Series G E-, J- and L-Frame breakers. UL-listed modules are available for E, J and L molded case circuit breakers (MCCBs). The modules are bottom mounted for circuits up to 125A (E-Frame) 160 and 250 amperes (J-Frame), or 400 and 630 amperes for the L-Frame.

The module is completely selfc ontained because the current sensor, relay and power supply are located inside the product. Current pickup settings are selectable from 0.03–10 amperes for all IEC-rated modules and E and J UL-listed module, and 0.03– 30 amperes for the L ULlisted modules. Time delays are also selectable from Instantaneous–1.0 seconds for 0.10 ampere settings and above. A current pickup setting of 0.03 amperes defaults to an Instantaneous time setting regardless of the time dial’s position. Two alarm contacts come as standard: a 50% pretrip and a 100% after trip, both based only on earth leakagecurrent levels.

UL-Rated LG-Frame Earth Leakage Module Faceplate

UL Earth-Leakage-Module-Faceplate

IEC-Rated LG-Frame Earth Leakage Module Faceplate

IEC Earth-Leakage-Module-Faceplate

EG-Frame Ground Fault Modules, UL-Rated (Bottom Mounted, 120–480 Vac, 50/60 Hz) (1)

Ampere
Rating
Number of
Poles
Part
Number
125 3 ELEBN3125G
125 4 ELEBN4125G

EG-Frame Earth Leakage Modules, IEC-Rated (Bottom Mounted, 230–415 Vac, 50/60 Hz)

Ampere
Rating
Number of
Poles
Part
Number
125 3 ELEBE3125G
125 4 ELEBE4125G

JG-Frame Ground Fault Modules, UL-Rated (Bottom Mounted, 120–480 Vac, 50/60 Hz)

Ampere
Rating
Number of
Poles
Part
Number
150 3 ELJBN3150W
150 4 ELJBN4150W
250 3 ELJBN3250W
250 4 ELJBN4250W

JG-Frame Earth Leakage Modules, IEC-Rated (Bottom Mounted, 230–415 Vac, 50/60 Hz)

Ampere
Rating
Number of
Poles
Part
Number
160 3 ELJBE3160W
160 4 ELJBE4160W
250 3 ELJBE3250W
250 4 ELJBE4250W

LG-Frame Ground Fault Modules, UL-Rated (Bottom Mounted, 120–480 Vac, 50/60 Hz)

Ampere
Rating
Number of
Poles
Part
Number
400 3 ELLBN3400W
400 4 ELLBN4400W
600 3 ELLBN3600W
600 4 ELLBN4600W

LG-Frame Earth Leakage Modules, IEC-Rated (Bottom Mounted, 230–415 Vac, 50/60 Hz)

Ampere
Rating
Number of
Poles
Part
Number
400 3 ELLBE3400W
400 4 ELLBE4400W
630 3 ELLBE3630W
630 4 ELLBE4630W

NOTES:
(1) Shunt trip and undervoltage release cannot be used in an EG breaker connected to an earth leakage module.