Eaton Klockner Moeller LEGACY OVERLOAD RELAYS

KMParts
Eaton/Moeller Authorized Distributor
Z00-Series
Limited Stock
Z1-Series
Limited Stock
Z5-Series
Limited Stock
Z5-Series
For Seperate MountingLimited Stock

ZW7-Series
Limited StockBUY HERE
1.866.595.9616
International Calls
+001.941.473.0073
CALL
KMParts
Eaton/Moeller Authorized DistributorZ00-Series
Limited StockZ1-Series
Limited StockZ5-Series
Limited StockZ5-Series
For Seperate MountingZW7-Series
Limited StockAdjustable Range | Auxiliary contacts | For use with | Short-Circuit protection | Part Number | ||
by fuses | by circuit breaker | |||||
N.O. | N.C. | max. 600V AC Amp | max. 600V AC Amp | |||
0.1 - 0.16 | 1 | 1 | DIL00M DIL00AM DIL0M DIL0AM |
1 | 25 | Z00-0.16 |
0.16 - 0.24 | 1 | 1 | 1 | 25 | Z00-0.24 | |
0.24 - 0.4 | 1 | 1 | 1 | 25 | Z00-0.4 | |
0.4 - 0.6 | 1 | 1 | 1 | 25 | Z00-0.6 | |
0.6 - 1 | 1 | 1 | 3 | 25 | Z00-1 | |
1 - 1.6 | 1 | 1 | 6 | 25 | Z00-1.6 | |
1.6 - 2.4 | 1 | 1 | 6 | 25 | Z00-2.4 | |
2.4 - 4 | 1 | 1 | 15 | 25 | Z00-4 | |
4 - 6 | 1 | 1 | 20 | 25 | Z00-6 | |
6 - 10 | 1 | 1 | 40 | 25 | Z00-10 | |
10 - 16 | 1 | 1 | 60 | 30 | Z00-16 | |
16 - 24 | 1 | 1 | 90 | 30 | Z00-24 |
Adjustable Range | Auxiliary contacts | For use with | Short-Circuit protection | Part Number | ||
by fuses | by circuit breaker | |||||
N.O. | N.C. | max. 600V AC Amp | max. 600V AC Amp | |||
6 - 10 | 1 | 1 | DIL1M DIL1AM DIL2M DIL2AM |
40 | 40 | Z1-10 |
10 - 16 | 1 | 1 | 60 | 60 | Z1-16 | |
16 - 24 | 1 | 1 | 90 | 90 | Z1-24 | |
24 - 40 | 1 | 1 | 125 | 125 | Z1-40 | |
40 - 57 | 1 | 1 | 200 | 150 | Z1-57 | |
50 - 63 | 1 | 1 | 200 | 150 | Z1-63 | |
63 - 75 | 1 | 1 | 250 | 200 | Z1-75 |
Adjustable Range | Auxiliary contacts | For use with | Short-Circuit protection | Part Number | ||
by fuses | by circuit breaker | |||||
N.O. | N.C. | max. 600V AC Amp | max. 600V AC Amp | |||
25 - 35 | 1 | 1 | DIL3M80 | 125 | 125 | Z5-35/SK3 |
35 - 50 | 1 | 1 | 225 | 200 | Z5-50/SK3 | |
50 - 70 | 1 | 1 | 250 | 250 | Z5-70/SK3 | |
70 - 100 | 1 | 1 | 400 class J | 400 | Z5-100/SK3 | |
35 - 50 | 1 | 1 | DIL4M115 | 225 | 200 | Z5-50/SK4 |
50 - 70 | 1 | 1 | 250 | 250 | Z5-70/SK4 | |
70 - 100 | 1 | 1 | 400 class J | 400 | Z5-100/SK4 | |
95 - 125 | 1 | 1 | 500 class J | 500 | Z5-125/SK4 | |
120 - 150 | 1 | 1 | 600 class J | 600 | Z5-150/SK4 | |
50 - 70 | 1 | 1 | DILM185 DILM225 DILM250 |
250 | 250 | Z5-70/FF250 |
70 - 100 | 1 | 1 | 400 class J | 400 | Z5-100/FF250 | |
95 - 125 | 1 | 1 | 500 class J | 500 | Z5-125/FF250 | |
120 - 160 | 1 | 1 | 600 class J | 600 | Z5-160/FF250 | |
160 - 220 | 1 | 1 | 800 class L | 800 | Z5-220/FF250 | |
200 - 250 | 1 | 1 | 700 class L | 600 | Z5-250/FF250 |
Adjustable Range | Auxiliary contacts | Short-Circuit protection | Part Number | ||
by fuses | by circuit breaker | ||||
N.O. | N.C. | max. 600V AC Amp | max. 600V AC Amp | ||
25 - 35 | 1 | 1 | 125 | 125 | Z5-35/KK3 |
35 - 50 | 225 | 200 | Z5-50/KK3 | ||
50 - 70 | 250 | 250 | Z5-70/KK3 | ||
70 - 100 | 400 class J | 400 | Z5-100/KK3 | ||
35 - 50 | 1 | 1 | 225 | 200 | Z5-50/KK4 |
50 - 70 | 250 | 250 | Z5-70/KK4 | ||
70 - 100 | 400 class J | 400 | Z5-100/KK4 | ||
95 - 125 | 500 class J | 500 | Z5-125/KK4 | ||
120 - 150 | 600 class J | 600 | Z5-150/KK4 | ||
50 - 70 | 1 | 1 | 250 | 250 | Z5-70/FF250 |
70 - 100 | 400 class J | 400 | Z5-100/FF250 | ||
95 - 125 | 500 class J | 500 | Z5-125/FF250 | ||
120 - 160 | 600 class J | 600 | Z5-160/FF250 | ||
160 - 220 | 800 class L | 800 | Z5-220/FF250 | ||
200 - 250 | 700 class L | 600 | Z5-250/FF250 |
Adjustable Range | Auxiliary contacts | Short-Circuit protection | Part Number | ||
by fuses | by circuit breaker | ||||
N.O. | N.C. | max. 600V AC Amp | max. 600V AC Amp | ||
42 - 63 | 1 | 1 | as required by associated contactor overload relay is self-protecting |
ZW7-63 | |
60 - 90 | ZW7-90 | ||||
85 - 125 | ZW7-125 | ||||
110 - 160 | ZW7-160 | ||||
160 - 240 | ZW7-240 | ||||
190 - 290 | ZW7-290 | ||||
270 - 400 | ZW7-400 | ||||
360 - 540 | ZW7-540 |