Motor Controller Enclosure
Section Table
(For Outdoor Use 1)

Provides a degree of protection against the following environmental conditions 3 3R 3S 4 4X 6 6P
Incidental contact with the enclosed equipment X X X X X X X
Rain, Snow and sleet X X X X X X X
Sleet* -- -- X -- -- -- --
Windblown Dust X -- X X X X X
Hose Down -- -- -- X X X X
Corrosive Agents -- -- -- X X -- X
Occasional Temporary Submersion -- -- -- -- X X X
Occasional Prolonged Submersion -- -- -- -- -- -- X

* mechanism shall be operable when ice covered.

Motor Controller Enclosure
Section Table
For Indoor Use

Enclosure Type Number 1)
Provides a degree of protection against the following environmental conditions 1 2 4 4X 5 6 6P 12 12K 13
Incidental contact with the enclosed equipment X X X X X X X X X X
Falling Dirt X X X X X X X X X X
Falling liquids and light splashing X X X X X X X X X X
Circulating dust, lint, fibers and flyings. -- -- X X -- X X X X X
Settling airborne dust, lint, fibers and flyings. -- -- X X X X X X X X
Hose down and splashing water. -- -- X X -- X X -- -- --
Oil and coolant seepage -- -- -- -- -- -- -- X X X
Oil or Coolant spraying and splashing. -- -- -- -- -- -- -- -- -- X
Corrosive Agents -- -- -- X -- -- X -- -- --
Occasional Temporary Submersion -- -- -- -- -- X X -- -- --
Occasional Prolonged Submersion -- -- -- -- -- -- X -- -- --

1) Enclosure type number shall be marked on the motor controller enclosure