Moeller DIL00M-DIL2M |
|||
PART # | CONTACTOR FOR USE ON | DESCRIPTION | FUNCTION |
RCBDIL48 | DIL00AM, DIL00M, DIL0AM, DIL0M, DIL1AM, DIL1M, DIL2AM, DIL2M | RC Suppressors | For AC operated contactors, 50 – 60 Hz. Drop-out delay should be taken into consideration. |
RCBDIL250 | |||
RCBDIL415 | |||
VGBDIL24 | DIL00AM, DIL00M, DIL1AM, DIL1M, DIL2AM, DIL2M | Varistor Suppressors | For AC operated contactors, 50 – 60 Hz, (DIL00M to DIL4M115) and DC operated contactors (DIL00M-G to DIL2AM-G). DC operated contactors DIL3M80 to DIL4M115 have an integrated varistor suppressor as standard. |
VGBDIL48 | |||
VGBDIL250 | |||
VGBDIL415 | |||
VGCDIL24 | DIL00AM, DIL00M, DIL0AM, DIL0M, DIL1AM, DIL1M, DIL2AM, DIL2M | Suppressors | For DC operated and AC operated contactors DIL00M to DIL2AM |
VGCDIL48 | |||
VGCDIL250 | |||
VGCDIL415 | |||
FDBDIL | DIL00M, DIL00AM, DIL0M, DIL0AM, DIL1AM, DIL1M, DIL2AM, DIL2M | Free-wheel diode suppressor | For DC operated contactors. Drop-out delay should be taken into consideration. |
S1DIL00M | DIL00M & DIL00AM | STAR BRIDGE |
SOLID JUMPER THAT CONNECTS ALL 3 POWER POLES TOGETHER. HAS NO INCOMING WIRE TERMINAL CONNECTIONS. |
S1DIL0M | DIL0M & DIL0AM | ||
S1DIL1M | DIL1M & DIL1AM | ||
S1DIL2M | DIL2M & DIL2AM | ||
S1DIL3M | DIL3M80 | ||
S1DIL4M | DIL4M115 | ||
DILM400-XS1 | DILM185-DILM400 | ||
DILM500-XS1 | DILM500 | ||
P1DIL00M | DIL00M & DIL00AM | PARALLELING BRIDGE |
SOLID JUMPER THAT CONNECTS ALL 3 POWER POLES TOGETHER AND HAS A SINGLE INCOMING TERMINAL CONNECTION. |
P1DIL0M | DIL0M & DIL0AM | ||
P1DIL1M | DIL1M & DIL1AM | ||
P1DIL2M | DIL2M & DIL2AM | ||
MVS-WB-00M | DIL00(A)M | REVERSING JUMPER KIT
(1) MVDILM-Mechanical Interlock. Must be purchased separately |
Consisting of one 3 pole paralleling link (top) and reversing link with A2 coil bridge (bottom). To form a reversing contactor. An overload module cannot be directly connected to the contactor and if needed must be mounted remotely. |
MVS-WB5MV | DIL00(A)M+MVDILM (1) | ||
MVS-WB-0M | DIL0(A)M | ||
MVS-WB-11MV | DIL0(A)M+MVDILM (1) DIUL0(A)M/MV |
||
MVS-WB-1M | DIL1(A)M DIUL1(A)M |
||
BT480 | All top mounting auxiliary contacts | Paralleling Links | Not insulated. Standard Quantity: 100 |
MVDILM | DIL00(A)M, DIL0(A)M, DIL1(A)M, DIL2(A)M | MECHANICAL INTERLOCK KIT | For providing mechanical interlock between 2 contactors. No side mount auxiliary contacts may be used except on the opposite sides of the MV module. |
ZKDIL0M | DIL0AM, DIL0M | Control Circuit Terminals | Pressure wire connectors mounted directly
to the main terminals for control circuit tap-off. 15A, 600V max., AWG 18 - 14 |
ZKDIL1M | DIL1AM, DIL1M DIL2AM, DIL2M |
||
HKDILM | DIL1AM, DIL1M DIL2AM, DIL2M |
Main Terminal | For connecting large cross-sections, For connection of: up to 50 mm2 stranded or 35 mm2 flexible with ferrule |
V0DIL | DIL00M, DIL00AM, DIL0AM, DIL0M, DIL1AM, DIL1M, DIL2AM, DIL2M | Coupling Connector |
0 mm distance between contactors |
V5/15DIL | 5mm between contactors, for contactors with DC coil 15mm between contactors, for mechanical interlock between contactors. | ||
V10/A5DIL | 10mm between contactors, for mounting one side mounting auxiliary contact between two contactors 5mm between contactors for contactors with DC coil without permanent connection. | ||
CS-TE | ETS4-VS3 | For screw mounting of ETS4-VS3 | |
TPE11DIL | DIL00M-DIL2AM | Top Mount ON Delay Timer | Snaps on the top of the contactor and provided (1) Normally Open and (1) Normally Closed Timed Contact. Adjustment ranges either (0.2-30) or (20-180) seconds. |
TPD11DIL | DIL00M-DIL2AM | Top Mount OFF Delay Timer | |
V-GDIL (24vdc) |
DIL00M | Top Mount Latching Module | With addition of this module a standard DIL00M becomes a Latching relay. Pulse the DIL00M coil to Latch and pulse the module coil to UNLATCH. |
V-DIL (120VAC) |
DIL00M | ||
NDIL0M | DIL0M | 4th Power Pole. Adding this module to a standard 3 pole contactor makes it a 4 Pole Power contactor | Continuous Rating Open 35 Amps.
Continuous Rating Closed 30 Amps. |
NDIL1M | DIL1M | Continuous Rating Open 55 Amps.
Continuous Rating Closed 44 Amps. |
|
NDIL2M | DIL2M | Continuous Rating Open 75 Amps.
Continuous Rating Closed 60 Amps. |
|
BT483 | DILEM DIL00M to DILM820 |
Connection tabs for fast-on connectors | For auxiliary contact and coil connections. Use connectors with insulated sleeves. Standard quantity: 100 |
PL-DILT | TPE11DIL TPD11DIL |
Sealable Shrouds | Cover is fastened via a screw. Sealable to prevent access. |
XGKA-U | Universal Mounting Adapter | Mounting: |
|
VS1DIL | DIL00M-DIL2AM | Contactor Mounted incoming voltage interface module with integral suppressor circuit. | For energizing of the contactor from low level 24 vdc inputs. The VS1 and VS2 plug directly onto the DILM coil terminals |
VS2DIL | Contactor Mounted incoming voltage interface module with out integral suppressor circuit. | ||
ETS4-VS3 | Any Contactor
with less than 2 amp coil |
SEPARATE
DIN RAIL MOUNT |
For energizing of the contactor from low level 24 vdc inputs. |
Click here for Legacy Contactor Catalog Pages |
© 2016 KMParts.com, Inc. All rights reserved.