For two contactors with AC or DC operated magnet systems.
Distance between Contactors = 0 mm.
Mechanical Lifespan = 2.5 x 106 operations.
Additional auxiliary contact modules can be fitted.
DILEM
DILM12-XMV
For two contactors with AC or DC operated magnet systems.
Distance between Contactors = 0 mm.
Mechanical Lifespan = 2.5 x 106 operations.
Additional auxiliary contact modules can be fitted.
For two contactors with the same or different magnetic
systems.
Mechanical lifespan 5 x 106 operations. No auxiliary contact
is possible
between the mechnical interlock and contactor.
Combination with same frame size only.
Distance between contactors: 15 mm
DILM185 – DILM500
DILM820-XMV
For two contactors with the same or different magnetic
systems.
Mechanical lifespan 5 x 106 operations. No auxiliary contact
is possible
between the mechnical interlock and contactor.
DILM820-XMV consists of interlock element and mounting
support plate.
DILM580 – DILM1000
Reversing Kits
MVS-WB-EM
Consisting of one 3-pole paralleling link with control
bridge and reversing link
with A2 bridge.
DILEM
(+MVDILEM)
DILM12-XRL
In addition to the electrical interlock, the following
control connections are
integrated:
• K1M: A1 – K2M: 21
• K1M: 21 – K2M: A1
• K1M: A2 – K2M: A1
DILM7/9/12 mains
DILM7/9/12 delta
DILM7/9/12 star
DILM32-XRL
DILM17/25/32 mains
DILM17/25/32 delta
DILM17/25/32 star
Star-Delta Wiring Kits
DILM12-XSL
The following control cables are integrated in addition to
electrical interlock:
• K3M: A1 – K5M: 21
• K3M: 21 – K5M: A1
• K3M: A2 – K5M: A1
DILM7/9/12 mains
DILM7/9/12 delta
DILM7/9/12 star
DILM32-XSL
DILM17/25/32 mains
DILM17/25/32 delta
DILM17/25/32 star
Paralleling Bridges (Consisting of two
paralleling links)
P1DILEM
4th pole can be broken off.
AC-1 current carrying capacity of the open contactor
increases by a factor of
2.5.
Protected against accidental contact (in accordance with IEC
536).
DILM12-XP1
4th pole can be broken off.
AC-1 current carrying capacity of the open contactor
increases by a factor of
2.5.
Protected against accidental contact (in accordance with IEC
536).
Terminal capacity can be found in the Technical Data
section.
3-pole
AC-1 current carrying capacity of the open Contactor
increases by a factor of
2.5.
A cover is included for protection against accidental
contact.
DILM185
Connection Tabs
BT483
1 x 6.3 x 0.8 or 2 x 2.8 x 0.8 mm
For auxiliary contact and coil connections.
Use connectors with insulated sleeves.
Standard quantity: 100
Must be ordered in standard quantity.
DILEM
DILM185 –
DILM1000
BT2571
DILM185 –
DILM1000
Terminal Blocks and Kits
Cable Terminal Blocks
DILM225-XKU-S
For cable connection. Single or double cables may be
connected.
See Technical Data for terminal capacity.
DILM185
DILM225
DILM400-XKU-S
DILM250 – DILM400
DILM500-XK-CNA
Consists of three individual terminals (Cu, Al), with
integrated control circuit
terminal. Terminal cover included.
Terminal capacity: 2 X (AWG4 to MCM500)
DILM500/22
DILM650-XK-CNA
Consists of three individual terminals (Cu, Al), with
integrated control circuit
terminal. Terminal cover included.
Terminal capacity: 2 X (AWG2 to MCM500)
DILM580/22
DILM650/22
DILM820-XK-CNA
Consists of three individual terminals (Cu, Al).
Terminal capacity: 4 X (AWG2 to MCM500)
DILM750/22
DILM820/22
Flat Strip Conductor Terminal Kit (with
Control Circuit Terminal consisting of 3 Flat Strip