Eaton
|
|
![]() |
Series-C Frame Size - R Part Index CLICK HERE |
Type R (3-Pole) Shown |
Number of Poles |
Amperes | Interrupting Capacity |
Terminals |
---|---|---|---|
4 | 2000 | — | Includes B2016RDL rear connectors. |
Notes:
Molded case switch may trip above 17,500 amperes.
UL 489/CSA Interrupting Capacity Ratings(1) | |||||
Circuit Breaker Type |
Number of Poles |
Interrupting Capacity (kA
Symmetrical Amperes) Volts AC (50/60 Hz) |
|||
---|---|---|---|---|---|
240 | 277 | 480 | 600 | ||
RD | 3, 4 | 125 | — | 65 | 50 |
CRD(2) | 3 | 125 | — | 65 | 50 |
RDC | 3, 4 | 200 | — | 100 | 65 |
CRDC(2) | 3 | 200 | — | 100 | 65 |
IEC 947-2 Interrupting Capacity Ratings(1) | ||||
Circuit Breaker Type |
Number of Poles |
Interrupting Capacity (kA
Symmetrical Amperes) Volts AC (50/60 Hz) |
||
---|---|---|---|---|
240 | 415 | 690 | ||
RD | ||||
Icu | 3, 4 | 135 | 70 | 25 |
Ics | 3, 4 | 100 | 50 | 13 |
RDC | ||||
Icu | 3, 4 | 200 | 100 | 35 |
Ics | 3, 4 | 100 | 50 | 18 |
NOTES:
(1) Utilization Category A circuit breakers.
(2) 100% rated breakers.
Trip Unit Type | Digitrip RMS 510 |
Digitrip RMS 610 |
Digitrip RMS 810 |
Digitrip RMS 910 |
Digitrip OPTIM 1050 |
---|---|---|---|---|---|
rms sensing | Yes | Yes | Yes | Yes | Yes |
Breaker Type | |||||
Frame | R | R | R | R | R |
Ampere range | 800–2500A | 800–2500A | 800–2500A | 800–2500A | 800–2500A |
Interrupting rating at 480 volts |
65, 100 (kA) | 65, 100 (kA) | 65, 100 (kA) | 65, 100 (kA) | 65, 100 (kA) |
Protection | |||||
Ordering options | LI, LS, LSI, LIG, LSG, LSIG |
LI, LS, LSI, LIG, LSG, LSIG |
LI, LS, LSI, LIG, LSG, LSIG |
LI, LS, LSI, LIG, LSG, LSIG |
LSI(A), LISG |
Fixed rated plug (In) | Yes | Yes | Yes | Yes | Yes |
Overtemperature trip | Yes | Yes | Yes | Yes | Yes |
Long Delay Protection (L) | |||||
Adjustable rating plug (In) |
No | No | No | No | No |
Long delay pickup |
0.5–1.0 x (In) | 0.5–1.0 x (In) | 0.5–1.0 x (In) | 0.5 –1.0 x (In) | 0.4–1.0 x (In) |
Long delay time I2t |
2–24 seconds | 2–24 seconds | 2–24 seconds | 2–24 seconds | 2–24 seconds |
Long delay time I4t |
No | No | No | No | 1–5 Seconds |
Long delay thermal memory |
Yes | Yes | Yes | Yes | Yes |
High load alarm |
No | 0.85 x Ir | 0.85 x Ir | 0.85 x Ir | 0.5-1.0 x Ir |
Short Delay Protection (S) | |||||
Short delay pickup |
200–600% S1 and S2 x (Ir) |
200–600% S1 and S2 x (Ir) |
200–600% S1 and S2 x (Ir) |
200–600% S1 and S2 x (Ir) |
150-800% x (Ir)(1)(2) |
Short delay time I2t |
100–500 ms | 100–500 ms | 100–500 ms | 100–500 ms | 100–500 ms |
Short delay time flat |
100–500 ms | 100–500 ms | 100–500 ms | 100–500 ms | 100–500 ms |
Short delay time zone selective interlocking |
Yes | Yes | Yes | Yes | Yes |
Instantaneous Protection (I) | |||||
Instantaneous pickup | 200–600% M1and M2 x (In) |
200–600% M1and M2 x (In) |
200–600% M1and M2 x (In) |
200–600% M1and M2 x (In) |
200–800% x (In)(2) |
Discriminator | Yes(3) | Yes(3) | Yes(3) | Yes(3) | Yes |
Instantaneous override | Yes | Yes | Yes | Yes | Yes |
Ground Fault Protection (G) | |||||
Ground fault alarm(4) |
No | No | No | No | 25–100% x (In) |
Ground fault pickup(4) |
25–100% x (Is) | 25-100% x (Is) | 25–100% x (Is) | 25–100% x (Is) | 25–100% x (In) |
Ground fault delay I2t |
100–500 ms | 100–500 ms | 100–500 ms | 100–500 ms | 100–500 ms |
Ground fault delay flat |
100–500 ms | 100–500 ms | 100–500 ms | 100–500 ms | 100–500 ms |
Ground fault zone selective interlocking |
Yes | Yes | Yes | Yes | Yes |
Ground fault thermal memory |
Yes | Yes | Yes | Yes | Yes |
System Diagnostics | |||||
Status LEDs | Yes | Yes | Yes | Yes | Yes |
Cause of trip LEDs |
Yes | Yes | Yes | Yes | Yes |
Magnitude of trip information |
No | Yes | Yes | Yes | Yes |
Remote signal contacts | No | Yes | Yes | Yes | Yes |
System Monitoring | |||||
Digital display | No | Yes | Yes | Yes | Yes(5) |
Current | No | Yes | Yes | Yes | Yes |
Voltage | No | No | No | Yes | No |
Power and energy |
No | No | Yes | Yes | Yes |
Power quality—harmonics | No | No | No | Yes | Yes |
Power factor |
No | No | Yes (over Eaton PowerNet only) |
Yes | Yes |
Communications | |||||
Eaton PowerNet |
No | No | Yes | Yes | Yes |
Testing | |||||
Testing method | Integral | Integral | Integral | Integral | OPTIMizer, BIM, PowerNet |
NOTES: |
Notes: |
![]() |
Number of Poles | Width | Height | Depth |
---|---|---|---|
3 | 15.50 (393.7) | 16.00 (406.4) | 9.75 (247.7) |
4 | 20.00 (508.0) | 16.00 (406.4) | 9.75 (247.7) |