Menu


Moeller DIL00M-DIL2M
Accessories

PART # CONTACTOR FOR USE ON DESCRIPTION FUNCTION
RCBDIL48 DIL00AM, DIL00M, DIL0AM, DIL0M, DIL1AM, DIL1M, DIL2AM, DIL2M RC Suppressors For AC operated contactors, 50 – 60 Hz.
Drop-out delay should be taken into
consideration.
RCBDIL250
RCBDIL415
 
VGBDIL24 DIL00AM, DIL00M, DIL1AM, DIL1M, DIL2AM, DIL2M Varistor Suppressors For AC operated contactors, 50 – 60 Hz,
(DIL00M to DIL4M115) and DC operated
contactors (DIL00M-G to DIL2AM-G).
DC operated contactors DIL3M80 to
DIL4M115 have an integrated varistor
suppressor as standard.
VGBDIL48
VGBDIL250
VGBDIL415
 
VGCDIL24 DIL00AM, DIL00M, DIL0AM, DIL0M, DIL1AM, DIL1M, DIL2AM, DIL2M Suppressors For DC operated and AC operated contactors
DIL00M to DIL2AM
VGCDIL48
VGCDIL250
VGCDIL415
 
FDBDIL DIL00M, DIL00AM, DIL0M, DIL0AM, DIL1AM, DIL1M, DIL2AM, DIL2M Free-wheel diode suppressor For DC operated contactors. Drop-out delay should be taken into consideration.
 
S1DIL00M DIL00M & DIL00AM STAR BRIDGE
SOLID JUMPER THAT CONNECTS ALL 3 POWER POLES TOGETHER. HAS NO INCOMING WIRE TERMINAL CONNECTIONS.
S1DIL0M DIL0M & DIL0AM
S1DIL1M DIL1M & DIL1AM
S1DIL2M DIL2M & DIL2AM
S1DIL3M DIL3M80
S1DIL4M DIL4M115
DILM400-XS1 DILM185-DILM400
DILM500-XS1 DILM500
 
P1DIL00M DIL00M & DIL00AM PARALLELING BRIDGE
SOLID JUMPER THAT CONNECTS ALL 3 POWER POLES TOGETHER AND HAS A SINGLE INCOMING TERMINAL CONNECTION.
P1DIL0M DIL0M & DIL0AM
P1DIL1M DIL1M & DIL1AM
P1DIL2M DIL2M & DIL2AM
 
MVS-WB-00M DIL00(A)M REVERSING JUMPER KIT

(1) MVDILM-Mechanical Interlock.

 Must be purchased separately

Consisting of one 3 pole paralleling link (top) and reversing link with A2 coil bridge (bottom). To form a reversing contactor. An overload module cannot be directly connected to the contactor and if needed must be mounted remotely.
MVS-WB5MV DIL00(A)M+MVDILM (1)
MVS-WB-0M DIL0(A)M
MVS-WB-11MV DIL0(A)M+MVDILM (1)
DIUL0(A)M/MV
MVS-WB-1M DIL1(A)M
DIUL1(A)M
 
BT480 All top mounting auxiliary contacts Paralleling Links Not insulated. Standard Quantity: 100
 
MVDILM DIL00(A)M, DIL0(A)M, DIL1(A)M, DIL2(A)M MECHANICAL INTERLOCK KIT For providing mechanical interlock between 2 contactors. No side mount auxiliary contacts may be used except on the opposite sides of the MV module.
 
ZKDIL0M DIL0AM, DIL0M Control Circuit Terminals Pressure wire connectors mounted directly to the main
terminals for control circuit tap-off.
15A, 600V max., AWG 18 - 14
ZKDIL1M DIL1AM, DIL1M
DIL2AM, DIL2M
 
HKDILM DIL1AM, DIL1M
DIL2AM, DIL2M
Main Terminal For connecting large cross-sections,
For connection of:
up to 50 mm2 stranded
or 35 mm2 flexible with ferrule
 
V0DIL DIL00M, DIL00AM, DIL0AM, DIL0M, DIL1AM, DIL1M, DIL2AM, DIL2M Coupling
Connector
0 mm distance between contactors
V5/15DIL 5mm between contactors, for contactors with DC coil 15mm between contactors, for mechanical interlock between contactors.
V10/A5DIL 10mm between contactors, for mounting one side mounting auxiliary contact between two contactors 5mm between contactors for contactors with DC coil without permanent connection.
CS-TE ETS4-VS3 For screw mounting of ETS4-VS3
 
TPE11DIL DIL00M-DIL2AM Top Mount ON Delay Timer Snaps on the top of the contactor and provided (1) Normally Open and (1) Normally Closed Timed Contact. Adjustment ranges either (0.2-30) or (20-180) seconds.
TPD11DIL DIL00M-DIL2AM Top Mount OFF Delay Timer
V-GDIL
(24vdc)
DIL00M Top Mount Latching Module With addition of this module a standard DIL00M becomes a Latching relay. Pulse the DIL00M coil to Latch and pulse the module coil to UNLATCH.
V-DIL
(120VAC)
DIL00M
 
NDIL0M DIL0M 4th Power Pole. Adding this module to a standard 3 pole contactor makes it a 4 Pole Power contactor Continuous Rating Open 35 Amps.

Continuous Rating Closed 30 Amps.

NDIL1M DIL1M Continuous Rating Open 55 Amps.

Continuous Rating Closed 44 Amps.

NDIL2M DIL2M Continuous Rating Open 75 Amps.

Continuous Rating Closed 60 Amps.

 
BT483 DILEM
DIL00M to DILM820
Connection tabs for fast-on connectors For auxiliary contact and coil connections. Use connectors with insulated sleeves. Standard quantity: 100
 
PL-DILT TPE11DIL
TPD11DIL
Sealable Shrouds Cover is fastened via a screw. Sealable to prevent access.
 
XGKA-U   Universal Mounting Adapter

Mounting:
Self Adhesive
with M3 screw or
cable tie Standard Quantity: 250

 
VS1DIL DIL00M-DIL2AM Contactor Mounted incoming voltage interface module with integral suppressor circuit. For energizing of the contactor from low level 24 vdc inputs. The VS1 and VS2 plug directly onto the DILM coil terminals
VS2DIL Contactor Mounted incoming voltage interface module with out  integral suppressor circuit.
ETS4-VS3 Any Contactor

with less than 2 amp coil

SEPARATE

 DIN RAIL MOUNT

For energizing of the contactor from low level 24 vdc inputs.
 

Click here for Current Contactor Catalog Pages

Click here for Legacy Contactor Catalog Pages

Let our expert sales staff guide you through finding the right products to fit your needs. CALL 866-595-9616.