NZM10-600N
Molded Case Circuit Breaker

Normal Interrupting Capacity


NZM10-600N
Switch Blocks - 600A, 600 V AC

TYPE

ARTICLE NUMBER

 

Switch Block Ratings
Continuous Current

NZM10-600N-NA

Switch Block

Suitable For Insertion Of Trip Modules

NZM10-600N switch blocks make up a complete breaker minus the protective trip module.  See trip module data to complete the break assembly.

600

n Supplied with toggle operator.  n Supplied with bolt on connection as standard. 


NZM10-600N
Fixed Thermal Adjustable Magnetic Inverse Time Circuit Breakers
600 A, 600 V AC

Type
Article Number

Long Time Response
Current Setting
Adjustable Instantaneous
Pick-Up Setting

Adjustable Short Tome Delay Pick Up Setting For Selectivity In Networks

 

Time Delay Range

 0-1000 ms

Delayed

NZM10-600N/ZMVA-500-NA 500 1000-9000 2 - 12 x Ir
NZM10-600N/ZMVA-600-NA 600

n Supplied with toggle operator.  n Supplied with bolt on connection as standard. 


NZM10-600N
Adjustable Thermal Inverse Time Circuit Breakers
600 A, 600 V AC

Type
Article Number

Long Time
Response
Current Setting
Adjustable
Instantaneous
Pick-Up
Setting
NZM10-600N/ZM-600-NA 300 - 600 600 - 7200

n Supplied with toggle operator.  n Supplied with bolt on connection as standard. 


NZM10-600N
Adjustable Thermal Magnetic Inverse Time Circuit Breakers
600 A, 600 V AC

Type
Article Number

Long Time Response Current
Setting

Adjustable Instantaneous
Pick-Up Setting

 

Adjustable Short Tome Delay Pick Up Setting For Selectivity In Networks

 

Time Delay Range

 0-1000 ms

Delayed

NZM10-600N/ZMV-600-NA

300 - 600 1000-9000 600 - 7200

n Supplied with toggle operator.  n Supplied with bolt on connection as standard. 


NZM10-600N
Adjustable Thermal Inverse Time Circuit Breakers
600 A, 600 V AC

Type NZM10...(N)(S)/ZM(A)-...-NA molded case circuit breakers are UL listed (UL 489) and CSA certified (22.2 No. 5.1) Inverse time, Solid State Trip Circuit Breakers with a fixed or adjustable long time response and adjustable instantaneous pick-up range.

Type NZM10-...H/ZM(A)-...-NA molded case circuit breakers are UL listed (UL489) and CSA certified (22.2 No. 5.1) Current-limiting Inverse Time, Solid State Trip Circuit Breakers with a fixed or adjustable long time response and adjustable instantaneous pick-up range.

Type
Article Number

Long Time
Response
Current
Settings

Adjustable
Instantaneous
Pick-Up
Setting

NZM10-600N/ZMA-500-NA

500 1000 - 6000

NZM10-600N/ZMA-600-NA

600 1200 - 7200

n Supplied with toggle operator.     n Supplied with bolt on connection as standard.


NZM10-600-N
MOLDED CASE SWITCH - 600A, 600 V AC

TYPE

ARTICLE NUMBER

AMPERE RATING

NZM10-600 N/B-NA

630

n Supplied with toggle operator.     n Supplied with bolt on connection as standard.

These switches are virtually identical in construction to the NZM10 molded case circuit breakers except that they are manual, non-automatic switches without any overload or over current protective features. They are equally rates up to 600A. All molded-case switches are UL listed (UL 489) and CSA certified (C22.2 Nr. 5.2), in conformity with IEC/EN 60 947-3 (switch disconnectors) and CE marked.

Molded case Switches are tested to determine their acceptability for continuous operation at their marked rated load. In addition, they are tested at six times their full ampere rating to cover motor circuit applications and are suitable for use as motor circuit disconnects per NEC section 430-109 and CEC section 28-602.


NZM10-600-N
MOLDED CASE CIRCUIT BREAKERS
INSTANTANEOUS TRIP TYPE, 600A

Type
Article Number
Circuit Breaker Continuous Current
Rating
Adjustable
Instantaneous
Trip Response Range
NZM10-600N/ZM-600-OBI-CNA

600V AC, UL/SCA
NORMAL LEVEL SHORT CIRCUIT RATING
Supplied with toggle operator.
Supplied standard with bolt on   connection.
 

600 1200 ... 7200

n Supplied with toggle operator.     n Supplied with bolt on connection as standard.


Return to NZM10