Eight inputs, four relay or transistor outputs. In all the DC versions, there is the option of two analog inputs. The easy500 has three contacts and one coil for circuit configuration in each of up to 41 lines of logic.
|
|
8 digital inputs |
|
16 operating and message texts |
|
Models available with 4
digital relay outputs
or 4 transistor outputs |
|
2 analog inputs (10-bit)
optional (not with 230 V AC) |
|
|
128 rungs of 3 contacts
and 1 coil each |
|
2/2 high-speed inputs, 1
kHz
(only DC devices) |
EASY 500 basic units |
|||||
| Basic Model with Display and NO Clock | 512-AC-R | 512-DC-R | |||
| Basic Model with Display and Clock | 512-AB-RC | 512-AC-RC | 512-DA-RC | 512-DC-RC | 512-DC-TC |
| Basic Model with Clock and NO Display | 512-AB-RX | 512-AC-RCX | 512-DA-RCX | 512-DC-RCX | 512-DC-TCX |
| Supply voltage |
24 VAC
|
100 – 240 VAC
|
12 VDC
|
24 VDC |
|
| Heat dissipation |
5 V A
|
2 W
|
|||
| Inputs, digital |
8
|
8
|
8
|
8
|
8
|
|
Inputs,
analog 0 – 10 V (optional) |
Up to
2
of the provided
8
inputs may
be user assigned as analog inputs
|
–
|
Up to 2 of the provided 8 inputs may be user assigned as analog inputs | ||
| Outputs, digital |
4
Relay
|
4
Relay
|
4
Relay
|
4
Relay
|
4
Transistor
|
|
Outputs,
analog (0 – 10 V) |
–
|
–
|
–
|
–
|
–
|
| Continuous current outputs |
8 A
|
8 A
|
8 A
|
8 A
|
0.5 A
|
|
Short-circuit proof with
power factor 1 |
Line protection B 16, 600 A |
– | |||
| Short-circuit proof with power factor 0.7... 0.7 |
Line protection B 16, 900 A |
– | |||
| Dimensions |
2.85 x 3.5 x 2.30 in (W x H x D)
|
||||
Purchase your easy500 Today!